Oil and Gas Cables TEBAOFLEX

Heptacable 7H42, 7J46 & W7 7-Conductor Double-Armoured Wireline Logging Cable (1–1.5 kV DC)

Heptacable 7-conductor wireline logging cables (7H32, 7H37, 7H42, 7J46, 7H47 Slammer and W7 series, 1,000 to 1,500 V DC) combine a 6+1 concentric core of stranded copper conductors insulated with modified copolymer polypropylene (150 °C) or FEP/ETFE/PFA fluoropolymers (205 to 260 °C) inside double contra-helical GIPS or sour-service alloy wire armour (6.40 to 13.20 mm OD, 25 to 151 kN breaking strength).

Product information
SKU
TF-7H-HEPTA-LOGGING
Brand
TEBAOFLEX
Product overview

Heptacable 7-conductor double-armoured wireline logging cables (7H32, 7H37, 7H42, 7J46, 7H47 and W7 series) are the primary open-hole formation-evaluation and offshore deep-well logging workhorses, delivering multi-channel 1,000 to 1,500 V DC downhole tool power and simultaneous high-speed telemetry across outer diameters from 6.40 mm (1/4 in) to 13.20 mm (0.520 in) and breaking loads from 25 kN to 151 kN.

Inside every heptacable, six outer insulated stranded tinned or nickel-coated copper conductors (22 AWG to 17 AWG) are laid concentrically around one central seventh conductor over water-blocked void fillers so differential telemetry pairs, orthogonal tool-power buses and armour return paths operate with <= 30 mV shield equilibrium and 130 to 160 pF/m capacitance at 1 kHz. Preformed contra-helical inner and outer steel armour layers with inter-armour pressure-sealing compound control rotational torque and cable stretch (0.61 to 2.80 m/km/5 kN) during high-tension spudding, rotary sidewall coring and differential-sticking pull-free operations.

Select 7H42 (7/16 in, 10.82 mm, 78.3 kN) or 7J46 / W7BPP-11.8 (15/32 in, 11.80 mm, 85 to 91.2 kN) for standard land and offshore open-hole logging suites, upgrade to 0.474 in 7H47 / W7BPP-HS24-12.04 Slammer (109 kN) or 0.520 in W7PP-HS34-13.2 (151 kN) for high-deviation sticky wellbores, or step down to 1/4 in W7F46-6.4 (6.40 mm) for slim-hole and through-tubing multi-sensor runs. For single-core cased-hole perforating see our Monoconductor Wireline Logging Cable, or for optical DTS/DAS sensing see our 4SSA27 & FIMT-EO Electro-Optical Wireline Cable.

Explore the oil, gas and petrochemical cable range for related configurations.

Construction

Heptacable 7H, 7J & W7 6+1 Core & Preformed Double-Armour Construction

Each TEBAOFLEX 7-conductor heptacable is manufactured with water-blocked 7-wire copper strands, concentric pinhole-free extruded thermoplastic or fluoropolymer insulation, elastomeric bedding filler and stress-relieved preformed contra-helical wire armour engineered to hold roundness under multi-layer winch spooling and grease-head pack-off pressure.

