Project record · Kenya · Drilling rig · 2 kV DLO and H07RN-F

2 kV DLO 535 MCM and H07RN-F 16G2.5 Rubber Cables for a Drilling Rig, Supplied to a Reseller in Kenya

A cable reseller in Kenya ordered two rubber cables for a drilling rig run by one of its customers. The order was 150 m of 2 kV DLO 535 MCM single-conductor power cable in one length, and 300 m of H07RN-F 16G2.5 mm² multicore cable made to a drawing agreed with the buyer. TEBAOFLEX agreed the jacket print with the buyer before production, finished and labelled both cables 19 days after the order was confirmed, and handed them to the buyer's own freight forwarder in China; the cables reached the reseller in Nairobi in August 2026.

Cut end of the TEBAOFLEX 2 kV DLO 535 MCM single-conductor cable made for a drilling rig in Kenya, on a TEBAOFLEX CABLE cloth
Cut end of the 2 kV DLO 535 MCM cable made for this order, with the year 2026 in the jacket print.

Project at a glance

ApplicationPower and multicore cable for a drilling rig operated by the reseller's customer
CustomerCable reseller in Kenya (name not published)
Cable 1DLO 2 kV (2,000 V), 90 °C, tinned copper / EPR / CPE, single conductor 535 MCM (535.3 kcmil, about 271 mm²): 150 m in one length
Cable 2H07RN-F 450/750 V, 16G2.5 mm² (16 cores including one green-yellow core), EN 50525-2-21: 300 m in one length, made to a drawing agreed with the buyer
PrintTEBAOFLEX name, voltage, type and size on both jackets, agreed with the buyer before production
PackingOne wooden drum per cable, each with a TEBAOFLEX drum label and a separate consignee label
DeliveryOrder confirmed 13 May 2026; both cables finished by 1 June; trucked to the buyer's forwarder in China on 3 June; received in Nairobi on 4 August
Scope note. This case covers the two cables: what the reseller asked for, how they are built, what the prints say and how the order travelled. TEBAOFLEX does not make the drilling rig, and the reseller did not tell us which circuits on the rig each cable serves. The reseller, its customer and the commercial terms are not published. When the reseller last reported, in August 2026, the cables had not yet been put into service, because the user still had older cable to use up first.

What is 2 kV DLO 535 MCM cable?

DLO, short for diesel locomotive cable, is a 2,000 V single-conductor flexible power cable with a fine-stranded conductor, a rubber insulation and a rubber jacket. The size in this order, 535 MCM, is a conductor of 535.3 thousand circular mils, about 271 mm² of copper; MCM and kcmil are two spellings of the same unit. It is one of the intermediate DLO sizes, between the 500 and 600 kcmil rows of the North American code tables.

Cut end of the 2 kV DLO 535 MCM cable: a fine-stranded tinned copper conductor inside black EPR insulation and a black CPE jacket
The cut end of the DLO cable: a single bundle of fine tinned-copper strands under the black EPR insulation and the black CPE jacket.
Jacket print on the DLO cable: TEBAOFLEX CABLE 2000V DLO Cable 90°C TCU/EPR/CPE 535MCM 2026
The jacket print, repeated along the cable: TEBAOFLEX CABLE 2000V DLO Cable 90℃ TCU/EPR/CPE 535MCM 2026.
ItemDLO 535 MCM, this order
Voltage rating2,000 V
ConductorRope-lay tinned annealed copper, 1,332 strands of 24 AWG (1332/24), 22.3 mm over the conductor
InsulationEPR, 2.3 mm
JacketBlack crosslinked CPE, 1.7 mm
Overall diameter30.5 mm
Approximate weight2,865 kg/km
Temperature rating90 °C wet or dry
Length supplied150 m in one length on one drum

The dimensions are the 535.3 kcmil row of the size table on our 2 kV DLO cable page, which lists the range from 14 AWG to 1111.1 kcmil. The 150 m was made as one length on one drum, so the runs cut from it on site have no joint in them. A conductor of this size is terminated with lugs made for fine-stranded DLO conductors and crimped with matching tooling; a 444.4 kcmil order with cast copper lugs is documented in our locomotive DLO cable and 1100/24 lug project record.

How much current can 535 MCM DLO carry?

In our DLO ampacity chart, at 30 °C ambient, the 535.3 kcmil size carries 645 A as a single conductor in free air on the 75 °C column and 731 A on the 90 °C column. Run with up to two other current-carrying conductors in a raceway, a cable or the earth, it carries 394 A and 446 A. Which column applies depends on how the cable is installed and on the temperature rating of the terminals it connects to.

Installation basisAt 30 °C ambientAt 40 °C ambient (calculated)
Free air, 75 °C column645 A568 A (× 0.88)
Free air, 90 °C column731 A665 A (× 0.91)
Raceway, cable or earth, 75 °C column394 A347 A (× 0.88)
Raceway, cable or earth, 90 °C column446 A406 A (× 0.91)

The 30 °C values and the 40 °C correction factors come from our ampacity chart for the DLO range, which follows the basis of NEC Tables 310.17 and 310.16; the 40 °C column is a calculation from them, not a test on this order. A machine room or a sunlit route can sit well above 30 °C, so the hotter column is the one to check. Equipment terminals are usually rated 75 °C, which makes the 75 °C column the working limit even though the DLO insulation is rated 90 °C. Where an inspector wants a value read straight from a code table, 535.3 kcmil is commonly treated as the next smaller standard size, 500 kcmil.

