Marine & Offshore Cables TEBAOFLEX

DFP-EO & DFP-EOB Dredger, Floating Pontoon & Barge Dynamic Power-Optical Umbilical Cable

DFP-EO and DFP-EOB dynamic dredger, floating pontoon and barge power-optical umbilical cables (0.6/1 kV to 3.6/6 kV, Um 7.2 kV) integrate IEC 60228 Class 5 tinned copper power cores (16 to 120 mm²), screened control pairs and 12 to 24 single-mode optical fibres inside aramid or galvanized steel-braid reinforced hydrolysis-resistant PUR/SHF2 double sheaths (29.5 to 55.0 mm OD, 10 to 12x OD dynamic bend).

Product information
SKU
TF-DFP-EO-DREDGER-UMB
Brand
TEBAOFLEX
Product overview

DFP-EO and DFP-EOB dynamic power-optical umbilical cables deliver continuous three-phase electric pump/winch power (0.6/1 kV, 3.3 kV and 6.6 kV), PLC/SCADA instrumentation pairs and 12 to 24 bend-insensitive optical fibres across cutter-suction dredgers (CSD), floating slurry discharge pipelines, Ro-Ro linkspan pontoons, floating drydocks and barge-to-shore wave crossovers (29.5 to 55.0 mm OD, 88 to 285 A).

Unlike rigid Class 2 shipboard cables that suffer strand fatigue across articulated pontoon hinges or bare steel-wire ROV lift cables that chafe polyurethane pipeline floats, DFP-EO assemblies lay fine-stranded ASTM B 33 / IEC 60228 Class 5 tinned copper conductors, 90 °C HEPR elastomer insulation, screened RS-485/Profibus/4–20 mA pairs and a gel-filled 316L stainless-steel FIMT around an elastomeric anti-buckling centre. An inner water-blocked elastomer sheath locked to a heavy slurry-grade polyether PUR (11Y) or SHF2 outer jacket via open-weave aramid braid (DFP-EO) or galvanized steel wire braid (DFP-EOB) prevents core corkscrewing under ±25 °/m multi-axis wave pitch and roll.

Specify DFP-EO when strapping composite power-optical runs along floating dredge pipelines with detachable closed-cell foam collars or hanging catenary loops between barges, Pontoons and quay walls; select DFP-EOB when cables cross crushed-rock decks or submerged cutter ladders. For 340 to 670 kN winch-lifted steel-armoured ROV/pontoon umbilicals see our RS726 & RS935 Umbilical & Deck Cable, or for 12/20 kV solar farm feeders see our NTSCGCWOEU Floating PV Shore Cable (MOQ 50 m, 7 to 45 working days).

Explore the marine, offshore and shipboard cable range for related configurations.

Construction

DFP-EO & DFP-EOB Dynamic Power-Optical Dredger & Pontoon Umbilical Construction

Every TEBAOFLEX DFP-EO and DFP-EOB composite umbilical is engineered with short-pitch torsion-balanced cabling, longitudinal water-blocking fillers and pressure-extruded inner/outer elastomer sheaths to withstand 24/7 wave flexing, saddle clamping and abrasive harbour silt.