Clean 2D engineering cross-section of 7-conductor heptacable wireline logging cable showing one central insulated stranded copper conductor surrounded by six concentric insulated copper cores, void-filling bedding and two contra-helical preformed steel wire armour rings
Heptacable 6+1 cross-section: 1 central + 6 outer 7-wire copper conductors, PP or FEP/ETFE insulation, polymeric filler and inner/outer contra-helical steel armour.
Heptacable 7H42, 7J46 & W7 7-Conductor Double-Armoured Wireline Logging Cable (1–1.5 kV DC) construction
ComponentMaterial and construction
1. Water-Blocked Stranded Conductors (6 + 1 Concentric Core)Seven 7-wire stranded tinned copper conductors per ASTM B 33 (up to 205 °C) or ASTM B 355 Class 10 nickel-coated copper (up to 260 °C), 7x0.21 mm to 7x0.33 mm / 22 to 17 AWG, with internal strand voids sealed against downhole gas and fluid migration.
2. Temperature-Graded Core Insulation (150 °C / 232 °C / 260 °C)Modified copolymer polypropylene (PP, 150 °C / 300 °F) for standard gradients, dual-extruded FEP + copolymer PP or FEP + ETFE (232 °C / 450 °F) for deep HPHT wells, or pure FEP/ETFE and PFA fluoropolymer walls (260 °C / 500 °F) for extreme geothermal and ultra-deep boreholes.
3. 6+1 Symmetrical Cabling & Void-Free MatrixSix colour-coded/numbered outer insulated cores helically laid around one central core with high-temperature polymeric valley fillers and binder tape to preserve low crosstalk and uniform radial compression support.
4. Inner Preformed Steel or Alloy Wire Armour + Pressure Sealant16 to 24 right-hand preformed high-tensile galvanized plow steel (GIPS/GEIPS) or sour-service corrosion-resistant alloy wires embedded in high-temperature anti-corrosion and pressure-sealing compound to block annular gas migration.
5. Outer Contra-Helical Preformed Wire Armour (Torque-Balanced)18 to 26 left-hand heavy-diameter preformed GIPS/GEIPS, S75/S77 stainless alloy or MP35N (UNS R30035) outer armour wires engineered for abrasion resistance against casing shoes, open-hole ledges and winch Lebus grooves.
TEBAOFLEX workshop macro sample photograph of double contra-helical steel-wire-armoured 7-conductor wireline logging cable resting on white background showing outer and inner galvanized steel armour rings and 6+1 concentric copper cores
TEBAOFLEX real workshop sample: precision two-layer contra-helical steel wire armour around 7 concentric copper logging conductors.

Heptacable 7H42 / 7J46 / 7H47 / W7 Model Code Breakdown

  • 7H / 7J / W7: 7-conductor concentric heptacable family prefix (6 outer insulated copper conductors laid symmetrically around 1 central conductor)
  • 32 / 37 / 42 / 46 / 47: nominal cable outer diameter expressed in 1/100ths of an inch (0.325 in = 5/16 in, 0.380 in = 3/8 in, 0.426 in = 7/16 in, 0.464 in = 15/32 in, 0.474 in Slammer)
  • RP / BPP / SPK / RPK: modified copolymer polypropylene core insulation rated to 149–150 °C (300 °F) for standard sweet-well open-hole logging
  • F46PP / SFTK / RFTK / RZ: high-temperature fluoropolymer insulation packages (FEP+PP / FEP+ETFE rated to 232 °C, or dual fluoropolymer / PFA rated to 260 °C)
  • HS24 / HS28 / HS34 / Slammer: oversized outer-wire high-strength contra-helical armour builds delivering 109 kN (12.04 mm), 125 kN (12.45 mm) and 151 kN (13.20 mm) breaking load
Applications

Heptacable Open-Hole Formation Evaluation, HPHT & Offshore Logging Applications

Deploy 7H, 7J and W7 7-conductor heptacables across land logging trucks, offshore jack-up and drillship wireline skids, geothermal boreholes and deviated open-hole formation evaluation campaigns.

Offshore wireline logging skid drum and wellhead sheave assembly spooling bare double-armoured 7-conductor heptacable wireline cable over an upper lubricator sheave on a drilling rig
Offshore and land wireline logging winch payout of 15/32 in and 7/16 in double-armoured heptacable over calibrated upper/lower sheaves.
  • Comprehensive open-hole triple-combo and quad-combo formation evaluation (array induction resistivity, dipole sonic, litho-density, neutron porosity and borehole micro-imagers).
  • Modular formation dynamics testing (fluid sampling), rotary sidewall coring and nuclear magnetic resonance (NMR) tool strings requiring continuous high DC/AC surface power.
  • High-dogleg, sticky and ultra-deep (6,000 to 9,000 m) offshore wells utilizing 0.474 in Slammer (109 kN), 0.490 in (125 kN) and 0.520 in (151 kN) heavy-pull heptacables for overpull safety margin.
  • Slim-hole open-hole logging and multi-parameter cased-hole production logging using 1/4 in (6.40 mm) and 5/16 in (8.26 mm) fluoropolymer heptacables through lubricator grease injection heads.

