4H18, A240 & 6SSA5 4-Conductor Quad & Multi-Core Borehole Geophysical Logging Cable (300–1200 V)
4H18, A240250, 4H31, 3Q37RP and 6SSA5 double-armoured borehole geophysical logging cables combine four star-quad conductors (3/16 in 4.72 mm to 5/16 in 7.94 mm), three power/telemetry cores (4.70 to 12.04 mm) or hybrid RG59 coaxial plus control cores (15.85 mm) inside torque-balanced contra-helical galvanized steel wire armour rated from 14.7 kN to 115 kN breaking strength.
4H18, A240185, A240250, 4H31, 3Q37RP and 6SSA5 double-armoured borehole geophysical logging cables bridge the gap between single-conductor E-line and heavy 15/32 in oilfield heptacables, supplying 300 to 1,200 V DC downhole probe power and balanced multi-channel telemetry in compact outer diameters from 4.70 mm (3/16 in) to 15.85 mm.
In mineral exploration (coal, copper, gold, iron ore, uranium and lithium brine), hydrogeological water-well surveys, geotechnical dam/tunnel coring and shallow marine borehole probes, diamond-drilled HQ/NQ/BQ boreholes and portable 12/24 V or AC winches cannot accommodate 500 kg/km oilfield heptacables. A 3/16 in 4H18RPP or A240185 star-quad cable weighs only 89 kg/km in air with a 250 mm minimum sheave diameter while providing four independent 24 AWG copper conductors (two diagonally opposed differential pairs) protected by two contra-helical preformed GIPS steel wire armour layers (13.8 to 16.9 kN breaking load).
Choose 4H18 / A240185 (4.72 mm) or 4H25 / A240250 (6.35 mm, 25.8 kN) for slim mineral, gamma, caliper, magnetic susceptibility, full-waveform sonic and optical/acoustic televiewer sondes; step up to 3Q37RP (9.58 mm) or 3H47PTZ (12.04 mm, 97.9 kN) for high-current 3-phase downhole heaters, samplers and deep geothermal tools; or select 6SSA5 (15.85 mm, 3xRG59 coax + 6×0.50 mm², 115 kN) for high-bandwidth borehole video and multi-channel seismic arrays.
Explore the oil, gas and petrochemical cable range for related configurations.
4H18, A240 & 6SSA5 Star-Quad & Multi-Core Double-Armoured Construction
TEBAOFLEX small-OD quad, 3-core and multi-coax borehole cables pair precision-laid star-quad or coaxial/control cores with tightly closed preformed contra-helical galvanized plow steel armour so bare armoured lines spool cleanly onto compact geophysical winches without birdcaging.

| Component | Material and construction |
|---|---|
| 1. Stranded Tinned Copper Conductors (24 AWG to 16 AWG) | 7-wire or 19-wire stranded tinned annealed copper conductors (7x0.203 mm on 4H18; up to 16 AWG on 3H47; plus 75 Ω copper-braid coaxial elements on 6SSA5) water-blocked against hydrostatic ingress. |
| 2. Low-Capacitance Polyolefin or High-Temp Fluoropolymer Insulation | Modified copolymer polypropylene (PP, 149 °C / 300 °F) or XLPE for low dielectric loss (118 pF/m on 4H18RPP) in mineral and water boreholes, with ETFE / FEP-ETFE (216 to 260 °C) available for hot geothermal holes. |
| 3. True Star-Quad or Hybrid Coax-Control Core Layup | Four colour-coded cores cabled in true helical star-quad geometry around a central elastomeric filler (diagonal pairs canceling magnetic pickup), or three 75 Ω RG59 coaxes cabled with six 0.50 mm² control cores on 6SSA5. |