Clean 2D engineering cross-section of DFP-EO dynamic dredger and pontoon power-optical umbilical cable showing outer heavy yellow PUR sheath, open-weave aramid reinforcement braid, black elastomeric inner sheath, outer ring of insulated tinned copper power conductors and central screened control pairs with laser-welded 316L stainless-steel FIMT optical unit
DFP-EO cross-section: symmetrical Class 5 HEPR power conductors, individually foil/braid-screened control pairs, 12–24SM stainless FIMT, inner elastomer bedding and PUR jacket.
DFP-EO & DFP-EOB Dredger, Floating Pontoon & Barge Dynamic Power-Optical Umbilical Cable construction
ComponentMaterial and construction
1. Flexible Tinned Copper Power Conductors (0.6/1 kV to 3.6/6 kV)Fine-stranded annealed tinned copper per IEC 60228 Class 5 and ASTM B 33 (16 mm² to 120 mm² phase cores plus full or split concentric earth conductors), insulated with 90 °C HEPR rubber (plus extruded inner/outer semiconducting screens and copper tape/wire earth screens on 3.3 kV and 6.6 kV builds).
2. Individually Screened Control & Instrumentation PairsTwo to six twisted pairs (1.0 mm² or 1.5 mm² Class 5 tinned copper, HEPR/EPR insulated) each shielded with tinned copper drain wire, 100% Al/PET tape and >= 85% tinned copper braid to isolate 4–20 mA dredge pressure transducers, gyrocompass and CAN/RS-485 loops from VFD switching noise.
3. Hermetic 316L Stainless-Steel Optical Unit (FIMT)Laser-welded 316L stainless-steel micro-tube (2.4 to 3.2 mm OD) filled with thixotropic water-blocking gel and over-sheathed with PE/TPEE to match control-unit pitch diameter, protecting 12 or 24 ITU-T G.657.A1 single-mode (or OM3 multimode) fibres against radial saddle clamping.
4. Water-Blocked Elastomeric Inner SheathHydrolysis-resistant cross-linked elastomer or thermoplastic inner bedding extruded under pressure into interstices with swelling yarns so jacket pinholes cannot wick seawater along the cable length.
5A. Anti-Torsion Aramid Braid + Heavy PUR / SHF2 Outer Jacket (DFP-EO)High-modulus open-weave aramid strength braid (18 to 60 kN dynamic pull rating, ±25 °/m torsion stability) embedded inside a tear-, mud-, oil- and UV-resistant high-visibility yellow or black polyether PUR (11Y per EN 50363-10-2) or SHF2 elastomer outer sheath.
5B. Galvanized Steel Wire Braid + Heavy PUR Over-Sheath (DFP-EOB)High-coverage (>= 85%) galvanized or tinned steel wire braid encapsulated beneath a 3.0 to 4.2 mm cut-resistant outer polyether PUR sheath for submerged dredge cutter ladders, spud-carriage loops and heavy deck vehicle crossovers.
TEBAOFLEX workshop macro sample photograph of heavy-duty composite marine power-control-optical umbilical cable resting on pure white background showing multi-core outer power conductors, central control/optical bundle and protective steel armour
TEBAOFLEX real workshop sample: multi-circuit power, central control/optical bundle and heavy marine armouring verified in production.

DFP-EO / DFP-EOB Model & Composite Core Code Breakdown

  • DFP-EO / DFP-EOB: Dredger, Floating Pontoon and Barge Electro-Optical dynamic umbilical with aramid anti-torsion braid (DFP-EO) or galvanized steel wire braid under outer PUR (DFP-EOB)
  • 1KV / 3.3KV / 6.6KV: power circuit rated voltage class: 0.6/1 (1.2) kV low voltage, 1.8/3.0 (3.3) kV or 3.6/6 (7.2) kV individually screened medium voltage
  • 4x35 / 3x70+1x35 / 3x50+3x25/3: flexible IEC 60228 Class 5 tinned copper phase and protective-earth conductor count and nominal cross-section in mm²
  • 4x2x1.0 / 6x2x1.0 / 4x2x1.5: individually Al/PET + tinned-copper-braid screened control and instrumentation twisted pairs for dredge sensors, RS-485 and PLC I/O
  • 12SM / 24SM (FIMT): 12 or 24 ITU-T G.657.A1 single-mode optical fibres hermetically housed inside a gel-filled laser-welded 316L stainless-steel micro-tube
Applications

DFP-EO Cutter-Suction Dredger, Floating Pipeline, Pontoon & Barge Applications

Deploy DFP-EO and DFP-EOB composite umbilicals across electric dredging spreads, modular floating pontoons, ship-repair drydocks and nearshore marine civil engineering barges.

