Double-Insulated PVC/NBR (1,000 V SANS 1507 & 300/500 V) & 750 V Hi-Flex PVC Welding Cable (1.5–400 mm²)
Double-Insulated PVC/NBR & Hi-Flex PVC Welding Cable combines rugged thermoplastic primary insulation with oil- and water-resistant PVC/nitrile rubber (NBR) blend outer sheathing across 1.5 mm² to 400 mm². Engineered in three distinct duty tiers—1,000 V SANS 1507-3 power-and-welding builds (6,000 V AC test), HD 22.6 0.20 mm extra-flexible dual-mode builds (100 V / 90 °C welding or 300/500 V / 70 °C power), and 750 V indoor Hi-Flex PVC—it serves African mining switchboards, borehole pump cubicles and shop-floor welders.
Double-Insulated PVC/NBR & 750 V Hi-Flex PVC Welding Cable addresses high-volume industrial projects where standard single-layer rubber leads lack 1,000 V panel dielectric strength, while rigid Class 2 PVC house wires are too stiff to pull through tight switchboard ducts, transformer cubicles, borehole pump shafts and mobile welding bays.
In Southern African mining and heavy industrial electrical installations governed by SANS 1507-3, our 1,000 V Double-Insulated Power & Welding Cable extrudes a general-purpose PVC primary insulation bedding beneath a tightly bonded, water- and oil-resistant PVC/nitrile rubber (NBR) blend outer sheath—tested at 6,000 V AC across 16 mm² to 185 mm² in bare or tinned Class 5 copper. Where handheld welding torches demand finer 0.20 mm wire stranding, our HD 22.6-based Double-Insulated PVC/NBR Series spans 1.5 mm² right up to 400 mm² (up to 11,644 × 0.20 mm strands), operating at +90 °C / 100 V as a welding lead or +70 °C / 300/500 V as a portable power lead. For dry, protected indoor welding benches and conduit runs away from hot metal contact, a 750 V 70 °C Hi-Flex single-layer PVC build (0.30 mm strands, 16–120 mm²) provides an economical alternative.
Important thermal boundary: thermoplastic PVC and PVC/NBR blends soften if laid directly across red-hot weldments or molten slag—where hot workpiece contact or -40 °C arctic flexing occurs, select cross-linked thermoset rubber (`H01N2-D/E`, `60245 IEC 82 YHF` or `Class K/M EPDM/CPE`). Bulk drum MOQ 300 m; lead time 7 to 45 working days.
Explore the welding cable range for related configurations.
Double-Insulated PVC/NBR & Hi-Flex PVC Construction
Engineered across three clearly separated thermoplastic/nitrile-blend constructions so dielectric test voltage, strand diameter and thermal limits match the exact installation.

| Component | Material and construction |
|---|---|
| 1. Flexible Bunched Annealed Copper Conductor | SANS 1507-3 1 kV Series: Class 5 bare or tinned copper (0.41 / 0.501 mm strands). HD 22.6 Extra-Flex Series: 0.20 mm fine copper wires. 750 V Hi-Flex PVC: 0.30 mm bare copper wires. |
| 2. Primary PVC Dielectric Insulation Layer | Extruded PVC primary bedding on SANS 1507-3 (1,000 V rated, 6,000 V test) and extra-flexible NBR-modified PVC inner insulation (1.0–2.4 mm wall) on HD 22.6 builds. |
| 3. Tightly Bonded PVC / Nitrile Rubber (NBR) Outer Sheath | Oil-, water- and abrasion-resistant nitrile-rubber/PVC blend outer sheath in royal blue, black, red or white providing mechanical cut and visual damage indication. |
| 4. 750 V Single-Layer Hi-Flex PVC Option (Dry Indoor Only) | Single-extrusion flexible 70 °C PVC covering (black or red, IEC 60332-1-2 flame retardant) strictly for dry indoor bench/piping service away from thermal radiation. |
Double-Insulated SANS 1507 & PVC/NBR Code Guide
- SANS 1507-3 (1,000 V / 6 kV Test): South African National Standard specification for 600/1,000 V PVC-insulated electric cables, widely used for flexible panel/welding PVC-NBR cables
- PVC / NBR (Nitrile Blend): Thermoplastic elastomer blend combining PVC flame/dielectric stability with nitrile rubber (NBR) mineral-oil resistance and cold suppleness
- Dual-Mode HD 22.6 PVC/NBR: Rated 100 V at +90 °C max conductor temp in secondary arc-welding duty, or 300/500 V at +70 °C in flexible power transmission
- Double-Insulated Wear Indicator: Contrasting inner PVC bedding color beneath the outer PVC/NBR sheath immediately reveals deep mechanical cuts during safety inspection
- Thermal Contact Boundary: Unlike cross-linked thermoset rubber (250 °C short-circuit), thermoplastic PVC/NBR must be routed clear of hot workpieces and radiant heat
Double-Insulated PVC/NBR Welding & Switchboard Applications
Tailored for dual switchboard/power wiring and oil-exposed fabrication welding where double-insulated dielectric protection and easy duct pulling are prioritized.