Heptacable vs Monoconductor vs 4-Core Quad vs FIMT Optical Wireline

7-Conductor Heptacable vs Monoconductor vs 4-Conductor Quad vs Electro-Optical FIMT Wireline Selection
Wireline FamilyCore Geometry & ODTelemetry & Power CapacityPrimary Wellbore Duty
7-Conductor Heptacable (7H42 / 7J46 / W7, this page)6+1 copper cores | 6.40 to 13.20 mm ODHigh multi-bus power + high-rate multi-pair digital telemetryOpen-hole quad-combo, imaging, NMR, MDT fluid sampling & rotary coring
Monoconductor E-Line (1N22 / 1N32)1 central copper core | 3.18 to 9.65 mm ODSingle-channel power/telemetry with armour returnLive-well cased-hole perforating, plug-and-perf, PLT & grease pack-off runs
4-Conductor Quad Borehole (4H18 / A240250)4 star-quad copper cores | 4.72 to 7.94 mm ODBalanced 2-pair differential signal + moderate tool powerMineral exploration slim boreholes, hydrogeology, acoustic & borehole TV
Electro-Optical FIMT Wireline (4SSA27 / FIMT-EO)SM/MM fibres in SS/Alloy 825 tube + optional Cu | 3.18 to 11.80 mmGigabit optical bandwidth + distributed DTS / DAS sensingReal-time DTS/DAS fracture diagnostics, geothermal & ultra-high-rate imaging

Use 0.474 in (7H47 / W7BPP-HS24-12.04) or 0.520 in (W7PP-HS34-13.2) outer heavy-wire Slammer heptacables whenever open-hole differential sticking or dogleg key-seating requires > 100 kN breaking strength.

Heptacable 7-Conductor Wireline Logging Cable RFQ Ordering Checklist

  • Target model or inch/metric OD class (for example 7/16 in 10.82 mm 7H42, 15/32 in 11.80 mm 7J46 / W7BPP-11.8, or 0.474 in 12.04 mm 7H47 Slammer) to match existing winch Lebus grooves and grease tubes.
  • Maximum bottomhole temperature (150 °C copolymer PP, 232 °C FEP/PP or FEP/ETFE, or 260 °C fluoropolymer PFA/ETFE).
  • Wellbore fluid chemistry: standard sweet mud/brine (GIPS/GEIPS steel armour) or sour H2S/CO2 partial pressure requiring S75/S77 alloy or MP35N (UNS R30035) armour.
  • Required minimum breaking strength (kN or lbf), maximum working tension and minimum logging sheave diameter.
  • Continuous splice-free reel length (for example 50 m test length, 3,500 m land drum or 7,500 to 9,500 m offshore skid reel; MOQ 50 m, lead time 7 to 45 working days).

Related selection resources

Heptacable 7-Conductor Wireline Logging Cable Frequently Asked Questions

What is the difference between 7/16 in (7H42), 15/32 in (7J46 / W7BPP-11.8) and 0.474 in (7H47 Slammer) heptacable wireline logging cables?

10.82 mm, 11.80 mm and 12.04 mm in nominal outer diameter, stepping breaking strength up from 78.3 kN to 85–91.2 kN and 109.0 kN respectively. While 7H42 (7/16 in) reduces drum weight for medium-depth rigs and 7J46 / W7BPP-11.8 (15/32 in) is the global open-hole standard, 7H47 / W7BPP-HS24-12.04 uses oversized 1.66 mm outer armour wires for crush resistance and high-tension pull-free margin in sticky deviated wells.

