2XSLCHSWAHK-J 3plus 1.8/3 kV Steel-Wire-Armoured Halogen-Free Symmetrical EMC VFD Motor Cable
2XSLCHSWAHK-J 3plus (2XSLCHSWAHK-J 1.8/3 kV) is a galvanized-steel-wire-armoured, halogen-free low-smoke (LSZH) symmetrical 3+3PE VFD motor supply cable for 690 V to 3.0 kV PWM frequency converters, combining Class 5 bare copper, low-capacitance 90 °C XLPE insulation, 100 % Al-foil plus tinned-copper braid EMC screening, SWA with anti-torsion tape and a UV-resistant black direct-burial jacket.
2XSLCHSWAHK-J 3plus (1.8/3 kV steel-wire-armoured halogen-free VFD cable) connects high-power 690 V, 1,140 V and 2.3–3.0 kV industrial frequency converters to outdoor, underground-duct and direct-buried AC motors across 3×120+3G16, 3×185+3G35 and 3×240+3G50 mm² (346 to 538 A in 30 °C air), tested at 6,500 V AC.
Standard 0.6/1 kV unarmoured 2XSLCYK-J inverter cables face two limits on heavy process plants, mine surface ventilation fans and LNG/chemical tank farms: active-front-end (AFE) 690–1,140 V drives with long motor runs generate reflected-wave voltage peaks exceeding 0.6/1 kV insulation margins, and unarmoured jackets cannot be direct-buried or exposed to rodent/impact hazards without conduit. 2XSLCHSWAHK-J 3plus steps dielectric strength up to 1.8/3 kV low-capacitance XLPE, encloses the symmetrical 3+3PE core in a 100 % dual Al-polyester foil + tinned-copper braid EMC shield, and armours the halogen-free inner bedding with galvanized steel wires under a black UV-resistant LSZH sheath.
Terminate both the tinned-copper EMC braid and the galvanized steel wire armour through 360-degree metallic EMC/SWA glands for full electromagnetic compatibility. For offshore mud-resistant 1.8/3 kV drives see BFOU VFD 1.8/3 kV, and for 3.6/6–6/10 kV drives see TF-MVVFD-3G or 3GSEGCH.
Explore the heavy-duty industrial cable range for related configurations.
2XSLCHSWAHK-J 3plus 1.8/3 kV Armoured EMC Construction
2XSLCHSWAHK-J 3plus pairs VDE-style low-capacitance symmetrical VFD screening with heavy mechanical SWA and EN 60754 / EN 61034 LSZH fire performance.

| Component | Material and construction |
|---|---|
| 1. Conductors | Multi-stranded bare annealed copper, class 5 to EN / IEC 60228 (120 to 240 mm² standard schedule; 35 to 150 mm² on request). |
| 2. Core insulation & 3+3PE layout | 90 °C cross-linked polyethylene (XLPE): three main phase cores (black, brown, grey) laid symmetrically with three split green-yellow protective-earth cores in the interstices. |
| 3. Dual 100 % EMC screen | Electrostatic aluminium-backed polyester tape plus a concentric tinned-copper wire braid providing 100 % total optical/electromagnetic coverage. |
| 4. Inner sheath | Extruded halogen-free flame-retardant bedding compound. |
| 5. Galvanized steel wire armour | Single layer of round galvanized steel wires (SWA) stabilized by a helically applied anti-torsion tape. |
| 6. Outer sheath | Black UV-resistant, self-extinguishing halogen-free low-smoke compound (LOI above 29; EN 60332-1-2, EN 60754, EN 61034) suitable for outdoor racks and direct burial. |
2XSLCHSWAHK-J 3plus Code Breakdown
- 2X: Cross-linked polyethylene (XLPE) 90 °C low-capacitance core insulation
- SL: Low-capacitance symmetrical motor-supply VFD design
- C: Dual 100 % concentric EMC screen (aluminium-polyester tape + tinned-copper wire braid)
- H + SWA + H: Halogen-free inner sheath, round galvanized steel wire armour (SWA) and black UV LSZH outer sheath
- K-J 3plus: Flexible Class 5 copper conductors with three split green-yellow earths (3+3PE)
2XSLCHSWAHK-J 3plus Outdoor, Buried and Heavy VFD Applications
2XSLCHSWAHK-J 3plus serves high-current variable-speed drives exposed to mechanical impact, outdoor UV or buried cable trenches.

- Mine surface main ventilation fans, overland conveyor drive stations, SAG/ball mill pinions and slurry booster pumps on 690 V to 3 kV VFDs.
