AS/NZS 1995 & AS/NZS 5000.1 0.6/1 kV Double-Insulated Welding & Flexible Power Cable (10–630 mm²)
AS/NZS 1995 & AS/NZS 5000.1 0.6/1 kV Welding & Flexible Power Cable is the dual-standard Australian and New Zealand double-insulated single-core copper cable spanning 10 mm² to 630 mm². Available in 90 °C X-90 XLPE / TPE-90 heavy-duty elastomer and 110 °C X-HF-110 / HFS-110-TP low-smoke zero-halogen (AS/NZS 4507 RHE flame-retardant) builds, it serves both high-current arc-welding leads and 0.6/1 kV flexible switchboard, generator and mine distribution feeders.
AS/NZS 1995 & AS/NZS 5000.1 0.6/1 kV Double-Insulated Welding & Flexible Power Cable solves a critical compliance requirement across Australian and New Zealand mines, shipyards, infrastructure tunnels and heavy switchboard builders: single-layer 100 V welding cables cannot be used in 0.6/1 kV power circuits, while stiff Class 2 building wires cannot survive welding-bay flexing or tight cabinet bends.
By extruding a primary cross-linked dielectric inner layer beneath a separate heavy-duty abrasion- and oil-resistant outer sheath over fine-stranded annealed copper (10 mm² right up to 630 mm²), this dual-rated architecture satisfies both AS/NZS 1995 (welding cables) and AS/NZS 5000.1 (0.6/1 kV electric power cables). Two distinct thermal and fire-safety tiers are available: the 90 °C industrial workhorse pairs X-90 cross-linked polyethylene insulation with a tough TPE-90 thermoplastic elastomer sheath, whereas the 110 °C low-smoke zero-halogen tier pairs X-HF-110 cross-linked LSZH insulation with an HFS-110-TP heavy-metal-free sheath engineered to AS/NZS 4507 RHE reduced-fire-hazard performance for confined tunnels, underground coal/metalliferous workshops, naval drydocks and data-center/substation bus drops.
Specify the 90 °C X-90/TPE-90 build for general heavy fabrication, quarry generators and mobile welders, or upgrade to the 110 °C X-HF-110/HFS-110-TP LSZH build where halogen-free smoke toxicity and 110 °C thermal headroom are mandatory. Supplied on export drums (MOQ 300 m, lead time 7 to 45 working days) with optional custom cold-crimped copper lugs per terminal drawing.
Explore the welding cable range for related configurations.
AS/NZS 1995 & 5000.1 0.6/1 kV Cable Construction
Concentric two-layer 0.6/1 kV double-insulated flexible single-core construction engineered to AS/NZS 1995 and AS/NZS 5000.1 in 90 °C XLPE/TPE and 110 °C LSZH RHE compound systems.

| Component | Material and construction |
|---|---|
| 1. Fine-Stranded Flexible Annealed Copper Conductor | High-conductivity plain copper (tinned optional): max wire Ø 0.21 mm (10–35 mm²), 0.31 mm (50–95 mm²) and 0.51 mm (120–630 mm²) per AS/NZS 1125. |
| 2. Primary Cross-Linked 0.6/1 kV Dielectric Insulation | Option A: X-90 cross-linked polyethylene (90 °C continuous). Option B: X-HF-110 cross-linked low-smoke zero-halogen compound (110 °C continuous, lead- & antimony-free). |
| 3. Heavy-Duty Flexible Outer Sheath | Option A: TPE-90 oil-, UV- and abrasion-resistant elastomer sheath. Option B: HFS-110-TP flame-retardant LSZH thermoplastic sheath per AS/NZS 3808 / AS/NZS 4507 RHE. |
| 4. Sheath Color Identification | Supplied in high-visibility orange or black as standard; red, blue, white and green/yellow earth sheaths available to order. |
AS/NZS 1995, X-90/TPE-90 & 110 °C LSZH Code Guide
- AS/NZS 1995: Australian/New Zealand standard for welding cables, governing mechanical toughness and 10-minute / 5-minute duty-cycle current ratings
- AS/NZS 5000.1 (0.6/1 kV): Low-voltage electric cable standard up to 0.6/1 kV, enabling legal dual use in flexible switchboard, generator, transformer and VSD feeder circuits
- X-90 / TPE-90 (90 °C Grade): 90 °C cross-linked polyethylene insulation paired with 90 °C thermoplastic elastomer outer sheathing
- X-HF-110 / HFS-110-TP (110 °C LSZH): 110 °C halogen-free cross-linked insulation and 110 °C LSZH sheath free of halogens, lead and antimony
- AS/NZS 4507 RHE: Reduced-fire-hazard classification covering flame propagation, low smoke density and zero halogen acid gas emission
AS/NZS 1995 Welding & 0.6/1 kV Power Applications
Dual-qualified for high-current arc-welding leads and 0.6/1 kV flexible low-voltage power interconnections across Australia, New Zealand and Asia-Pacific mining/marine projects.