| 4. Water-Blocking Bedding & Pressure-Sealing Interlayer | Polyester wrap and inter-armour corrosion-inhibiting water-blocking compound preventing longitudinal fluid wicking under borehole hydrostatic heads up to 35–70 MPa. |
| 5. Double Contra-Helical Preformed GIPS Wire Armour | Inner right-hand and outer left-hand preformed Galvanized Improved / Extra Improved Plow Steel (GIPS/GEIPS) armour wires (12/18, 16/20 or 18/18 stranding) balancing torque and serving as metallic return/shield. |

4H18 / A240 / 3Q / 6SSA5 Borehole Cable Code Breakdown
- 4H18 / 4H25 / 4H31: 4-conductor star-quad double-armoured logging series in 3/16 in (0.186 in / 4.72 mm), 1/4 in (0.250 in / 6.35 mm) and 5/16 in (0.312 in / 7.94 mm)
- A240185 / A240250: oceanographic and borehole 4-conductor double-armoured instrumentation equivalents rated 400 V (14.7 kN) and 600 V (25.8 kN)
- 3STK / 3Q37RP / 3H47PTZ: 3-conductor double-armoured borehole cables spanning 4.70 mm slim ETFE up to 12.04 mm (97.9 kN, 260 °C FEP/ETFE) high-power logging
- 6SSA5: hybrid multi-coaxial double-armoured geophysical cable combining three 75 Ω RG59 coaxes with six 0.50 mm² control conductors (15.85 mm, 115 kN)
4H18 & A240 Mineral Slim-Hole, Hydrogeological & Borehole Televiewer Applications
Specify 4H, A240, 3Q/3H and 6SSA5 borehole cables for mineral exploration winches, hydrogeological logging trucks, geotechnical shaft/tunnel investigation and nearshore marine seabed probes.

- Coal, metalliferous (copper, gold, iron, uranium) and potash slim-hole wireline logging through BQ, NQ and HQ core barrels (natural gamma, density, resistivity, induced polarization and gyro deviation).
- Acoustic televiewer (ATV), optical televiewer (OTV), full-waveform sonic and borehole radar surveys requiring balanced 2-pair star-quad telemetry with low attenuation.
- Hydrogeological aquifer profiling, deep water-well camera inspection, flowmeter/fluid-conductivity logging and geotechnical dam/tunnel grouting verification.
- Multi-channel downhole seismic geophone clamping tools, marine sparker/boomer acoustic arrays and high-power 3-conductor downhole fluid sampling using 3Q37RP, 3H47PTZ and 6SSA5.
4H18 & A240 Quad vs 7-Core Heptacable vs Coaxial Borehole Selection
| Borehole Cable Type | OD & Air Weight | Strength Member | Best-Fit Borehole & Winch Duty |
|---|---|---|---|
| 4H18 / A240185 3/16 in Quad (this page) | 4.72 mm | 89 kg/km | 2-layer GIPS steel wire armour (14.7–16.9 kN) | Portable mineral exploration winches (300–2,000 m) inside BQ/NQ/HQ drill rods |
| 4H25 / A240250 1/4 in Quad (this page) | 6.35 mm | 159 kg/km | 2-layer GIPS steel wire armour (25.8 kN) | Deeper mineral, coal, hydrogeological & acoustic televiewer boreholes (1,000–3,500 m) |
| 6SSA5 3-Coax + 6-Core (this page) | 15.85 mm | 680 kg/km | Heavy 2-layer GIPS steel wire armour (115 kN) | High-bandwidth borehole HD video, multi-coax sonar & clamped borehole seismic arrays |
| 7H42 / 7J46 7-Core Heptacable (10.8–11.8 mm) | 10.82–11.80 mm | 464–512 kg/km | Heavy oilfield 2-layer SWA (78–95 kN) | Full-diameter oil, gas & deep geothermal open-hole quad-combo logging trucks |
For portable mineral exploration winches with 250 to 360 mm drum cores, 3/16 in (4.72 mm) 4H18 or 1/4 in (6.35 mm) A240250 holds 3x to 5x more cable length per drum than a 7/16 in oilfield heptacable.
