Heptacable 7H42, 7J46 & W7 7-Conductor Double-Armoured Wireline Logging Cable (1–1.5 kV DC)
Heptacable 7-conductor wireline logging cables (7H32, 7H37, 7H42, 7J46, 7H47 Slammer and W7 series, 1,000 to 1,500 V DC) combine a 6+1 concentric core of stranded copper conductors insulated with modified copolymer polypropylene (150 °C) or FEP/ETFE/PFA fluoropolymers (205 to 260 °C) inside double contra-helical GIPS or sour-service alloy wire armour (6.40 to 13.20 mm OD, 25 to 151 kN breaking strength).
Heptacable 7-conductor double-armoured wireline logging cables (7H32, 7H37, 7H42, 7J46, 7H47 and W7 series) are the primary open-hole formation-evaluation and offshore deep-well logging workhorses, delivering multi-channel 1,000 to 1,500 V DC downhole tool power and simultaneous high-speed telemetry across outer diameters from 6.40 mm (1/4 in) to 13.20 mm (0.520 in) and breaking loads from 25 kN to 151 kN.
Inside every heptacable, six outer insulated stranded tinned or nickel-coated copper conductors (22 AWG to 17 AWG) are laid concentrically around one central seventh conductor over water-blocked void fillers so differential telemetry pairs, orthogonal tool-power buses and armour return paths operate with <= 30 mV shield equilibrium and 130 to 160 pF/m capacitance at 1 kHz. Preformed contra-helical inner and outer steel armour layers with inter-armour pressure-sealing compound control rotational torque and cable stretch (0.61 to 2.80 m/km/5 kN) during high-tension spudding, rotary sidewall coring and differential-sticking pull-free operations.
Select 7H42 (7/16 in, 10.82 mm, 78.3 kN) or 7J46 / W7BPP-11.8 (15/32 in, 11.80 mm, 85 to 91.2 kN) for standard land and offshore open-hole logging suites, upgrade to 0.474 in 7H47 / W7BPP-HS24-12.04 Slammer (109 kN) or 0.520 in W7PP-HS34-13.2 (151 kN) for high-deviation sticky wellbores, or step down to 1/4 in W7F46-6.4 (6.40 mm) for slim-hole and through-tubing multi-sensor runs. For single-core cased-hole perforating see our Monoconductor Wireline Logging Cable, or for optical DTS/DAS sensing see our 4SSA27 & FIMT-EO Electro-Optical Wireline Cable.
Explore the oil, gas and petrochemical cable range for related configurations.
Heptacable 7H, 7J & W7 6+1 Core & Preformed Double-Armour Construction
Each TEBAOFLEX 7-conductor heptacable is manufactured with water-blocked 7-wire copper strands, concentric pinhole-free extruded thermoplastic or fluoropolymer insulation, elastomeric bedding filler and stress-relieved preformed contra-helical wire armour engineered to hold roundness under multi-layer winch spooling and grease-head pack-off pressure.

| Component | Material and construction |
|---|---|
| 1. Water-Blocked Stranded Conductors (6 + 1 Concentric Core) | Seven 7-wire stranded tinned copper conductors per ASTM B 33 (up to 205 °C) or ASTM B 355 Class 10 nickel-coated copper (up to 260 °C), 7x0.21 mm to 7x0.33 mm / 22 to 17 AWG, with internal strand voids sealed against downhole gas and fluid migration. |
| 2. Temperature-Graded Core Insulation (150 °C / 232 °C / 260 °C) | Modified copolymer polypropylene (PP, 150 °C / 300 °F) for standard gradients, dual-extruded FEP + copolymer PP or FEP + ETFE (232 °C / 450 °F) for deep HPHT wells, or pure FEP/ETFE and PFA fluoropolymer walls (260 °C / 500 °F) for extreme geothermal and ultra-deep boreholes. |
| 3. 6+1 Symmetrical Cabling & Void-Free Matrix | Six colour-coded/numbered outer insulated cores helically laid around one central core with high-temperature polymeric valley fillers and binder tape to preserve low crosstalk and uniform radial compression support. |
| 4. Inner Preformed Steel or Alloy Wire Armour + Pressure Sealant | 16 to 24 right-hand preformed high-tensile galvanized plow steel (GIPS/GEIPS) or sour-service corrosion-resistant alloy wires embedded in high-temperature anti-corrosion and pressure-sealing compound to block annular gas migration. |
| 5. Outer Contra-Helical Preformed Wire Armour (Torque-Balanced) | 18 to 26 left-hand heavy-diameter preformed GIPS/GEIPS, S75/S77 stainless alloy or MP35N (UNS R30035) outer armour wires engineered for abrasion resistance against casing shoes, open-hole ledges and winch Lebus grooves. |