- Heavy-duty electrode and earth-return arc-welding leads in mine maintenance workshops, structural steel yards, shipyards and offshore fabrication pads.
- 0.6/1 kV flexible single-core busbar drops, transformer tails, generator load-bank leads, motor leads and high-density switchboard internal/inter-panel wiring.
- Confined-space tunnel boring, underground mining bays, naval vessels and substation battery/UPS rooms requiring 110 °C X-HF-110 / HFS-110-TP LSZH safety.
- Earthing and equipotential bonding jumpers (green/yellow sheath option) requiring fine-stranded vibration resistance.
- Bulk drum supply (MOQ 300 m) with optional custom cold-crimped bell-mouth copper lugs matched to Australian/metric stud sizes.
AS/NZS 1995 90 °C vs. 110 °C LSZH vs. H01N2 Comparison
| Construction Variant | Rated Voltage | Insulation + Sheath | Max Conductor Temp | Target Site & Compliance |
|---|---|---|---|---|
| AS/NZS 1995 + 5000.1 (90 °C Grade) | 0.6/1 kV | X-90 XLPE + TPE-90 | +90 °C | AU/NZ fabrication shops, switchboards & mobile welders |
| AS/NZS 1995 + 5000.1 (110 °C LSZH) | 0.6/1 kV | X-HF-110 + HFS-110-TP LSZH | +110 °C | Underground mines, tunnels, naval docks & substation rooms |
| SANS 1507-3 Double-Insulated (NW5) | 1,000 V | PVC + PVC/Nitrile (NBR) | +80 °C | African mining switchboards, borehole pumps & harsh welding |
| H01N2-D / H01N2-E (WC 3465) | 100/100 V | Single-layer EM5 rubber | +85 °C | Dedicated 100 V European arc-welding leads (not for 1 kV power) |
Unlike European H01N2-D (100/100 V), AS/NZS 1995 / 5000.1 cables incorporate full 0.6/1 kV X-90 or X-HF-110 primary dielectric insulation beneath the outer sheath, allowing dual deployment in 415 V / 1,000 V low-voltage power panels.
AS/NZS 1995 & 5000.1 0.6/1 kV Cable RFQ Checklist
- Compound tier selection: 90 °C X-90 XLPE / TPE-90 standard elastomer vs. 110 °C X-HF-110 / HFS-110-TP low-smoke zero-halogen (AS/NZS 4507 RHE).
- Conductor cross-section (10 mm² through 630 mm²) and bare vs. tinned copper preference.
- Outer sheath color (orange, black, green/yellow earth, red, blue or white).
- Application mode (AS/NZS 1995 5-min or 10-min welding duty cycle vs. AS/NZS 3008.1 continuous 0.6/1 kV switchboard/feeder power).
- Required drum length per size (standard MOQ 300 m; lead time 7 to 45 working days) and optional custom cold-crimped copper lug drawing.