- 1,000 V flexible internal and external switchboard bus drops, transformer tails, confined-space trunking, mine shaft ducts and large borehole pump feeders (SANS 1507-3 build).
- Heavy-duty indoor/outdoor workshop arc-welding leads exposed to cutting oils, water washdown and concrete floor dragging (PVC/NBR double-insulated builds).
- Portable generator, motor and welding-rectifier secondary leads requiring fine 0.20 mm extra-flexible stranding from 1.5 mm² to 400 mm².
- Dry indoor bench welding and embedded-conduit battery/DC power connections away from hot metal contact (750 V Hi-Flex PVC build).
- Bulk drum supply (MOQ 300 m) with sequential 1 m marking and optional custom cold-crimped copper lugs per terminal drawing.
Double-Insulated PVC/NBR vs. Hi-Flex PVC vs. Rubber Comparison
| Cable Construction | Rated / Test Voltage | Hot-Spatter Resistance | Oil & Water Resistance | Ideal Deployment |
|---|---|---|---|---|
| 1,000 V SANS 1507-3 PVC/NBR | 1,000 V / 6,000 V AC | Moderate (avoid hot metal) | High (bonded nitrile blend) | Switchboards, borehole pumps & general shop welding |
| HD 22.6 0.20 mm Double PVC/NBR | 100 V Weld / 300/500 V | Moderate (thermoplastic) | High (dual PVC/NBR layers) | Extra-limp portable welder & generator leads (1.5–400 mm²) |
| 750 V Single-Layer Hi-Flex PVC | 750 V | Low (dry indoor only) | Splash only (not wet burial) | Protected indoor bench welders, piping & battery racks |
| H01N2-D / H01N2-E EM5 Rubber (WC 3465) | 100/100 V / 1,000 V | Very high (+250 °C short-circuit) | High (cross-linked EM5) | Heavy shipyard/foundry welding near hot steel & -40 °C cold |
Thermoplastic PVC and PVC/NBR compounds melt if pressed against hot weld seams; always specify cross-linked thermoset rubber (H01N2-D/E, 0361TQ or Class K/M EPDM/CPE) where hot metal contact is unavoidable.
Double-Insulated PVC/NBR Welding Cable RFQ Checklist
- Target construction tier: 1,000 V SANS 1507-3 PVC/NBR (Class 5), HD 22.6 0.20 mm extra-flexible double PVC/NBR, or 750 V single-layer Hi-Flex PVC.
- Conductor cross-section (1.5 mm² to 400 mm²) and bare vs. tinned copper finish.
- Outer sheath color (royal blue, black, red or white) and contrasting inner insulation color preference.
- Order meterage per size (standard bulk drum/coil MOQ 300 m; lead time 7 to 45 working days).
- Optional custom cold-crimped copper lug specifications per terminal drawing.