4H18 & Borehole Geophysical Logging Cable RFQ Ordering Checklist
- Core count and arrangement: 4-conductor star-quad (4H18, A240185, A240250, 4H31), 3-conductor (3STK, 3Q37RP, 3H47) or hybrid coax + control (6SSA5).
- Target nominal outer diameter (4.72 mm / 3/16 in, 6.35 mm / 1/4 in, 7.94 mm / 5/16 in or custom) to match winch level-wind pitch and sonde cablehead.
- Maximum borehole temperature and fluid type (freshwater, saline brine, acidic mine water or hot geothermal fluid up to 232–260 °C).
- Surface finish: standard bare galvanized steel wire armour or optional extruded PUR / HDPE outer jacket.
- Continuous cut length per drum (MOQ 50 m; lead time 7 to 45 working days) and portable winch flange/core dimensions.
Related selection resources
- Oil, gas and geophysical borehole logging cable catalog
- Downhole, borehole and oilfield cable engineering selection guide
- Heptacable 7H42, 7J46 & W7 7-Conductor Double-Armoured Wireline Logging Cable
- Monoconductor Slim-Hole & Cased-Hole Wireline Logging Cable
- CTD Profiling, Sonar & Oceanographic Instrumentation Winch Cable
- Selection guide: 1-Core Monoconductor vs 4-Core Quad vs 7-Core Heptacable Wireline
4H18, A240 & 6SSA5 Borehole Logging Cable Frequently Asked Questions
Why do mineral and hydrogeological logging winches use 3/16 in 4H18 or 1/4 in A240250 4-conductor quad cable instead of 7-conductor heptacable?
89 to 159 kg/km air weight and 4.72 to 6.35 mm outer diameter allow 1,000 to 2,500 m of 4-conductor star-quad cable to spool onto compact truck, ATV or heli-portable mineral winches with 254 to 355 mm sheaves, while still providing two balanced differential pairs for downhole power and digital televiewer telemetry through NQ/BQ core rods.
How should the 4 conductors in a 4H18 or A240250 borehole star-quad cable be paired?
2 diagonally opposed pairs (Conductor 1 paired with Conductor 3, and Conductor 2 paired with Conductor 4, plus the outer steel wire armour as metallic return/shield) preserve symmetric mutual capacitance (118 to 125 pF/m) and cancel electromagnetic interference between probe power and telemetry.
When should 6SSA5 hybrid coaxial borehole cable be selected over a 4-conductor quad cable?
3 independent 75 Ω RG59 coaxial cores plus 6 x 0.50 mm² tinned copper control cores make 6SSA5 (15.85 mm OD, 115 kN breaking strength) the right choice when analog/HD borehole video, multi-frequency acoustic imaging or multi-level borehole seismic tools exceed twisted-quad bandwidth.
Can 4H18 and A240250 borehole logging cables be manufactured with high-temperature ETFE/FEP insulation for geothermal slim holes?
Yes. While standard 4H18RPP uses 149 °C copolymer polypropylene for low capacitance, TEBAOFLEX also extrudes ETFE and composite FEP/ETFE insulation rated to 232–260 °C across 3/16 in (3STK / 4H18-HT), 1/4 in (4H25-HT) and 0.474 in (3H47PTZ) borehole cables.
What are the minimum order quantity and lead time for 4H18, A240250 and 6SSA5 borehole logging cables?
50 m minimum order quantity (MOQ), manufactured in 7 to 45 working days in exact continuous drum lengths (such as 300 m, 500 m, 1,000 m, 1,500 m or 3,000 m).