Related selection resources
- Industrial & Custom Welding Cable Supplier Hub
- Industrial Welding Cable 600 V–1 kV Compound Comparison
- Welding Cable Size Chart: Amperage, Length & Duty Cycle
- XLPE Cross-Linked Polyethylene Insulation Engineering Guide
- AS/NZS 1802 Type 241 Flexible Rubber Mining Trailing Cable
AS/NZS 1995 & 5000.1 0.6/1 kV Cable FAQ
Can AS/NZS 1995 & AS/NZS 5000.1 0.6/1 kV cable be used for both arc welding and 415 V / 1 kV switchboard wiring?
Yes. Because it combines full 0.6/1 kV cross-linked primary insulation (X-90 or X-HF-110) with an independent tough outer sheath (TPE-90 or HFS-110-TP), it meets both AS/NZS 1995 welding-lead duty and AS/NZS 5000.1 flexible low-voltage power requirements.
When should I upgrade from 90 °C X-90/TPE-90 to 110 °C X-HF-110/HFS-110-TP LSZH on AS/NZS 1995 cable?
Upgrade to the 110 °C X-HF-110 / HFS-110-TP LSZH build in underground mines, road/rail tunnels, ship hulls, substations and high-density switchboards where zero halogen acid gas, low smoke and +110 °C continuous thermal rating (AS/NZS 4507 RHE design) are required.
Why does the AS 1995 welding table list both 10-minute and 5-minute duty cycles?
10-minute cycle ratings account for heavier thermal accumulation during long submerged-arc or structural runs (e.g., 70 mm² carries 370 A at 60% of 10 min vs. 391 A at 60% of 5 min), preventing insulation overheating on extended passes.
What sizes are available in AS/NZS 1995 & AS/NZS 5000.1 single-core flexible cable?
15 standard metric sizes from 10 mm² up to 630 mm² are manufactured, enabling everything from 16–95 mm² handheld welding leads to 185–630 mm² parallel generator, transformer and mine substation bus drops.
What is the MOQ and lead time for AS/NZS 1995 0.6/1 kV cable, and can lugs be supplied?
300 m per size and color is our standard bulk drum MOQ with a 7 to 45 working days lead time, and we can supply matched flared-entry cold-crimped copper lugs to your terminal bolt drawing.
AS/NZS 1995 & 5000.1 Technical Specifications
AS/NZS 1995 Key Engineering Highlights
- Dual AS/NZS 1995 & AS/NZS 5000.1 0.6/1 kV rating: True two-layer insulation-plus-sheath construction qualifies one single-core flexible cable for both arc-welding leads and 0.6/1 kV power distribution
- 90 °C X-90/TPE-90 & 110 °C LSZH (AS/NZS 4507 RHE): Choose standard 90 °C XLPE/TPE-90 for workshops and yards, or 110 °C X-HF-110/HFS-110-TP LSZH for underground mines, tunnels, ships and switchrooms
- Fine-wire copper across 10 mm² to 630 mm²: 0.21 mm strands (10–35 mm²), 0.31 mm strands (50–95 mm²) and 0.51 mm strands (120–630 mm²) bend cleanly at 4 × D to 6 × D
- Verified 10-min & 5-min AS 1995 duty-cycle data: Complete ampacity schedules for both 10-minute (100%/60%/30%/25%) and 5-minute duty cycles plus 1-phase and 3-phase mV/(A·m) voltage drop