Related selection resources
- Industrial & Custom Welding Cable Supplier Hub
- Rubber Cable vs. PVC Cable: Thermal, Spatter & Oil Selection Guide
- AS/NZS 1995 & 5000.1 0.6/1 kV XLPE/TPE & 110 °C LSZH Cable
- H01N2-D / H01N2-E Cross-Linked EM5 Rubber Welding Cable
- Welding Cable Size Chart: Amperage, Length & Duty Cycle
Double-Insulated PVC/NBR & Hi-Flex PVC Cable FAQ
Why do mines and switchboard builders specify 1,000 V SANS 1507-3 double-insulated PVC/NBR cable?
1,000 V rated voltage (backed by a 6,000 V AC test) and a tightly bonded oil- and water-resistant PVC/nitrile rubber (NBR) outer sheath allow one flexible single-core cable to replace rigid house wire in switchboards, ducts and borehole pumps while also serving harsh shop welding bays.
Can Double-Insulated PVC/NBR or 750 V Hi-Flex PVC welding cable touch hot welded steel?
No. Unlike cross-linked thermoset rubber (EM5, EPDM or CPE) that withstands +250 °C short-circuit heat without melting, thermoplastic PVC and PVC/NBR soften under direct thermal radiation or hot metal contact and must be routed clear of hot workpieces.
What does dual-rated 100 V / +90 °C and 300/500 V / +70 °C mean on the HD 22.6 PVC/NBR cable?
100 V at up to +90 °C conductor temperature applies during intermittent secondary arc-welding dutycycles, whereas 300/500 V at +70 °C continuous conductor temperature applies when the same cable is used for continuous portable power transmission.
Is tinned copper available on the 1,000 V SANS 1507-3 double-insulated PVC/NBR cable?
Yes. Both high-conductivity bare annealed copper and corrosion-resistant tinned copper conductors are manufactured across 16 mm² to 185 mm² for humid mine shafts, coastal panels and borehole pump cubicles.
What is the MOQ and lead time for Double-Insulated PVC/NBR welding cable?
300 m per cross-section and sheath color is our standard bulk drum MOQ with a 7 to 45 working days manufacturing lead time, and matched cold-crimped copper lugs can be supplied to your drawing.
Double-Insulated PVC/NBR Technical Specifications
Double-Insulated PVC/NBR Key Engineering Highlights
- 1,000 V SANS 1507-3 PVC + PVC/Nitrile (NBR) build: PVC primary bedding + tightly bonded oil/water-resistant PVC/NBR blend sheath (6,000 V AC test, 16–185 mm²) for harsh welding, switchboards and borehole pumps
- HD 22.6 0.20 mm extra-flexible double PVC/NBR: Hair-fine 0.20 mm copper stranding (1.5–400 mm²) dual-rated 100 V / +90 °C for arc welding and 300/500 V / +70 °C for portable generator/motor connections
- 750 V indoor Hi-Flex PVC shop-bench option: Cost-effective 0.30 mm bunched copper single-layer 70 °C PVC lead (16–120 mm², 6 × D bend) for dry indoor conduit, bench welders and battery racks
- Bare or tinned copper & sequential meter marks: Available with high-conductivity bare or tinned copper in blue, black, red or white sheaths with 1 m sequential length marking
- 300 m bulk MOQ & matched copper lugs: Supplied in 300 m minimum bulk drums/coils (7 to 45 working days) with optional custom cold-crimped copper lugs per buyer drawing
| Parameter | Value |
|---|---|