4H18, A240, 3Q/3H & 6SSA5 Dimensional, Electrical & Tensile Specifications
4H18 & Borehole Quad Key Voltage, Capacitance, Weight & Sheave Summary
- Slim-hole mineral & hydro-logging ODs: 3/16 in (4.72 mm 4H18 / A240185), 1/4 in (6.35 mm 4H25 / A240250) and 5/16 in (7.94 mm 4H31) star-quad builds fit NQ, BQ and HQ diamond-drill rods
- Balanced star-quad differential pairs: Four diagonally opposed tinned copper conductors (24 AWG to 20 AWG) deliver two low-crosstalk differential telemetry/power pairs without heavy 7-core weight
- 3-core & multi-coax borehole extensions: Includes 3STK / 3Q37RP / 3H47PTZ 3-conductor logging cables (up to 1,200 V DC, 260 °C) and 6SSA5 (3x75 Ω RG59 coax + 6x0.50 mm² control, 115 kN)
- Portable winch compatibility: Lightweight 88 to 255 kg/km air mass and 250 to 400 mm minimum sheave diameters suit truck, trailer, backpack and heli-portable mineral logging winches
- Short & custom drum lengths: Minimum order quantity 50 m (including 300 m, 500 m, 1,000 m, 1,500 m and 3,000 m borehole drums) delivered in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 300 V DC to 600 V DC on 3/16 in and 1/4 in star-quads; 1,000 to 1,200 V DC on 4H31 and 3Q/3H; 2.3/3.0 kV on 6SSA5 |
| Core layouts covered | 4-conductor star-quad (4H18, A240185, A240250, 4H31), 3-conductor (3STK, 3Q37RP, 3H47) and 3xRG59 coax + 6x0.50 mm² (6SSA5) |
| Outer diameter envelope | 4.70 to 4.72 mm (3/16 in), 6.35 mm (1/4 in), 7.94 mm (5/16 in), 9.58 mm (3/8 in), 12.04 mm (0.474 in) and 15.85 mm |
| Nominal breaking strength | 13.8 to 16.9 kN (3/16 in quad), 25.8 kN (1/4 in quad), 44.5 kN (5/16 in quad), 58.7 to 97.9 kN (3-core) and 115.0 kN (6SSA5) |
| Minimum sheave diameter and supply | 250 mm (10 in) on 4H18 up to 660 mm on 3H47, with MOQ 50 m and 7 to 45 working days manufacturing lead time |
| Operating temperature range | -40 to +90 °C (6SSA5 coaxial), 149 °C / 300 °F (copolymer PP borehole quads) and up to 232–260 °C (ETFE / FEP-ETFE geothermal builds) |
| Armour electrical return | Preformed double contra-helical GIPS steel wire armour (typical armour DC resistance 12 to 22 Ω/km on 3/16 in to 1/4 in quads) |
4H18, A240, 3Q/3H & 6SSA5 Borehole Logging Cable Dimensional & Electrical Schedule
| Model & Core Configuration | Nominal OD (mm | in) | Conductor Size & Insulation | Rated Voltage & Temp. | DC Resistance | Cap. (Ω/km | pF/m) | Weight Air | Water (kg/km) | Min. Sheave | Breaking Load (mm | kN) | Next step |
|---|---|---|---|---|---|---|---|
| 4H18RPP Star-Quad Borehole (4x24 AWG) | 4.72 | 0.186 | 4x24 AWG Sn-Cu | Copolymer PP | 300–600 V | 149 °C | 73.8 | 118 | 89 | 74 | 254 | 13.8–16.9 | Request this size |
| A240185 4-Core Borehole Quad (4x24 AWG) | 4.72 | 0.186 | 4x24 AWG Sn-Cu | Polyolefin/FEP | 400 V | 149–200 °C | 78.0 | 120 | 89 | 73 | 254 | 14.7 | Request this size |
| 4H25 / A240250 Borehole Quad (4x22 AWG) | 6.35 | 0.250 | 4x22 AWG Sn-Cu | PP or ETFE | 600 V | 149–232 °C | 50.5 | 125 | 159 | 130 | 355 | 25.8 | Request this size |