- Direct-buried, cable-trench and outdoor pipe-rack motor feeders in cement plants, steelworks, water treatment stations and tank farms.
- Tunnels, powerhouses and enclosed process buildings requiring EN 60754 halogen-free and EN 61034 low-smoke evacuation safety.
2XSLCHSWAHK-J 3plus vs 2XSLCYK-J, BFOU VFD and TF-MVVFD-3G
| VFD cable type | Rated U0/U | Armour & jacket | Best-fit installation |
|---|---|---|---|
| 2XSLCHSWAHK-J 3plus (this page) | 1.8/3 kV | Galvanized SWA + black UV LSZH | Direct-buried & outdoor 690 V–3 kV industrial/mine VFD feeders |
| 2XSLCYK-J 3plus | 0.6/1 kV | Unarmoured PVC (or 2XSLCH-J LSZH) | Indoor tray 400–500 V inverter leads without burial/crush risk |
| BFOU VFD 1.8/3 kV | 1.8/3 kV | Tinned Cu braid + NEK 606 mud SHF2 | Offshore topside drilling rigs and FPSO modules |
| TF-MVVFD-3G | 3.6/6 & 6/10 kV | Unarmoured flexible EPR / FR rubber | 3.3–10 kV medium-voltage drive skids and test beds |
Engineering tip: specifying 1.8/3 kV XLPE on long 690 V AFE/IGBT motor feeders provides a > 2.5× phase-to-ground dielectric margin against PWM reflected-wave overshoot.
2XSLCHSWAHK-J 3plus 1.8/3 kV VFD Cable RFQ Checklist
- Cross-section (3x120+3G16, 3x185+3G35, 3x240+3G50 mm², or custom 35–150 mm²) and motor full-load current.
- Converter supply voltage (690 V, 1,140 V, 2.4 kV or 3.0 kV), switching frequency and feeder length (check 70–250 nF/km capacitance).
- Installation route: direct burial in ground, outdoor UV cable ladder, or indoor tunnel tray.
- 360-degree dual-seal SWA + EMC brass cable gland thread and armour clamping range (OD ±5 %).
- Total meterage, drum length limits and delivery target (MOQ 50 m; 7 to 45 working days).
Related selection resources
- Industrial power, VFD motor and armoured cable catalog
- Engineering guide: VFD cable insulation, symmetrical 3-ground geometry and shields
- Engineering guide: XLPE insulation ratings and low-capacitance behaviour
- Engineering guide: foil-plus-braid EMC shielding in motor drive cables
- 2XSLCYK-J 0.6/1 kV unarmoured XLPE VFD motor cable
- BFOU VFD 1.8/3 kV offshore halogen-free mud-resistant drive cable
- 3GSEGCH / 3GSEGCY 3.6/6 & 6/10 kV medium-voltage VFD cable
- TF-MVVFD-3G 3.6/6 & 6/10 kV flexible rubber MV VFD motor cable
2XSLCHSWAHK-J 3plus Armoured LSZH VFD Cable FAQ
Why specify 1.8/3 kV 2XSLCHSWAHK-J 3plus on 690 V or 1,000 V VFD drives?
690–1,140 V IGBT/AFE drives with long cable runs produce steep reflected-wave voltage spikes at the motor terminals that degrade 0.6/1 kV insulation; 1.8/3 kV XLPE tested at 6,500 V provides heavy corona and surge margin.
Can 2XSLCHSWAHK-J 3plus be buried directly in the ground and installed outdoors?
Yes. Its round galvanized steel wire armour protects against soil crush and rodents while the black UV-resistant LSZH outer sheath handles direct sunlight and damp trenches.
How is 100 % EMC screening achieved inside 2XSLCHSWAHK-J 3plus?
2 concentric metallic layers—an aluminium-backed polyester foil tape plus a tinned-copper wire braid—surround the symmetrical 3+3PE cores underneath the inner sheath and SWA armour.
What capacitance values apply to 2XSLCHSWAHK-J 3plus for VFD filter sizing?
70 to 250 nF/km conductor-to-conductor and 110 to 410 nF/km conductor-to-screen, thanks to low-permittivity XLPE insulation.
What are the MOQ and manufacturing lead time for 2XSLCHSWAHK-J 3plus?
50 m minimum order quantity with a production lead time of 7 to 45 working days.