Electric cutter-suction dredger and floating slurry discharge pipeline with high-visibility yellow DFP-EO composite power-optical umbilical cable clamped along floating pontoon collars across harbour water
Cutter-suction dredger and floating discharge pipeline routing heavy DFP-EO power-optical composite umbilical across collared pontoon floats.
  • Electric cutter-suction dredger (CSD) and floating booster-pump pipelines routing LV/MV power, slurry pressure/flow telemetry and gigabit PLC fibre across collared floating discharge pipes.
  • Articulated Ro-Ro linkspan pontoons, floating ferry terminals, link bridges and modular construction barges subject to continuous tidal heave and multi-axis wave sway.
  • Cutter-ladder gimbal loops, submerged dredge suction-head sonar/camera umbilicals and spud-pole carriage festoons requiring cut-resistant DFP-EOB braided protection.
  • Floating drydock-to-quay and accommodation-barge-to-platform dynamic catenary crossovers consolidating 400–690 V or 3.3–6.6 kV shore power and fibre-optic SCADA into a single umbilical.

DFP-EO Dynamic PUR Umbilical vs RS726 Steel-Armoured Winch Umbilical vs Floating PV Cable

DFP-EO Dredger/Pontoon Dynamic Umbilical vs RS726 Steel-Armoured ROV/Pontoon Umbilical vs NTSCGCWOEU Floating PV Cable
Cable FamilyVoltage & Core MakeupArmour & Outer JacketWhen to Specify
DFP-EO / DFP-EOB Dynamic Umbilical (this page)0.6/1 to 6.6 kV Class 5 Cu + screened pairs + 12–24SM FIMTAramid or GSWB braid inside thick slurry-grade PUR / SHF2Cutter-suction dredgers, floating pipelines, linkspan pontoons & barge crossovers
RS726 & RS935 ROV / Pontoon Winch Umbilical3.3 to 4.5 kV MV cores + control quad + 8–12SM FIMTBare contra-helical Zn-5Al steel wire armour (340–670 kN) or FMBPHigh-tension Lebus winch lifting, work-class ROVs & 1:1 41.0 mm spare drums
OMB Subsea Electro-Hydraulic Umbilical250 V to 3.3 kV electrical + FIMT + thermoplastic hosesAramid braid + hydrolysis-resistant PUR over hose bundleSubsea trenchers, ploughs & hydraulic cutter tools needing fluid power lines
NTSCGCWOEU Floating PV Shore Cable6/10 kV to 12/20 kV 3-core + split earth power onlyHeavy double rubber sheath (5GM5) without optical/control bundleMedium-voltage AC feeder runs from floating solar islands to shore substations

Select DFP-EO / DFP-EOB whenever abrasive slurry floats, articulated pontoon ramps or frequent wave flexing require an external elastomer/PUR jacket over fine-stranded Class 5 power + fibre cores.

DFP-EO & DFP-EOB Dredger & Floating Pontoon Umbilical RFQ Checklist

  • System power voltage (0.6/1 kV, 3.3 kV, 6.6 kV or 10 kV), three-phase motor/load current (A) and required phase + earth cross-section (mm²).
  • Control and instrumentation circuit count (for example 4x2x1.0 mm² or 6x2x1.5 mm² individually screened pairs for 4–20 mA, RS-485 or CAN).
  • Optical fibre count and mode (for example 12 or 24 ITU-T G.657.A1 single-mode or OM3 50/125 µm multimode fibres in 316L stainless FIMT).
  • Mechanical routing mode: strapped to floating dredge pipeline collars, free-hanging ship-to-pontoon catenary, submerged cutter ladder (DFP-EOB steel braid) or motorized reeling drum.
  • Outer diameter constraint (if matching existing pontoon glands, slip-ring boxes or float clamps), cut length per drum (MOQ 50 m) and target delivery schedule (7 to 45 working days).