| 4H31 Borehole Quad (4x20 AWG) | 7.94 | 0.312 | 4x20 AWG Sn-Cu | PP or FEP/ETFE | 1000 V | 149–232 °C | 33.5 | 135 | 255 | 210 | 430 | 44.5 | Request this size |
| 3STK Slim 3-Core Borehole (3x24 AWG) | 4.70 | 0.185 | 3x24 AWG Sn-Cu | ETFE Fluoropolymer | 600 V | 232 °C | 76.0 | 115 | 88 | 72 | 254 | 15.6 | Request this size |
| 3Q37RP 3-Core Borehole Logging (3x19 AWG) | 9.58 | 0.377 | 3x19 AWG Sn-Cu | Copolymer PP | 1200 V | 149 °C | 23.3 | 154 | 347 | 286 | 483 | 58.7 | Request this size |
| 3H47PP / 3H47PTZ Borehole 3-Core (3x16 AWG) | 12.04 | 0.474 | 3x16 AWG Cu | PP (149 °C) or FEP/ETFE | 1200 V | 149–260 °C | 19.7 | 144 | 549–568 | 451–470 | 660 | 97.9 | Request this size |
| 6SSA5 Hybrid Borehole (3xRG59 Coax + 6x0.5 mm²) | 15.85 | 0.624 | 3x75 Ω Coax + 6x20 AWG | XLPE | 2.3/3.0 kV | 90 °C | 39.0 (ctrl) | 67 (coax) | 680 | 520 | 650 | 115.0 | Request this size |
In 4-conductor star-quad borehole cables (4H18, A240185, A240250 and 4H31), pair diagonally opposite conductors (Core 1 with Core 3, Core 2 with Core 4) to maximize common-mode noise rejection between downhole DC power and acoustic/televiewer data.
Optional extruded polyurethane (PUR) or HDPE outer jackets over the double steel wire armour can be specified where borehole logging cables double as shallow marine tow, shaft camera or acidic mine-water monitoring lines.
Minimum order quantity is 50 m with a production lead time of 7 to 45 working days, supporting exact cut lengths (300 m, 600 m, 1,000 m, 1,500 m, 2,500 m) for portable mineral exploration winches.
ASCII part references: 4H18; 4H18RPP; 4H25; 4H31; A240185; A240250; A301592; 3STK; 3Q37RP; 3Q40PXZ; 3H47PP; 3H47PXZ; 3H47PTZ; 6SSA5; 1SSA4; 1SSA6; 1SSA13.
4H18 & Borehole Geophysical Cable Conductor & Mechanical Test Standards
| Standard or specification | Application |
|---|---|
| ASTM B33 & IEC 60228 Stranded Conductors | Tinned copper 7-wire and 19-wire conductors resisting oxidation in wet mineral boreholes, saline aquifers and marine geotechnical coring. |
| Star-Quad Balanced Telemetry Geometry | Symmetric 4-core quad layup maintaining balanced pair capacitance (118 to 135 pF/m) and low inter-pair crosstalk for digital borehole sondes. |
| Preformed GIPS Contra-Helical Wire Armour | Two opposing layers of high-tensile galvanized plow steel wire tested for fixed-end breaking load, torque balance and multi-layer drum crush resistance. |
Certifications and document support
TEBAOFLEX ISO 9001 factory quality, conductor resistance, capacitance and tensile test records
ASTM B33 — Standard specification for tinned soft or annealed copper wire for electrical purposes
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Heptacable 7H42, 7J46 & W7 7-Conductor Double-Armoured Wireline Logging Cable (1–1.5 kV DC)
A related cable option for a different application or duty profile.
View product4SSA27 & FIMT-EO Armoured Fiber-Optic & Hybrid Electro-Optical Wireline Logging Cable (DTS / DAS)
A related cable option for a different application or duty profile.
View productMonoconductor Wireline Logging Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.