Which heptacable insulation rating should be specified for 200 °C to 260 °C HPHT open-hole logging?

232 °C (450 °F) composite FEP/PP or FEP/ETFE models (such as W7F46PP-11.8, 7SFTK and 7RFTK) cover bottomhole temperatures up to 205–232 °C, whereas 260 °C (500 °F) nickel-coated copper dual-fluoropolymer or PFA models (7H42RZ, W7F46F40PP-11.8 and W7PFA-6.4) are required from 232 °C to 260 °C.

Can TEBAOFLEX supply 7-conductor heptacables with corrosion-resistant armour for H2S sour wells?

Yes. In addition to Galvanized Extra Improved Plow Steel (GEIPS) for sweet wells, TEBAOFLEX manufactures 7H and W7 heptacables with S75/S77 stainless alloy armour for moderate H2S/CO2 service and MP35N (UNS R30035) nickel-cobalt-chromium-molybdenum superalloy armour for severe sour HPHT wells.

Are W7BPP-11.8 and W7F46PP-11.8 physically interchangeable with 15/32 in 7J46 and 7RPK logging drums and sheaves?

Yes. Both W7BPP-11.8 / W7F46PP-11.8 (11.80 ± 0.10 mm) and 15/32 in 7J46 / 7RPK (0.464 in / 11.79 mm) share the same 15/32 inch nominal OD envelope, 7x20–17 AWG 6+1 electrical core layout and >= 504 to 610 mm sheave geometry.

What are the minimum order quantity and delivery lead time for 7-conductor heptacable wireline cables?

50 m minimum order quantity (MOQ), with a production lead time of 7 to 45 working days for both short calibration reels and continuous 3,000 to 9,500 m splice-free logging lengths.

Specifications

Heptacable 7H, 7J & W7 Dimensional, Electrical & Breaking-Load Specifications

Heptacable Key Voltage, Temperature, Sheave & Tensile Summary

  • Full 7-conductor OD range: 1/4 in (6.40 mm), 5/16 in (8.26 mm), 3/8 in (9.65 mm), 7/16 in (10.82 mm), 15/32 in (11.80 mm), 0.474 in (12.04 mm), 0.490 in (12.45 mm) and 0.520 in (13.20 mm)
  • Three thermal insulation tiers: Modified copolymer PP rated to 150 °C (300 °F), composite FEP/PP or FEP/ETFE to 232 °C (450 °F), and high-temperature FEP/ETFE or PFA to 260 °C (500 °F)
  • High-pull Slammer & ultra-deep builds: 18/18, 18/24, 20/26 and 24/24 preformed contra-helical armour packages delivering 109 kN (0.474 in), 125 kN (0.490 in) and 151 kN (0.520 in) breaking strength
  • Sweet & H2S sour-well metallurgy: Galvanized Improved / Extra Improved Plow Steel (GIPS/GEIPS) for standard wells, or corrosion-resistant S75/S77 stainless alloy and MP35N (UNS R30035) for H2S/CO2
  • Custom & short-drum supply: Minimum order quantity 50 m (including test reels, offshore skid drums and 3,000 to 9,000 m logging lengths) produced in 7 to 45 working days
Heptacable 7H42, 7J46 & W7 7-Conductor Double-Armoured Wireline Logging Cable (1–1.5 kV DC) technical data
ParameterValue
Rated voltage1,000 V DC to 1,500 V DC conductor-to-armour with insulation resistance 500 to 15,000 MΩ·km at 500 V DC
Core configuration and gauges7 conductors (1 central + 6 concentric outer cores) in 24 AWG, 22 AWG, 20 AWG, 19 AWG and 17 AWG tinned or nickel-coated copper
Continuous temperature classes150 °C (300 °F) copolymer PP, 232 °C (450 °F) FEP/PP or FEP/ETFE, and 260 °C (500 °F) high-temperature fluoropolymer
Outer diameter and breaking load6.40 mm (1/4 in, 25 kN) through 10.82 mm (7/16 in, 78.3 kN), 11.80 mm (15/32 in, 85 to 91.2 kN) and 13.20 mm (0.520 in, 151 kN)
Minimum bend diameter and supply350 mm to 670 mm minimum sheave diameter with MOQ 50 m and 7 to 45 working days factory lead time
Armour metallurgy optionsPreformed GIPS / GEIPS galvanized steel (sweet wells), S75/S77 alloy steel (moderate H2S/CO2) or MP35N UNS R30035 superalloy (severe sour service)
Electrical telemetry balanceTypical DC resistance 26.5 to 84.3 Ω/km at 20 °C, capacitance 130 to 160 pF/m at 1 kHz, shield equilibrium within 30 mV

