35-CHVU 20/35kV Open-Pit Mining Trailing Cable

35-CHVU 20/35 kV trailing cable to DS 074-2004, for feeding large coal extraction machines in open-pit mines.

  • Conductor: fine stranded tinned copper, class 5.
  • Screening: semiconducting layers either side of the rubber insulation.
  • Concentric conductor: 25 mm² copper.
  • Outer sheath: black chloroprene.
  • Range: 3 × 50, 3 × 70, 3 × 95 mm² plus 3 × 16 mm² earth.

Send machine rating, supply distance, route and drum data for RFQ review.

Product information
Brand
TEBAOFLEX
Product overview

35-CHVU 20/35 kV Open-Pit Mining Trailing Cable

35-CHVU is a 20/35 kV trailing cable manufactured to DS 074-2004 for feeding large coal extraction machines in open-pit mines. It sits a full voltage step above the usual mine distribution range: where a 3.6/6 kV to 12/20 kV feeder ends, this is the cable that carries the supply to a dragline, shovel or large excavator at the working face.

The construction is a screened medium-voltage design with a semiconducting layer either side of the rubber insulation, a semiconducting inner sheath, and a 25 mm² concentric copper conductor before the textile tape and the outer chloroprene sheath. That concentric conductor is the earth and screen return path for the whole cable, and its rating has to be checked against the system earth-fault current, not assumed from the phase size.

  • Rated voltage: 20/35 kV; test voltage 53 kV.
  • Cross-sections: 3 × 50, 3 × 70 and 3 × 95 mm², each with 3 × 16 mm² earth and a 25 mm² concentric conductor.
  • Short-circuit temperature: +250 °C; conductor operating temperature +90 °C.
  • Duty: trailing movement, resistant to shock, pressure, abrasion and weather.

For medium-voltage mine distribution below this range see (N)TSCGEWÖU mine distribution cable, and for continuous reel duty see R-(N)TSCGEWÖU reeling cable.

Construction

35-CHVU Cable Construction

Nine-layer screened medium-voltage construction to DS 074-2004. The concentric copper conductor in position 7 is a fixed 25 mm² across all three sizes.

35-CHVU cross-section showing three screened power cores, three earth cores and the 25 mm2 concentric copper conductor
Flat cross-section of the 35-CHVU 20/35 kV trailing cable.
35-CHVU cable construction
No.LayerConstruction
1ConductorFine stranded tinned copper, class 5
2Conductor screenSemiconducting layer
3InsulationRubber insulation, natural colour
4Insulation screenSemiconducting layer
5TapeTextile semiconducting tape
6Inner sheathSemiconducting inner sheath
7Concentric conductorConcentric copper conductor, 25 mm²
8TapeTextile tape
9Outer sheathOuter chloroprene sheath, black

Conductor shape is RF. In the size table the abbreviation konc. denotes the concentric conductor, so 3 × 50 + 3 × 16 + 25 konc. means three 50 mm² phase cores, three 16 mm² earth cores and the 25 mm² concentric conductor.

Applications

35-CHVU Applications

35-CHVU is a trailing flexible cable for feeding large coal extraction machines used in open-pit mines. The cable is sufficiently resistant to shock, pressure, abrasion and weather for surface working conditions.

Open-pit mine bench with a trailing feeder cable running to a large excavator
35-CHVU feeding a large coal extraction machine on an open-pit bench.
  • 20/35 kV supply to draglines, shovels and large excavators at the working face.
  • Trailing routes along benches where the cable is dragged and repositioned as the machine advances.
  • Surface installations exposed to weather, abrasion, pressure and impact.
  • Feeds where supply distance and voltage drop make 20/35 kV the correct system voltage rather than a lower mine distribution level.

Application boundaries

This is a trailing construction rather than a high-speed continuous reeling cable. Where the machine uses a reel, the drum geometry, winding layers, speed and pull govern the selection. The tabulated bending radius is the minimum for the installed route.

Related mining feeder references

Compare (N)TSCGEWÖU mine distribution cable for 3.6/6 kV to 12/20 kV semi-fixed distribution, R-(N)TSCGEWÖU for reel duty and (N)TSCGEWOEU for continuous crane reeling.

Specifications

35-CHVU Specifications

35-CHVU operating data
Rated voltage U₀/U20/35 kV
Manufacturing standardDS 074-2004
Test voltage53 kV
Maximum short-circuit temperature+250 °C
Conductor operating temperature+90 °C
Minimum laying temperature-30 °C
Minimum handling temperature-30 °C
Minimum storage temperature-30 °C
Insulation colourNatural
Sheath colourBlack
Standard packingWooden or metal drums

35-CHVU size and electrical table

Code and cross-sectionOuter diameterWeightBending radiusConductor resistanceShort-circuit current 1 sHeating time constantCurrent capacity in airCapacitanceInductanceCopper content
35-CHVU 3 × 50 + 3 × 16 + 25 konc.92 mm9920 kg/km800 mm0.393 Ω/km6.4 kA331 s215 A0.180 µF/km0.420 mH/km2384 kg/km
35-CHVU 3 × 70 + 3 × 16 + 25 konc.99 mm12022 kg/km800 mm0.277 Ω/km10.0 kA701 s252 A0.207 µF/km0.387 mH/km3072 kg/km
35-CHVU 3 × 95 + 3 × 16 + 25 konc.102 mm13660 kg/km824 mm0.210 Ω/km13.6 kA912 s300 A0.235 µF/km0.362 mH/km3508 kg/km

All three sizes are available to order. Current capacity is the free-in-air value and must be derated for the installed condition. Dimensions and weights are nominal values.

Standards

35-CHVU Standards, Approvals and Order Documentation

Standards applied
ReferenceScopeOrder confirmation
DS 074-2004Manufacturing specification for the 35-CHVU constructionState the designation and cross-section in full.

Approvals

Certification held for this construction
ApprovalStatus
Manufacturing conformity, DS 074-2004Held
20/35 kV routine electrical test package, including 53 kV test voltageHeld
Partial discharge testHeld

Order package

State the machine and its rating, system voltage and earthing arrangement, supply distance and required voltage drop, route profile, whether the cable is trailed or reeled, drum data if applicable, termination type, required drum lengths and any project inspection or documentation scope.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.