2XSLCHSWAHK-J 3plus 1.8/3 kV Technical Data and Schedule
2XSLCHSWAHK-J 3plus Key Dielectric, Capacitance and Ampacity Data
- 1.8/3 kV PWM dielectric: 90 °C XLPE wall tested at 6,500 V AC withstands steep dV/dt voltage reflections on 690 V, 1,000 V and 2.3–3.0 kV drives
- Symmetrical 3+3PE + 100% EMC: Three phase cores plus three green-yellow earths enclosed by aluminium-polyester tape and tinned-copper wire braid
- Direct-burial SWA armour: Round galvanized steel wire armour (SWA) with helical anti-torsion tape and UV-resistant black LSZH outer sheath (LOI > 29)
- Low XLPE capacitance: 70 to 250 nF/km conductor-to-conductor (110 to 410 nF/km conductor-to-screen) cuts inverter switching losses on long feeders
- High-power sizes: Published 3x120+3G16 to 3x240+3G50 mm² (346 to 538 A) plus custom 35–150 mm² builds; MOQ 50 m in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 1.8/3 kV U0/U; factory AC dielectric test 6,500 V; insulation resistance above 200 MΩ·km |
| Conductor and earth sizes | Class 5 bare copper 3x120+3G16, 3x185+3G35 and 3x240+3G50 mm² (35 to 150 mm² built to order) |
| EMC screen and capacitance | Al-polyester tape plus tinned-Cu braid (100% coverage); C cond/cond 70-250 nF/km, cond/screen 110-410 nF/km |
| Armour and LSZH sheath | Round galvanized steel wire armour with anti-torsion tape and black UV-resistant direct-burial LSZH sheath |
| Operating temperature | -40 °C to +80 °C fixed (-5 °C to +80 °C flexing); 90 °C max conductor (250 °C 1 s short-circuit) |
| Minimum bend radius | 15 x nominal outer diameter (±5 % OD tolerance); 360-degree brass EMC/SWA gland termination |
| Supply terms | MOQ 50 m; manufacturing lead time 7 to 45 working days |
2XSLCHSWAHK-J 3plus 1.8/3 kV Heavy-Drive Schedule
| Model and 3+3PE size | Rated U0/U | Nominal OD (mm) | Min. 15 × OD bend radius (mm) | Current at 30 °C air (A) | Approx. weight (kg/km) | Next step |
|---|---|---|---|---|---|---|
| 2XSLCHSWAHK-J 3plus 3x120+3G16 | 1.8/3 kV | 55.5 | 833 | 346 | 7,650 | Request this size |
| 2XSLCHSWAHK-J 3plus 3x185+3G35 | 1.8/3 kV | 67.8 | 1,017 | 456 | 11,000 | Request this size |
| 2XSLCHSWAHK-J 3plus 3x240+3G50 | 1.8/3 kV | 78.2 | 1,173 | 538 | 15,000 | Request this size |
Current-carrying capacity applies to a single cable in air at 30 °C ambient; apply soil thermal-resistivity and grouping factors for direct-buried trenches.
Smaller and intermediate symmetrical 3+3PE sizes (3x35+3G6, 3x50+3G10, 3x70+3G10, 3x95+3G16 and 3x150+3G25 mm²) are manufactured to project order.
ASCII part references: 2XSLCHSWAHK-J 3x120+3G16 1.8/3 kV; 2XSLCHSWAHK-J 3x185+3G35 1.8/3 kV; 2XSLCHSWAHK-J 3x240+3G50 1.8/3 kV armoured LSZH VFD cable.
2XSLCHSWAHK-J 3plus Standards and Fire Performance
| Standard or specification | Application |
|---|---|
| EN / IEC 60228 | Class 5 multi-stranded flexible bare copper conductors. |
| IEC 60502-1 (1.8/3 kV reference) | 90 °C XLPE insulation thickness, > 200 MΩ·km insulation resistance and 6,500 V AC test voltage. |
| EN / IEC 60332-1-2, 60754 & 61034 | Flame-retardant (LOI > 29), halogen-free acid-gas and low-smoke light-transmittance verification. |
Certifications and document support
TEBAOFLEX ISO quality assurance and routine factory test reports
DIN Media — DIN VDE 0250-813 and DIN VDE 0207-21 standards reference
IEC Webstore — IEC 60228, IEC 60502, IEC 60332 and IEC 60793 standards references
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
2XSLCYK-J 0.6/1 kV XLPE VFD Motor Cable
A related cable option for a different application or duty profile.
View productBFOU VFD 1.8/3 kV Offshore Cable — 3C+3E LSZH
A related cable option for a different application or duty profile.
View productMedium Voltage VFD Motor Cable — 3GSEGCH / 3GSEGCY
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.