Heptacable 7H, 7J & W7 7-Conductor Wireline Logging Dimensional & Tensile Schedule

7-Conductor (Heptacable) Double-Armoured Wireline Logging Cable — Dimensional, Electrical & Mechanical Schedule
Model & Inch ClassNominal OD (mm)Conductor & Armour BuildTemp. Options (°C)DC Resistance | Cap. (Ω/km | pF/m)Weight in Air (kg/km)Min. Sheave | Breaking Load (mm | kN)Next step
W7F46-6.4 / A270250 Slim Heptacable (1/4 in)6.40 ± 0.107x(7x0.21 Cu) | 18x0.63 + 18x0.89 SWA150 / 232 / 26084.3 | 140160–185350 | 25.0Request this size
7H32RP / 7H32RZ Heptacable (5/16 in)8.26 ± 0.107x22 AWG Cu | 18 + 18 Contra-Helical SWA149 / 26051.8 | 180272–280460 | 42.3Request this size
7H37 / 7SPK / A276374 Heptacable (3/8 in)9.65 ± 0.107x22 AWG Cu | 18x1.04 + 24x1.04 SWA149 / 232 / 26050.8 | 145362–380480 | 62.3Request this size
7H42RP / 7H42RZ / 7SFTK (7/16 in)10.82 ± 0.107x20 AWG Cu | 18x1.16 + 24x1.16 SWA149 / 232 / 26032.2 | 174460–473610 | 78.3Request this size
7J46 / W7BPP-11.8 / 7RPK Heptacable (15/32 in)11.80 ± 0.107x(7x0.33 Cu) | 24x0.99 + 24x1.26 SWA15033.0 | 130500504 | 85.0–91.2Request this size
W7F46PP-11.8 / 7RFTK HT Heptacable (15/32 in)11.80 ± 0.107x(7x0.33 Ni/Sn-Cu) | 24x0.99 + 24x1.26 SWA232 / 26033.0 | 130509–512504 | 85.0–95.0Request this size
7H47 / W7BPP-HS24-12.04 Slammer (0.474 in)12.04 ± 0.107x(7x0.33 Cu) | 18x1.19 + 18x1.66 Heavy SWA150 / 232 / 26033.0 | 160565–589670 | 109.0Request this size
W7PP-HS28-12.4 Ultra-Deep Heptacable (0.490 in)12.45 ± 0.107x19 AWG Cu | 22x1.11 + 22x1.44 Heavy SWA150 / 232 / 26026.5 | 160571–589670 | 125.0Request this size
W7PP-HS34-13.2 Heavy-Pull Heptacable (0.520 in)13.20 ± 0.107x(7x0.33 Cu) | 16x1.50 + 20x1.67 Ultra SWA150 / 232 / 26033.0 | 130690–710670 | 151.0Request this size