DLO is used for flexible power leads on drills, excavators, shovels and other electrically driven equipment, and our guide to what DLO cable is sets out where it fits and where it does not. It should not be chosen by default for a route where the cable is wound on and off a drum in service; that duty may need a construction designed for reeling.

What is H07RN-F 16G2.5, and why sixteen cores?

H07RN-F is the harmonised European heavy-duty rubber flexible cable of EN 50525-2-21, rated 450/750 V, with rubber-insulated cores under a rubber sheath. 16G2.5 means sixteen cores of 2.5 mm² each, one of them the green-yellow protective conductor. With sixteen cores in one sheath, the cable carries many small circuits along one route, rather than one large power circuit as the DLO does.

Cut end of the H07RN-F 16G2.5 mm² cable: fifteen black rubber-insulated cores and one green-yellow core, laid up in two layers under a black rubber sheath
The cut end of the H07RN-F 16G2.5 cable: fifteen black rubber-insulated cores and one green-yellow core, laid up in two layers inside the black rubber sheath.
Sheath print on the H07RN-F cable: TEBAOFLEX CABLE 450/750V H07RN-F 16X2.5mm²
The sheath print: TEBAOFLEX CABLE 450/750V H07RN-F 16X2.5mm², followed on the cable by EN 50525-2-21 Standard and the year.

Before the order, we sent the reseller a specification and drawing for this cable, and it was made to that drawing. A 16-core build has more cores than any size in the reference table on our H07RN-F rubber cable page, which stops at 12 × 2.5 mm², so its construction was agreed on the drawing rather than taken from a catalogue row. The H07RN-F reference data gives a cable surface temperature range of −25 °C to +60 °C in flexing service and a minimum bending radius in mobile use of 6 × the outside diameter for cables over 20 mm. How to read H07RN-F sizes such as 3G2.5 or 16G2.5, and what a datasheet for one should confirm, is covered in our guide to H07RN-F cable sizes and selection.

Agreeing the print before production

Both prints were sent to the reseller as text on 13 May 2026, the day the order was confirmed, and the reseller accepted them the same day, before the cables were made. Each print carries the TEBAOFLEX name, the voltage, the cable type, the size and the year, with a running metre count, so the buyer can check every metre of cable against the order.

TEBAOFLEX CABLE 2000V DLO Cable 90℃ TCU/EPR/CPE 535MCM 2026 000M

TEBAOFLEX CABLE 450/750V H07RN-F 16X2.5mm² EN 50525-2-21 Standard 2026 000M

Printed itemMeaning
2000V DLO Cable 90℃DLO construction rated 2,000 V, conductor temperature up to 90 °C
TCU/EPR/CPETinned copper conductor, EPR insulation, CPE jacket
535MCMConductor size 535 MCM (535.3 kcmil)
450/750V H07RN-FHarmonised heavy-duty rubber flexible cable rated 450/750 V
16X2.5mm²Sixteen cores of 2.5 mm², printed with an x; the cable has one green-yellow core, so its full designation is 16G2.5
EN 50525-2-21 StandardThe European standard for H07RN-F and other cables with crosslinked elastomer insulation
2026 000MYear of manufacture and the running metre count

How the reseller could check the cables were rubber

Before it ordered, the reseller wanted to know that it would receive true rubber cables and full-size copper, not a thermoplastic look-alike or an undersized conductor. Our sales engineer sent factory and production videos, and pointed to what the buyer could check on arrival: the conductor size, the overall diameter and the weight.

The weight check is simple arithmetic. The datasheet weight of the DLO 535 MCM is 2,865 kg/km, so the 150 m length should weigh about 430 kg; the drum label gives 501 kg gross, cable and 1.2 m drum together. On a cut sample, one metre of the cable should weigh about 2.87 kg, and a caliper should read about 30.5 mm over the jacket. The insulation and jacket of the DLO, and the insulation and sheath of the H07RN-F, are crosslinked rubber compounds: they do not melt or flow when heated, and the hot set test is the laboratory check for that crosslinking. The full list of checks, from the print to that test, is in our article on rubber vs TPE cable.

TEBAOFLEX drum label for the DLO order: DLO Cable 2000V 1C 535MCM, packing length 150 m, gross weight 501 kg, drum size 1.2 × 0.7 × 1.2 m, pack 1/1, next to a red tag reading 1x271.1 150 m
Our drum label for the DLO: DLO Cable 2000V 1C 535MCM, 150 m, 501 kg gross, drum 1.2 × 0.7 × 1.2 m, pack 1 of 1, with the red tag for the conductor size, 1×271.1, and the length.