Related selection resources

DFP-EO Dredger, Floating Pontoon & Barge Umbilical Frequently Asked Questions

Can DFP-EO umbilical cables float on water alongside a dredger discharge pipeline?

DFP-EO composite power-optical umbilicals have a specific gravity of 1.8 to 2.4 in air/water due to copper conductors, so they are engineered with a smooth, abrasion-resistant yellow polyether PUR jacket sized to clamp directly into standard split closed-cell PE/EVA pipeline buoyancy collars or strap onto floating slurry pontoons without jacket cutting.

When should I choose DFP-EOB galvanized steel-braided PUR over aramid-braided DFP-EO?

Specify DFP-EOB (galvanized steel wire braid under a 3.0 to 4.2 mm outer PUR jacket) whenever the umbilical runs down a submerged cutter-suction dredge ladder, crosses rock-strewn barge decks or faces pinch/crush hazards; choose lighter aramid-braided DFP-EO (10x OD dynamic bend radius) for long floating pipeline spans and wave-flexing pontoon hinges.

How are optical fibres protected against crushing in DFP-EO dredger and pontoon umbilicals?

12 or 24 bend-insensitive ITU-T G.657.A1 optical fibres are hermetically enclosed inside a laser-welded 316L stainless-steel tube (FIMT) filled with water-blocking gel and buffered with thermoplastic elastomer before cabling, preventing micro-bending attenuation under pipeline saddle clamps and ±25 °/m wave torsion.

Can TEBAOFLEX match an existing pontoon or dredger umbilical outer diameter for a 100 m to 500 m spare length?

Yes. TEBAOFLEX custom-engineers core layup, filler geometry and PUR/SHF2 wall thickness to match existing cable gland stuffing tubes, float saddle clamps and winch slip-ring entries within ±0.8 to 1.2 mm, with a minimum order quantity of 50 m and 7 to 45 working days production lead time.

Are 3.3 kV and 6.6 kV DFP-EO medium-voltage dredger umbilicals individually screened for VFD pump drives?

Yes. Every 1.8/3.0 (3.3) kV and 3.6/6 (7.2) kV DFP-EO phase conductor incorporates extruded semiconducting conductor and insulation screens plus a concentric tinned copper wire/tape metallic earth screen, while control pairs carry separate Al/PET + tinned copper braid shields for VFD EMC immunity.

