36-129 Two-Conductor Blast-Hole Drilling Mast Cable (600/2000 V, 8 AWG–4/0 AWG)
36-129 (series 36-129-008 through 36-129-040) is a two-conductor 600/2000 V blast-hole drilling mast cable engineered with rope-lay tinned copper conductors (8 AWG to 4/0 AWG), 90 °C EPR insulation, integral rubber fillers, open nylon reinforcing braid and an extra-heavy-duty MSHA flame-resistant thermoset chloroprene jacket.
Rotary blast-hole drills, overburden rigs and raise borers subject vertical mast loop cables to simultaneous axial suspension weight, high-amplitude drill-string vibration, rotary head travel flexing and continuous bombardment from drill cuttings, hydraulic oil and sub-zero pit winds. Standard thin-wall Type W cords suffer jacket tearing and core corkscrewing when hung from a 15 m to 30 m drill mast.
The 36-129 two-conductor 600/2000 V drilling mast series (part numbers 36-129-008 through 36-129-040) resolves vertical mast fatigue by pairing rope-stranded annealed tinned copper conductors (133 wires in 8 and 6 AWG; 259 wires in 4, 2 and 1 AWG; up to 532 wires in 4/0 AWG) with 60 mil or 80 mil 90 °C ethylene propylene rubber (EPR) insulation in black and white circuit identification. The two power cores are cabled with full-profile rubber fillers to lock core circularity, wrapped with a reinforcing binder tape and reinforced by an open nylon braid bonded directly into an extra-heavy-duty thermoset chloroprene (CR) outer jacket.
Compared with standard single- or multi-core Type W cables, the 36-129 mast build carries a thicker outer wall—yielding a 0.99 in. (25.1 mm) overall diameter already at 8 AWG and 2.26 in. (57.4 mm) at 4/0 AWG—to absorb mast-guide slap and Chinese-finger grip compression. Specify 36-129 for two-wire DC or single-phase AC rotary drill mast loops, or select Type G-GC / SHD-GC where three-phase power with ground-check monitoring is required.
Explore the mining and tunneling cable range for related configurations.
36-129 Blast-Hole Drilling Mast Cable Construction & Reinforcement
The representative horizontal sample illustrates 36-129-002 (2/C 2 AWG, 1.48 in. nominal O.D.): black and white 90 °C EPR-insulated 259-strand tinned copper conductors cabled with cylindrical rubber fillers, reinforcing binder tape, open nylon braid and an extra-heavy-duty black thermoset chloroprene outer jacket.

| Component | Material and construction |
|---|---|
| Conductors | Flexible rope-lay stranded annealed tinned copper (133 to 532 strands per conductor across 8 AWG to 4/0 AWG) meeting ASTM B33 and ASTM B 172. |
| Insulation & Colour Code | 90 °C ethylene propylene rubber (EPR), 60 mils (8–2 AWG) or 80 mils (1–4/0 AWG), colour-coded black and white. |
| Core Fillers & Binder | Two insulated conductors cabled with elastomeric rubber fillers to maintain a round anti-buckling profile under a reinforcing binder tape. |
| Reinforcing Braid | High-tenacity open nylon braid embedded between the inner bedding/tape and outer elastomer wall to resist vertical stretch and core migration. |
| Outer Jacket | Extra-heavy-duty black thermoset chloroprene (CR) compound resistant to cutting, abrasion, drilling mud, diesel, sunlight and -40 °C cold impact; MSHA flame-resistant. |
36-129 Part Number & Construction Breakdown
- 36-129: two-conductor 600/2000 V extra-heavy-wall blast-hole drilling mast cable series
- -008 to -001: AWG wire gauge suffix from 8 AWG (36-129-008) through 1 AWG (36-129-001)
- -010 to -040: kcmil/aught wire gauge suffix from 1/0 AWG (36-129-010) through 4/0 AWG (36-129-040)
- EPR / Nylon / CR: 90 °C EPR insulation, cabled rubber fillers, open nylon braid and MSHA thermoset chloroprene jacket
36-129 Two-Conductor 600/2000 V Drilling Mast Applications
Deploy 36-129 two-conductor 600/2000 V cables on vertical mast loops, travelling rotary head feeds and high-vibration surface or underground drilling equipment.

- Vertical mast hanging loops and travelling rotary drive head power leads on open-pit rotary blast-hole drilling rigs.
- Two-conductor DC armature/field feeds and single-phase 600/2000 V auxiliary power circuits on overburden drills and raise borers.
- High-vibration mast-mounted motor, blower, hydraulic pump and floodlight circuits exposed to flying rock chips and drilling lubricants.
- Direct part-number replacement for 36-129-008 through 36-129-040 mast cables in surface coal, copper, iron ore and gold mines.