From the factory to Nairobi

The reseller arranged its own freight forwarder in China, which combined the two drums with other goods for the sea voyage to Mombasa. We sent the drums by truck to the forwarder on 3 June 2026, two days after the cables were finished, and they were in its warehouse by 6 June. The consignment then waited for customs clearance at Mombasa, and the reseller received it in Nairobi on 4 August.

The 150 m length of DLO 535 MCM cable wound on a wooden drum on the take-up stand in the factory
The 150 m of DLO 535 MCM on its wooden drum on the take-up stand, with the inner end brought out through the flange.
Close view of the DLO cable turns on the drum before the drum is closed
The DLO turns on the drum before it is closed for shipment.
Date (2026)Step
27 MarchFirst enquiry from Nairobi for DLO cable
13 MayOrder confirmed; jacket prints agreed; production started
29 May to 1 JuneBoth cables finished, photographed and wound on their drums; drum labels fixed
3 JuneDrums trucked to the buyer's forwarder in China (in its warehouse by 6 June)
Late JulyConsignment awaiting clearance at Mombasa
4 AugustCables received by the reseller in Nairobi

In July the reseller told us that the consignment was held at Mombasa because charges on consolidated cargo had been raised. Consolidating a small order with other cargo saves freight, but the drums then depend on how the whole consolidated shipment is handled at the port of arrival, as this order showed. Each drum carried a TEBAOFLEX label and a separate consignee label for the forwarder. When the drums arrived, the reseller reported that they were well packed, and after inspection that the cables were of good quality.

What to send for a DLO or H07RN-F quote

Send these with your enquiry, and we can check the construction and the size against your equipment before quoting.
  • Cable type and voltage, for example DLO 2 kV or H07RN-F 450/750 V
  • Size: kcmil, MCM or AWG for DLO; number of cores × mm² for H07RN-F, with G when a green-yellow core is needed
  • Length of each piece, and whether a length must be delivered without a joint
  • The equipment and the route: free air, tray, raceway, or any part wound on a reel
  • Highest ambient temperature and the terminal temperature rating, for the current check
  • Required jacket print, and any drawing for a non-catalogue construction
  • Delivery port or your forwarder in China, and the drum labelling required

The DLO sizes from 14 AWG to 1111.1 kcmil are on our DLO cable product page, the H07RN-F construction and reference sizes are on the H07RN-F 450/750 V cable page, and the rest of the range is in our industrial cable catalogue. The written quotation confirms the construction, the lengths and the delivery time for your order.

Send your cable sizes and lengths for a quote →

Questions on DLO 535 MCM and H07RN-F 16G2.5 cable

What is 535 MCM DLO cable?

It is a 2 kV single-conductor DLO (diesel locomotive) cable with a 535.3 kcmil conductor, about 271 mm² of copper. In the TEBAOFLEX construction the conductor is rope-lay tinned annealed copper of 1,332 strands of 24 AWG wire, insulated with EPR and jacketed with black crosslinked CPE, rated 90 °C wet or dry. The overall diameter is 30.5 mm and the approximate weight 2,865 kg/km. MCM and kcmil both mean thousands of circular mils, so 535 MCM on a jacket print and 535.3 kcmil on a datasheet describe the same size.

How much current can 535 MCM DLO cable carry?

In the TEBAOFLEX DLO ampacity chart at 30 °C ambient, the 535.3 kcmil size carries 645 A as a single conductor in free air on the 75 °C column and 731 A on the 90 °C column, and 394 A or 446 A on the raceway, cable or earth basis. At 40 °C ambient the correction factors 0.88 and 0.91 bring these to about 568, 665, 347 and 406 A. Equipment terminals usually limit the load to the 75 °C column, and where a code table value is required, 535.3 kcmil is commonly read as the next lower standard size, 500 kcmil.

Is DLO cable suitable for a drilling rig?

DLO is used for flexible power leads on drills, excavators, shovels and other electrically driven equipment, where a large single conductor has to be routed through tight spaces. It is not automatically the right cable for a route where the cable is wound on and off a reel all the time; that duty calls for a purpose-designed reeling cable. Confirm the voltage, the current, the route and any marking the rig's electrical specification requires before ordering.

What does 16G2.5 mean on an H07RN-F cable?

It means 16 cores of 2.5 mm² each, one of which is the green-yellow protective conductor; the G stands for that green-yellow core, and an X would mean a cable without one. H07RN-F is the harmonised 450/750 V heavy-duty rubber flexible cable of EN 50525-2-21, with rubber insulation and a rubber sheath. In H07RN-F cables with more than five cores, the cores other than the green-yellow one are black and identified by printed numbers.

How can I check a rubber cable when it arrives?

Start with the print: the designation, the voltage and the size must match the order, as they did on the two cables in this case. Then measure the overall diameter with a caliper and weigh a cut sample against the datasheet: one metre of the 535 MCM DLO cable should weigh about 2.87 kg. Our article on how to tell vulcanised rubber from thermoplastic elastomer lists the further checks, up to the hot set test, that separate a crosslinked rubber cable from a look-alike.