| Rated voltage | 1,000 V AC (6,000 V test) on SANS 1507-3 PVC/NBR; 100 V welding or 300/500 V power on HD 22.6 PVC/NBR; 750 V on indoor Hi-Flex PVC |
| Operating temperature range | -10 °C to +80 °C on 1,000 V SANS 1507-3 PVC/NBR; up to +90 °C (welding) / +70 °C (power) on HD 22.6 PVC/NBR; +70 °C on 750 V Hi-Flex PVC |
| Conductor stranding | High-conductivity annealed copper (bare or tinned): Class 5 (0.41/0.50 mm), extra-fine 0.20 mm (42 to 11,644 strands), or 0.30 mm Hi-Flex |
| Insulation and sheath | Two-layer PVC primary insulation + bonded oil/water-resistant PVC/nitrile (NBR) outer sheath (or single-layer 750 V flexible PVC) |
| Minimum bending radius | 6 × overall cable diameter with flame retardance to IEC 60332-1-2; route clear of hot weldments and direct thermal radiation |
| Minimum order and lead time | 300 m minimum order quantity per size and color; custom manufacturing lead time 7 to 45 working days (cold-crimped copper lugs optional) |
Double-Insulated 1,000 V SANS 1507-3 PVC/NBR Power & Welding Schedule
| Model & Size (mm²) | Class 5 Stranding (No. × mm) | Nominal OD (mm) | Approx. Weight (kg/km) | Cubicle 1-Ph 220V (A) | Cubicle 3-Ph 380V (A) | Test Voltage | Bulk MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| Double-Insulated SANS 1kV 1×16 | 120 × 0.41 | 9.4 | 219 | 76 | 68 | 6,000 V AC | 300 m | Request this size |
| Double-Insulated SANS 1kV 1×25 | 180 × 0.41 | 10.4 | 303 | 101 | 89 | 6,000 V AC | 300 m | Request this size |
| Double-Insulated SANS 1kV 1×35 | 252 × 0.41 | 11.8 | 414 | 125 | 110 | 6,000 V AC | 300 m | Request this size |
| Double-Insulated SANS 1kV 1×50 | 366 × 0.41 | 14.4 | 599 | 151 | 134 | 6,000 V AC | 300 m | Request this size |
| Double-Insulated SANS 1kV 1×70 | 516 × 0.41 | 17.1 | 830 | 192 | 171 | 6,000 V AC | 300 m | Request this size |
| Double-Insulated SANS 1kV 1×95 | 456 × 0.50 | 18.6 | 1071 | 232 | 207 | 6,000 V AC | 300 m | Request this size |
| Double-Insulated SANS 1kV 1×120 | 582 × 0.50 | 21.3 | 1369 | 269 | 239 | 6,000 V AC | 300 m | Request this size |
| Double-Insulated SANS 1kV 1×150 | 762 × 0.50 | 24.7 | 1793 | 300 | 262 | 6,000 V AC | 300 m | Request this size |
| Double-Insulated SANS 1kV 1×185 | 924 × 0.50 | 26.8 | 2201 | 341 | 296 | 6,000 V AC | 300 m | Request this size |
Double-Insulated 0.20 mm PVC/NBR (HD 22.6) & 750 V Hi-Flex PVC Schedule
| Model & Size (mm²) | Copper Stranding (No. × mm) | Inner / Outer Wall (mm) | Approx. OD (mm) | Approx. Weight (kg/km) | Voltage / Temp Rating | Bulk MOQ | Next step |
|---|---|---|---|---|---|---|---|
| Double-Insulated PVC/NBR 1×6 | 176 × 0.20 | 1.0 / 1.0 | 7.2 | 96 | 100V 90°C Weld / 500V 70°C | 300 m | Request this size |
| Double-Insulated PVC/NBR 1×10 | 294 × 0.20 | 1.0 / 1.4 | 8.9 | 156 | 100V 90°C Weld / 500V 70°C | 300 m | Request this size |
| Double-Insulated PVC/NBR 1×16 | 490 × 0.20 | 1.0 / 1.4 | 10.1 | 225 | 100V 90°C Weld / 500V 70°C | 300 m | Request this size |
| Double-Insulated PVC/NBR 1×25 | 722 × 0.20 | 1.2 / 1.4 | 11.7 | 314 | 100V 90°C Weld / 500V 70°C | 300 m | Request this size |
| Double-Insulated PVC/NBR 1×35 | 1050 × 0.20 | 1.2 / 1.4 | 12.6 | 418 | 100V 90°C Weld / 500V 70°C | 300 m | Request this size |