36-129 vs Round Type W and Drill Cord Selection Boundary
| Model | Cores & size range | Wall & reinforcement | Best fit |
|---|---|---|---|
| 36-129 Mast Cable (this page) | 2/C, 8 AWG to 4/0 AWG (600/2000 V) | Rubber fillers + binder tape + open nylon braid + extra-heavy CR jacket | Vertical blast-hole drill mast hanging loops & rotary head leads |
| Round Type W (600/2000 V) | 2/C to 5/C, 8 AWG to 500 kcmil | Standard two-layer thermoset CPE/CR jacket with reinforce braid | General portable trailing power without severe mast slap |
| MSHA Double-Jacket Drill Cord | 2/C to 37/C, 18 AWG to 10 AWG (600 V) | High-visibility dual thermoset rubber jackets | Small-gauge remote control pendants and hand-held drill cords |
| Type G-GC (2000 V) | 3/C + 2 grounds + 1 ground-check | Heavy-duty two-layer thermoset jacket | Three-phase AC mobile mining equipment requiring ground-check |
Verify mast loop suspension grip diameter against the extra-heavy 0.99 in. to 2.26 in. nominal O.D. of the 36-129 series before ordering.
Related selection resources
- Mining and tunneling cable engineering solutions
- Mining cable selection guide: 8 steps for mobile equipment
- Round Type W Portable Power Cable (600/2000 V)
- MSHA Double-Jacket 600V Remote Control and Drill Cord
- Type G-GC Portable Mining Power Cable 2000V
36-129 Blast-Hole Drilling Mast Cable Frequently Asked Questions
Why does a blast-hole drill mast require the 36-129 construction instead of a standard 2-conductor Type W cable?
Vertical mast loops hang under constant self-weight while whipping against mast structural members as the rotary head travels up and down. The 36-129 series uses an extra-heavy-wall thermoset chloroprene jacket (for example 1.48 in. O.D. on 2/C 2 AWG and 2.26 in. O.D. on 2/C 4/0 AWG) over full rubber fillers, binder tape and an open nylon braid to prevent core corkscrewing and jacket splitting in mast cable grips.
How does conductor stranding scale across 36-129-008 through 36-129-040?
To maintain a 6 x O.D. minimum bend radius at the top mast sheave or travelling head clamp, 8 AWG and 6 AWG use 133 tinned copper wires, 4 AWG through 1 AWG use 259 wires, 1/0 AWG uses 266 wires, 2/0 AWG uses 323 wires, 3/0 AWG uses 418 wires and 4/0 AWG uses 532 wires.
When does nominal EPR insulation thickness increase from 60 mils to 80 mils?
Part numbers 36-129-008 through 36-129-002 (8 AWG to 2 AWG) are built with 60 mils (1.52 mm) of 90 °C EPR insulation, while larger sizes 36-129-001 through 36-129-040 (1 AWG to 4/0 AWG) step up to 80 mils (2.03 mm) to withstand higher mechanical compression on large mast sheaves.
What details should be confirmed when requesting a quotation for 36-129 mast cable?
Specify the exact part number (36-129-008 to 36-129-040) or AWG size, cut loop length or reel length, upper and lower mast basket/Kellems grip diameter range, and required test documentation.
36-129 Part Numbers, Dimensions, Ampacity & Technical Specifications
36-129 Key Specifications
- Part range: 36-129-008 (8 AWG) to 36-129-040 (4/0 AWG) two-conductor round mast cable
- Voltage & ampacity: 600/2000 V rating; 54 A to 255 A continuous ampacity at 40 °C ambient
- Conductor stranding: 133-wire (8–6 AWG), 259-wire (4–1 AWG) up to 532-wire (4/0 AWG) tinned copper
- Mast reinforcement: Cabled with rubber fillers, binder tape and open nylon braid under extra-heavy CR jacket
- Service envelope: -40 °C to +90 °C continuous rating; 6 x O.D. minimum bend radius; MSHA flame-resistant
| Parameter | Value |
|---|---|
| Part number series | 36-129-008 to 36-129-040 (2/C 8 AWG to 2/C 4/0 AWG) |
| Voltage & temperature rating | 600/2000 V; -40 °C to +90 °C continuous conductor temperature |
| Diameter & weight range | 0.99 to 2.26 in. (25.1 to 57.4 mm) nominal O.D.; 670 to 4650 lbs/1000 ft (997 to 6920 kg/km) |
| Ampacity & bend radius | 54 A (8 AWG) to 255 A (4/0 AWG) at 40 °C ambient; minimum bending radius 6 x cable O.D. |
| Flame & mechanical compliance | ICEA S-75-381 / NEMA WC 58 heavy-duty thermoset construction; MSHA 30 CFR Part 7 flame resistance |
| Commercial supply terms | Minimum order quantity 50 m; manufacturing lead time 7 to 45 working days; final values confirmed on the quotation drawing |
| Selection boundary vs Round Type W and Drill Cord | Choose 36-129 for 2-conductor 8 AWG to 4/0 AWG extra-heavy-wall 600/2000 V drill mast suspension; choose MSHA 600 V double-jacket drill cord for 16–12 AWG multi-core remote pendants, or Round Type W / Type G-GC for 3- and 4-conductor trailing power. |