Heptacable Insulation Temperature & Sour-Service Armour Material Matrix

7-Conductor Heptacable Insulation Code & Downhole Armour Metallurgy Selection Matrix
Insulation / Armour SuffixPolymer / Alloy SystemConductor PlatingContinuous Bottomhole Rating (°C / °F)Target Wellbore Environment
RP / BPP / SPK / RPKModified Copolymer Polypropylene (PP)Tinned Copper (ASTM B 33)150 °C / 300 °FStandard land & offshore open-hole / cased-hole logging
F46PP / SFTK / RFTKComposite FEP + Polypropylene or FEP + ETFETinned or Nickel-Coated Cu232 °C / 450 °FDeep HPHT oil & gas exploration and high-power imaging suites
RZ / F46F40 / PFADual Fluoropolymer (FEP/ETFE) or Pure PFANickel-Coated Cu (ASTM B 355 Cl.10)260 °C / 500 °FUltra-deep gas, thermal recovery & geothermal logging
GIPS / GEIPS (Standard)Galvanized Extra Improved Plow SteelPreformed + Pressure SealantUp to 205 °C mechanicalSweet wells without H2S sulphide stress cracking risk
S75 / S77 / MP35N (UNS R30035)Corrosion-Resistant Alloy / Ni-Co-Cr-Mo SuperalloyNickel-Coated Cu + Fluoropolymer163 to 260 °C in H2S + CO2Sour gas, high-chloride brine & acid-stimulated wellbores

Maximum suggested continuous working tension is 50% of nominal fixed-end cable breaking strength (for example 42.5 kN on W7BPP-11.8, 55.0 kN on 0.474 in W7BPP-HS24-12.04 and 75.5 kN on 0.520 in W7PP-HS34-13.2).

All heptacables are pre-stressed, torque-balanced and hot-stretched during armouring, with cable stretch coefficients controlled between 0.61 m/km/5 kN (13.20 mm) and 0.80 m/km/5 kN (11.80 mm) for repeatable depth correlation.

Minimum order quantity is 50 m with a production lead time of 7 to 45 working days, supporting both short calibration/test drums and continuous splice-free 4,000 to 9,500 m offshore logging reels.

ASCII part references: 7H32RP; 7H32RZ; 7H37; 7Q38RAZB; 7H42RP; 7H42RZ; 7J46; 7H47; 7SPK; 7STK; 7SFTK; 7RPK; 7RFTK; 7DFTK; W7B-6.4; W7F46-6.4; W7PFA-6.4; W7BPP-11.8; W7F46PP-11.8; W7BPP-HS24-12.04; W7PP-HS28-12.4; W7PP-HS34-13.2; A270250; A276374; A276422; A276463.

Standards

Heptacable Conductor, Dielectric & Sour-Service Metallurgy Standards

Heptacable 7H42, 7J46 & W7 7-Conductor Double-Armoured Wireline Logging Cable (1–1.5 kV DC) standards and test references
Standard or specificationApplication
ASTM B 33 & ASTM B 355 Class 10Tinned soft copper stranding for 150 to 205 °C logging cores and heavy nickel-coated copper stranding for 232 to 260 °C fluoropolymer cores.
ISO 15156 / NACE MR0175 (Sour-Service Alloy Builds)Metallurgical selection of S75/S77 stainless alloy and MP35N (UNS R30035) contra-helical armour wires resisting H2S sulphide stress cracking.
IEC 60228 & Concentric 6+1 Telemetry SymmetryControlled DC conductor resistance, <= 30 mV shield equilibrium, <= 100 mV interference balance and >= 15,000 MΩ·km insulation resistance on PP/FEP 15/32 in builds.

Certifications and document support

TEBAOFLEX ISO 9001 quality system, high-voltage spark/IR dielectric and tensile break-load test documentation

ISO 15156-3 — Cracking-resistant CRAs and nickel-cobalt alloys for H2S-containing oil and gas environments

ASTM B 355 — Standard specification for nickel-coated soft or annealed copper wire in high-temperature cores

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.