Specifications

DFP-EO & DFP-EOB Dimensional, Ampacity, Bend-Radius & Pulling-Load Schedule

DFP-EO & DFP-EOB Key Voltage, Composite Core, Sheath & Supply Summary

  • LV & MV composite power range: 0.6/1 kV, 1.8/3.0 (3.3) kV and 3.6/6 (7.2) kV flexible Class 5 tinned copper cores from 4x16 mm² up to 3x120+1x70 mm²
  • Integrated PLC & optical telemetry: 2 to 6 individually Al/PET + tinned-copper-braid screened control pairs (1.0–1.5 mm²) plus 12 or 24 ITU-T G.657.A1 single-mode fibres in 316L FIMT
  • Wave-flexing & slurry durability: Double-extruded polyether PUR (11Y) or cross-linked SHF2 outer sheath resisting sand/mud slurry abrasion, diesel splash, UV and ±25 °/m roll torsion
  • Two reinforcement architectures: Open-weave aramid anti-torsion braid (DFP-EO, 18 to 60 kN) for floating pipeline catenaries or galvanized steel wire braid under PUR (DFP-EOB) for deck/ladder crush
  • Short-run & exact-OD supply: Minimum order quantity 50 m (including 100 to 600 m pontoon jumpers and floating pipeline spans) manufactured in 7 to 45 working days
DFP-EO & DFP-EOB Dredger, Floating Pontoon & Barge Dynamic Power-Optical Umbilical Cable technical data
ParameterValue
Rated voltage0.6/1 kV (Um 1.2 kV), 1.8/3.0 kV (Um 3.3 kV) and 3.6/6 kV (Um 7.2 kV) AC power cores with 250 V screened control pairs
Composite core architecture3 or 4 Class 5 tinned copper power cores (16 to 120 mm²) plus 2 to 6 screened control pairs and 12 or 24 G.657.A1 optical fibres in 316L FIMT
Reinforcement and outer sheathAramid anti-torsion braid (DFP-EO) or galvanized steel wire braid (DFP-EOB) inside heavy hydrolysis- and slurry-resistant polyether PUR or SHF2 sheath
Outer diameter and tensile rating29.5 mm to 55.0 mm nominal outer diameter with 18 kN to 60 kN maximum dynamic pulling load and plus or minus 25 deg/m torsion limit
Dynamic bend radius and supply10x OD (DFP-EO) or 12x OD (DFP-EOB) minimum dynamic bend radius with MOQ 50 m and 7 to 45 working days manufacturing lead time
Operating temperature and water depth-40 °C to +90 °C conductor temperature (-35 °C to +80 °C flexing in water/slurry), continuous submergence rated to 100 m (1.0 MPa)
Optical attenuation and HV test<= 0.38 dB/km at 1310 nm and <= 0.25 dB/km at 1550 nm (ITU-T G.657.A1); 3.5 kV AC (0.6/1 kV), 6.5 kV AC (3.3 kV) or 11 kV AC (6.6 kV) 5 min routine test

DFP-EO & DFP-EOB Dynamic Dredger & Pontoon Umbilical Dimensional & Ampacity Schedule

DFP-EO & DFP-EOB Dredger, Floating Pontoon & Barge Dynamic Power-Optical Umbilical — Dimensional, Ampacity & Mechanical Schedule
Model & Composite ConfigurationRated Voltage (kV)Nominal OD (mm)Reinforcement & SheathCurrent at 30 °C Air (A)Weight in Air (kg/km)Min. Dynamic Bend | Max. Pull (mm | kN)Next step
DFP-EO-1KV 4x16+4x2x1.0+12SM0.6/1 (1.2)29.5 ± 1.0Aramid Braid + Heavy PUR (11Y)881380295 | 18.0Request this size
DFP-EOB-1KV 4x25+4x2x1.0+12SM0.6/1 (1.2)35.2 ± 1.0Galv. Steel Braid + Outer PUR1102460425 | 35.0Request this size
DFP-EO-1KV 4x35+6x2x1.0+12SM0.6/1 (1.2)36.8 ± 1.0Aramid Braid + Heavy PUR (11Y)1382390370 | 28.0Request this size
DFP-EO-1KV 3x70+1x35+4x2x1.5+12SM0.6/1 (1.2)44.5 ± 1.2Aramid Braid + Slurry PUR (11Y)2073920445 | 42.0Request this size
DFP-EO-1KV 3x120+1x70+4x2x1.5+24SM0.6/1 (1.2)55.0 ± 1.5Aramid Braid + Heavy PUR / SHF22856340550 | 60.0Request this size
DFP-EO-3.3KV 3x35+3x16/3+2x2x1.0+12SM1.8/3.0 (3.3)43.0 ± 1.2MV Screen + Aramid + Heavy PUR1353480520 | 40.0Request this size
DFP-EO-6.6KV 3x50+3x25/3+2x2x1.5+12SM3.6/6 (7.2)49.5 ± 1.5MV Screen + Aramid + PUR / SHF21684650600 | 52.0Request this size