- 300 m bulk MOQ & matched copper lugs: Manufactured to order in 300 m minimum bulk drums (7 to 45 working days) in orange, black or green/yellow with optional cold-crimped copper lugs
| Parameter | Value |
|---|---|
| Rated voltage | U0/U 0.6/1 kV AC (up to 1,500 V DC ripple-free) per AS/NZS 5000.1 and secondary arc-welding duty per AS/NZS 1995 |
| Operating temperature range | Up to +90 °C continuous conductor temperature on X-90/TPE-90 grade; up to +110 °C continuous on X-HF-110/HFS-110-TP LSZH grade |
| Conductor stranding | Flexible annealed copper per AS/NZS 1125 from 10 mm² to 630 mm² (max wire diameter 0.21 mm, 0.31 mm or 0.51 mm by size) |
| Double-insulated construction | Distinct 0.6/1 kV cross-linked primary insulation (X-90 or X-HF-110) plus rugged outer sheath (TPE-90 or HFS-110-TP LSZH) |
| Minimum bending radius | 6 × overall diameter for dynamic welding service; 4 × OD (up to 25 mm OD) to 6 × OD (over 25 mm OD) in fixed 0.6/1 kV flexible routing |
| Minimum order and lead time | 300 m minimum order quantity per cross-section and sheath color; manufacturing lead time 7 to 45 working days |
AS/NZS 1995 & AS/NZS 5000.1 0.6/1 kV Complete Dimensional Schedule (10–630 mm²)
| Model & Size (mm²) | Max Wire Ø (mm) | 90 °C X-90/TPE OD (mm) | 90 °C Mass (kg/km) | 110 °C LSZH OD (mm) | 110 °C LSZH Mass (kg/km) | Max DC R @20 °C (Ω/km) | Bulk MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| AS/NZS 1995 1×10 | 0.21 | 8.5 | 140 | 8.6 | 160 | 1.91 | 300 m | Request this size |
| AS/NZS 1995 1×16 | 0.21 | 9.8 | 200 | 9.8 | 230 | 1.21 | 300 m | Request this size |
| AS/NZS 1995 1×25 | 0.21 | 11.3 | 280 | 11.3 | 310 | 0.780 | 300 m | Request this size |
| AS/NZS 1995 1×35 | 0.21 | 12.5 | 370 | 12.5 | 400 | 0.554 | 300 m | Request this size |
| AS/NZS 1995 1×50 | 0.31 | 14.3 | 510 | 14.3 | 560 | 0.386 | 300 m | Request this size |
| AS/NZS 1995 1×70 | 0.31 | 16.2 | 710 | 16.2 | 750 | 0.272 | 300 m | Request this size |
| AS/NZS 1995 1×95 | 0.31 | 18.1 | 920 | 18.1 | 980 | 0.206 | 300 m | Request this size |
| AS/NZS 1995 1×120 | 0.51 | 20.6 | 1080 | 20.4 | 1130 | 0.161 | 300 m | Request this size |
| AS/NZS 1995 1×150 | 0.51 | 22.5 | 1440 | 22.5 | 1510 | 0.129 | 300 m | Request this size |
| AS/NZS 1995 1×185 | 0.51 | 24.6 | 1750 | 24.8 | 1820 | 0.106 | 300 m | Request this size |
| AS/NZS 1995 1×240 | 0.51 | 27.7 | 2280 | 27.9 | 2360 | 0.0801 | 300 m | Request this size |
| AS/NZS 1995 1×300 | 0.51 | 31.0 | 2820 | 30.8 | 2950 | 0.0641 | 300 m | Request this size |
| AS/NZS 1995 1×400 | 0.51 | 35.4 | 3690 | 34.7 | 3820 | 0.0486 | 300 m | Request this size |
| AS/NZS 1995 1×500 | 0.51 | 40.0 | 4660 | 40.0 | 4830 | 0.0384 | 300 m | Request this size |
| AS/NZS 1995 1×630 | 0.51 | 44.6 | 6180 | 44.6 | 6350 | 0.0287 | 300 m | Request this size |
AS 1995 10-Minute vs. 5-Minute Duty-Cycle Ampacity & Voltage-Drop Schedule
| Conductor Size (mm²) | 100% Continuous (A) | 10-Min Cycle 60% / 30% / 25% (A) | 5-Min Cycle 60% / 30% / 25% (A) | 1-Phase V-Drop mV/(A·m) | 3-Phase V-Drop mV/(A·m) |