| Double-Insulated PVC/NBR 1×50 | 1420 × 0.20 | 1.4 / 1.6 | 14.8 | 566 | 100V 90°C Weld / 500V 70°C | 300 m | Request this size |
| Double-Insulated PVC/NBR 1×70 | 2130 × 0.20 | 1.4 / 1.8 | 17.0 | 808 | 100V 90°C Weld / 500V 70°C | 300 m | Request this size |
| Double-Insulated PVC/NBR 1×95 | 2698 × 0.20 | 1.6 / 2.0 | 19.5 | 1045 | 100V 90°C Weld / 500V 70°C | 300 m | Request this size |
| Double-Insulated PVC/NBR 1×120 | 3550 × 0.20 | 1.6 / 2.0 | 21.3 | 1321 | 100V 90°C Weld / 500V 70°C | 300 m | Request this size |
| Double-Insulated PVC/NBR 1×185 | 5254 × 0.20 | 2.0 / 2.6 | 26.3 | 2009 | 100V 90°C Weld / 500V 70°C | 300 m | Request this size |
| Double-Insulated PVC/NBR 1×240 | 6958 × 0.20 | 2.2 / 2.8 | 31.1 | 2652 | 100V 90°C Weld / 500V 70°C | 300 m | Request this size |
| Double-Insulated Hi-Flex PVC 1×35 | 444 × 0.30 | 1.7 (Single PVC) | 12.0 | 410 | 750 V / 70 °C Dry Indoor | 300 m | Request this size |
| Double-Insulated Hi-Flex PVC 1×50 | 636 × 0.30 | 1.7 (Single PVC) | 13.8 | 565 | 750 V / 70 °C Dry Indoor | 300 m | Request this size |
| Double-Insulated Hi-Flex PVC 1×70 | 900 × 0.30 | 1.9 (Single PVC) | 15.9 | 780 | 750 V / 70 °C Dry Indoor | 300 m | Request this size |
Additional HD 22.6 extra-flexible PVC/NBR sizes (1.5, 2.5, 4, 150, 300 and 400 mm²) and 750 V Hi-Flex PVC sizes (16, 25, 95 and 120 mm²) are manufactured to order on identical 300 m MOQ terms.
Safety note: 750 V single-layer Hi-Flex PVC is restricted to dry indoor or conduit routing and must never contact hot metal parts, molten spatter or direct burial.
ASCII part references for BOM and ERP entry: TF-SANS1507-PVCNBR-16, TF-SANS1507-PVCNBR-25, TF-SANS1507-PVCNBR-35, TF-SANS1507-PVCNBR-50, TF-SANS1507-PVCNBR-70, TF-SANS1507-PVCNBR-95, TF-SANS1507-PVCNBR-120, TF-SANS1507-PVCNBR-150, TF-SANS1507-PVCNBR-185, TF-HD226-PVCNBR-35, TF-HD226-PVCNBR-50, TF-HD226-PVCNBR-70, TF-HIFLEX-PVC-35, TF-HIFLEX-PVC-50.
Double-Insulated PVC/NBR Standards & Test References
| Standard or specification | Application |
|---|---|
| SANS 1507-3 | South African specification reference for 600/1,000 V PVC-insulated power and panel cables with 6,000 V AC dielectric test. |
| CENELEC HD 22.6 / IEC 60245-6 Reference | Fine-stranded 0.20 mm copper conductor construction reference for extra-flexible double-insulated PVC/NBR welding leads. |
| IEC 60228 (Class 5 & Class 6) | Flexible and extra-flexible annealed copper conductor stranding and DC resistance limits. |
| IEC 60332-1-2 | Vertical flame-propagation test for single insulated conductors and cables. |
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
AS/NZS 1995 & AS/NZS 5000.1 0.6/1 kV Double-Insulated Welding & Flexible Power Cable (10–630 mm²)
A related cable option for a different application or duty profile.
View productIndustrial Welding Cable 600 V–1 kV — EPDM, EPR, NTC 6078 TPE, CPE & Fabric-Served TSE
A related cable option for a different application or duty profile.
View productH01N2-D & H01N2-E (NSLFFÖU) 100/100 V Rubber Arc Welding Cable (EN 50525-2-81, 10–240 mm²)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.