DFP-EO Sheath, Steel-Braid & Floating-Pipeline Deployment Options

DFP-EO & DFP-EOB Outer Sheath, Braid & Buoyancy Collar Engineering Options
Option CodeJacket / Protection ArchitectureAbrasion, Oil & Mud RatingBuoyancy / Deployment ModeTypical Dredge & Pontoon Duty
DFP-EO-PUR (Standard)Inner elastomer + open aramid braid + polyether PUR (11Y)EN 50363-10-2 tear/slurry abrasion & hydrolysis resistantSinking catenary or strapped to pipeline floatsFloating discharge pipelines, Ro-Ro linkspans & barge hinges
DFP-EO-SHF2Inner HEPR bedding + aramid braid + cross-linked SHF2IEC 60092-360 SHF2 oil, drilling-fluid & flame retardantDeck tray, catenary loop or splash-zone hangerFloating drydocks, accommodation barges & port link bridges
DFP-EOB-PUR (Armoured)Inner elastomer + >= 85% GSWB steel braid + thick PURHigh radial crush, rock impact & dredge ladder cut protectionSubmerged ladder gimbal or deck vehicle rampCutter-suction dredge ladders, spud carriages & rock barges
DFP-EO-FLT (Float-Ready)Smooth low-friction yellow PUR calibrated for split foam collarsUV-stabilized high-visibility marine yellow outer jacketSurface self-floating via clamped PE/EVA collarsShip-to-shore dredge slurry lines & modular booster pontoons

Continuous current ratings are reference values at 30 °C ambient air (IEC 60092-352 / DIN VDE 0298-4 basis for three loaded phase conductors); apply standard derating for multi-layer reeling drums or solar-exposed deck trays, and final values are confirmed on the quotation drawing.

Custom composite layouts (including 6/10 kV MV cores, OM3/OM4 multimode fibres, Cat6A industrial Ethernet quads and exact outer-diameter matching within ±0.8–1.2 mm to fit existing saddle clamps or slip-ring glands) are engineered to order.

Minimum order quantity is 50 m with a production lead time of 7 to 45 working days, delivered on export-grade wooden or steel drums with factory HV dielectric and OTDR trace reports.

ASCII part references for BOM and ERP entry: DFP-EO-1KV-4X16-12SM; DFP-EOB-1KV-4X25-12SM; DFP-EO-1KV-4X35-12SM; DFP-EO-1KV-3X70-1X35-12SM; DFP-EO-1KV-3X120-1X70-24SM; DFP-EO-3.3KV-3X35-12SM; DFP-EO-6.6KV-3X50-12SM; TF-DFP-EO-DREDGER-UMB.

Standards

DFP-EO Marine Conductor, Elastomer Sheath & Optical Fibre Standards

DFP-EO & DFP-EOB Dredger, Floating Pontoon & Barge Dynamic Power-Optical Umbilical Cable standards and test references
Standard or specificationApplication
IEC 60228 Class 5 & ASTM B 33Fine-stranded annealed tinned copper conductors engineered for multi-million-cycle wave flexing and corrosion resistance in brackish and marine atmospheres.
IEC 60092-350 / IEC 60092-353 / IEC 60092-360Offshore and marine electrical core design, 90 °C HEPR insulation thickness schedule and SHF2 cross-linked elastomeric sheathing reference.
EN 50363-10-2 / DIN VDE 0282-10 (11Y Polyether PUR)Heavy-duty hydrolysis-, microbe-, sand-slurry- and tear-resistant polyurethane outer sheath specification for wet dynamic trailing and floating cables.
ITU-T G.657.A1 & Laser-Welded 316L FIMTBend-insensitive single-mode optical fibres housed in gel-filled stainless-steel micro-tubes maintaining <= 0.38 / 0.25 dB/km attenuation at 1310 / 1550 nm under dynamic bending.

Certifications and document support

TEBAOFLEX ISO 9001 quality management, HV AC/DC dielectric and OTDR optical test documentation

ISO 13628-5 — Design, material and factory verification reference for marine electro-optical umbilicals

IEC 60092-353 — Electrical installations in ships and offshore units: 1 kV and 3 kV power cable design

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.