|---|---|---|---|---|---|
| 10 mm² | 90 | 91 / 99 / 102 | 96 / 114 / 121 | 5.06 | 4.38 |
| 16 mm² | 125 | 129 / 145 / 151 | 137 / 169 / 181 | 3.10 | 2.68 |
| 25 mm² | 165 | 175 / 206 / 218 | 188 / 239 / 257 | 1.88 | 1.63 |
| 35 mm² | 205 | 223 / 270 / 288 | 238 / 309 / 334 | 1.39 | 1.20 |
| 50 mm² | 260 | 289 / 361 / 386 | 308 / 407 / 440 | 1.05 | 0.906 |
| 70 mm² | 325 | 370 / 471 / 507 | 391 / 523 / 567 | 0.707 | 0.612 |
| 95 mm² | 390 | 454 / 590 / 637 | 476 / 644 / 700 | 0.566 | 0.490 |
| 120 mm² | 455 | 536 / 705 / 763 | 559 / 762 / 829 | 0.453 | 0.392 |
| 150 mm² | 535 | 636 / 843 / 914 | 661 / 904 / 985 | 0.373 | 0.323 |
| 185 mm² | 600 | 723 / 968 / 1051 | 747 / 1027 / 1120 | 0.326 | 0.282 |
| 240 mm² | 715 | 870 / 1174 / 1276 | 895 / 1236 / 1348 | 0.276 | 0.239 |
Engineered and manufactured to AS/NZS 1995, AS/NZS 5000.1, AS/NZS 1125 and AS/NZS 3808 (with 110 °C LSZH grade designed to AS/NZS 4507 RHE reduced-fire-hazard criteria). Fixed 0.6/1 kV power ampacities should be selected in accordance with AS/NZS 3008.1.
Synthetic EPR/CPE elastomer compound alternative (0.6/1 kV) is also available where continuous mineral-oil immersion exceeds thermoplastic TPE-90 duty.
ASCII part references for BOM and ERP entry: TF-AS1995-90TPE-10, TF-AS1995-90TPE-16, TF-AS1995-90TPE-25, TF-AS1995-90TPE-35, TF-AS1995-90TPE-50, TF-AS1995-90TPE-70, TF-AS1995-90TPE-95, TF-AS1995-90TPE-120, TF-AS1995-90TPE-150, TF-AS1995-90TPE-185, TF-AS1995-90TPE-240, TF-AS1995-110LSZH-35, TF-AS1995-110LSZH-70, TF-AS1995-110LSZH-120, TF-AS1995-110LSZH-240, TF-AS1995-110LSZH-500, TF-AS1995-110LSZH-630.
AS/NZS 1995 & 5000.1 Standards & References
| Standard or specification | Application |
|---|---|
| AS/NZS 1995 | Australian/New Zealand standard for flexible arc-welding cables and 10-minute / 5-minute duty-cycle current rating tables. |
| AS/NZS 5000.1 | Electric cables — polymeric insulated — for working voltages up to and including 0.6/1 (1.2) kV. |
| AS/NZS 1125 & AS/NZS 3808 | Conductors in insulated electric cables and insulating/sheathing material specifications (X-90, X-HF-110, TPE-90, HFS-110-TP). |
| AS/NZS 4507 (RHE Design) | Reduced-fire-hazard cable performance benchmark for flame retardance, low smoke emission and halogen-free gas acidity on the 110 °C LSZH build. |
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Industrial Welding Cable 600 V–1 kV — EPDM, EPR, NTC 6078 TPE, CPE & Fabric-Served TSE
A related cable option for a different application or duty profile.
View productDouble-Insulated PVC/NBR (1,000 V SANS 1507 & 300/500 V) & 750 V Hi-Flex PVC Welding Cable (1.5–400 mm²)
A related cable option for a different application or duty profile.
View productH01N2-D & H01N2-E (NSLFFÖU) 100/100 V Rubber Arc Welding Cable (EN 50525-2-81, 10–240 mm²)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.