36-129 (36-129-008 to 36-129-040) Dimensional & Ampacity Schedule
| Part No. | Conductor Size | Stranding (Wires) | Nom. Insulation Thickness | Nominal O.D. | Approx. Weight | Ampacity (40 °C) | Next step |
|---|---|---|---|---|---|---|---|
| 36-129-008 | 8 AWG | 133 | 60 mils (1.52 mm) | 0.99 in. (25.1 mm) | 670 lbs/1000 ft (997 kg/km) | 54 | Request this size |
| 36-129-006 | 6 AWG | 133 | 60 mils (1.52 mm) | 1.10 in. (27.9 mm) | 890 lbs/1000 ft (1324 kg/km) | 72 | Request this size |
| 36-129-004 | 4 AWG | 259 | 60 mils (1.52 mm) | 1.27 in. (32.3 mm) | 1250 lbs/1000 ft (1860 kg/km) | 93 | Request this size |
| 36-129-002 | 2 AWG | 259 | 60 mils (1.52 mm) | 1.48 in. (37.6 mm) | 1800 lbs/1000 ft (2679 kg/km) | 122 | Request this size |
| 36-129-001 | 1 AWG | 259 | 80 mils (2.03 mm) | 1.68 in. (42.7 mm) | 2270 lbs/1000 ft (3378 kg/km) | 143 | Request this size |
| 36-129-010 | 1/0 AWG | 266 | 80 mils (2.03 mm) | 1.79 in. (45.5 mm) | 2680 lbs/1000 ft (3988 kg/km) | 165 | Request this size |
| 36-129-020 | 2/0 AWG | 323 | 80 mils (2.03 mm) | 1.93 in. (49.0 mm) | 3200 lbs/1000 ft (4762 kg/km) | 192 | Request this size |
| 36-129-030 | 3/0 AWG | 418 | 80 mils (2.03 mm) | 2.07 in. (52.6 mm) | 3627 lbs/1000 ft (5398 kg/km) | 221 | Request this size |
| 36-129-040 | 4/0 AWG | 532 | 80 mils (2.03 mm) | 2.26 in. (57.4 mm) | 4650 lbs/1000 ft (6920 kg/km) | 255 | Request this size |
36-129 Construction & Operating Parameters
| Parameter | Specification |
|---|---|
| Rated Operating Voltage | 600/2000 V AC / DC heavy-duty mast & hanging loop power |
| Conductor & Insulation | Flexible stranded annealed tinned copper (133 to 532 wires) with 90 °C EPR insulation (black & white cores) |
| Core Assembly & Reinforcement | Two insulated conductors cabled with integral rubber fillers, reinforcing binder tape and open nylon braid |
| Outer Jacket Compound | Extra-heavy-duty black thermoset chloroprene (CR) elastomer jacket with integral tensile reinforcement |
| Operating Temperature & Bend Radius | -40 °C to +90 °C continuous conductor temperature; minimum bending radius 6 x cable O.D. |
| Flame & Crush Qualification | Flame-resistant in accordance with MSHA 30 CFR Part 7; built for vertical mast suspension and drill vibration |
Ampacities in the 36-129 schedule are based on a single two-conductor cable in free air at 40 °C ambient and 90 °C maximum conductor temperature per ICEA S-75-381 / NEMA WC 58. Insulation thickness steps from 60 mils (1.52 mm) on 8 AWG through 2 AWG to 80 mils (2.03 mm) on 1 AWG through 4/0 AWG.
MSHA 30 CFR Part 7, UL 1277 TC-ER-HL, ICEA S-75-381 / NEMA WC 58 and CSA C22.2 No. 230 / No. 239 are cited as governing design and test references; TEBAOFLEX manufactures to the referenced construction parameters and confirms project-specific marking and test documentation on the quotation drawing.
ASCII part references for BOM and ERP entry: 36-129-008, 36-129-006, 36-129-004, 36-129-002, 36-129-001, 36-129-010, 36-129-020, 36-129-030, 36-129-040.
36-129 Standards & Test References (ICEA S-75-381, MSHA)
| Standard or specification | Application |
|---|---|
| ICEA S-75-381 / NEMA WC 58 | Portable and power feeder cables for use in mines and similar applications (construction, EPR insulation, thermoset CR jacket and ampacity basis). |
| MSHA 30 CFR Part 7 | Flame-resistance test qualification reference for surface and underground mining cables. |
| ASTM B33 / ASTM B 172 | Specifications for tinned soft or annealed copper wire and rope-lay stranded copper conductors. |
| UL 44 / CSA C22.2 No. 38 | Thermoset-insulated wire and cable reference for 90 °C EPR dielectric performance. |
Certifications and document support
TEBAOFLEX company certificates and quality system documentation
NEMA / ICEA S-75-381 (NEMA WC 58) portable mining cable standard reference
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type W Cable 2000V – Round 4/C, 3/C and Flat Options
A related cable option for a different application or duty profile.
View productSOOW Multi-Core 600V MSHA Mining Control Cable (5 to 60 Cores)
A related cable option for a different application or duty profile.
View productCrush-Resistant TC-ER 600V and 1kV Mining Power and Lighting Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.