Heptacable 7H42 / 7J46 / 7H47 / W7 Model Code Breakdown
- 7H / 7J / W7: 7-conductor concentric heptacable family prefix (6 outer insulated copper conductors laid symmetrically around 1 central conductor)
- 32 / 37 / 42 / 46 / 47: nominal cable outer diameter expressed in 1/100ths of an inch (0.325 in = 5/16 in, 0.380 in = 3/8 in, 0.426 in = 7/16 in, 0.464 in = 15/32 in, 0.474 in Slammer)
- RP / BPP / SPK / RPK: modified copolymer polypropylene core insulation rated to 149–150 °C (300 °F) for standard sweet-well open-hole logging
- F46PP / SFTK / RFTK / RZ: high-temperature fluoropolymer insulation packages (FEP+PP / FEP+ETFE rated to 232 °C, or dual fluoropolymer / PFA rated to 260 °C)
- HS24 / HS28 / HS34 / Slammer: oversized outer-wire high-strength contra-helical armour builds delivering 109 kN (12.04 mm), 125 kN (12.45 mm) and 151 kN (13.20 mm) breaking load
Heptacable Open-Hole Formation Evaluation, HPHT & Offshore Logging Applications
Deploy 7H, 7J and W7 7-conductor heptacables across land logging trucks, offshore jack-up and drillship wireline skids, geothermal boreholes and deviated open-hole formation evaluation campaigns.

- Comprehensive open-hole triple-combo and quad-combo formation evaluation (array induction resistivity, dipole sonic, litho-density, neutron porosity and borehole micro-imagers).
- Modular formation dynamics testing (fluid sampling), rotary sidewall coring and nuclear magnetic resonance (NMR) tool strings requiring continuous high DC/AC surface power.
- High-dogleg, sticky and ultra-deep (6,000 to 9,000 m) offshore wells utilizing 0.474 in Slammer (109 kN), 0.490 in (125 kN) and 0.520 in (151 kN) heavy-pull heptacables for overpull safety margin.
- Slim-hole open-hole logging and multi-parameter cased-hole production logging using 1/4 in (6.40 mm) and 5/16 in (8.26 mm) fluoropolymer heptacables through lubricator grease injection heads.
Heptacable vs Monoconductor vs 4-Core Quad vs FIMT Optical Wireline
| Wireline Family | Core Geometry & OD | Telemetry & Power Capacity | Primary Wellbore Duty |
|---|---|---|---|
| 7-Conductor Heptacable (7H42 / 7J46 / W7, this page) | 6+1 copper cores | 6.40 to 13.20 mm OD | High multi-bus power + high-rate multi-pair digital telemetry | Open-hole quad-combo, imaging, NMR, MDT fluid sampling & rotary coring |
| Monoconductor E-Line (1N22 / 1N32) | 1 central copper core | 3.18 to 9.65 mm OD | Single-channel power/telemetry with armour return | Live-well cased-hole perforating, plug-and-perf, PLT & grease pack-off runs |
| 4-Conductor Quad Borehole (4H18 / A240250) | 4 star-quad copper cores | 4.72 to 7.94 mm OD | Balanced 2-pair differential signal + moderate tool power | Mineral exploration slim boreholes, hydrogeology, acoustic & borehole TV |
| Electro-Optical FIMT Wireline (4SSA27 / FIMT-EO) | SM/MM fibres in SS/Alloy 825 tube + optional Cu | 3.18 to 11.80 mm | Gigabit optical bandwidth + distributed DTS / DAS sensing | Real-time DTS/DAS fracture diagnostics, geothermal & ultra-high-rate imaging |
Use 0.474 in (7H47 / W7BPP-HS24-12.04) or 0.520 in (W7PP-HS34-13.2) outer heavy-wire Slammer heptacables whenever open-hole differential sticking or dogleg key-seating requires > 100 kN breaking strength.
Heptacable 7-Conductor Wireline Logging Cable RFQ Ordering Checklist
- Target model or inch/metric OD class (for example 7/16 in 10.82 mm 7H42, 15/32 in 11.80 mm 7J46 / W7BPP-11.8, or 0.474 in 12.04 mm 7H47 Slammer) to match existing winch Lebus grooves and grease tubes.
- Maximum bottomhole temperature (150 °C copolymer PP, 232 °C FEP/PP or FEP/ETFE, or 260 °C fluoropolymer PFA/ETFE).
- Wellbore fluid chemistry: standard sweet mud/brine (GIPS/GEIPS steel armour) or sour H2S/CO2 partial pressure requiring S75/S77 alloy or MP35N (UNS R30035) armour.
- Required minimum breaking strength (kN or lbf), maximum working tension and minimum logging sheave diameter.
- Continuous splice-free reel length (for example 50 m test length, 3,500 m land drum or 7,500 to 9,500 m offshore skid reel; MOQ 50 m, lead time 7 to 45 working days).
Related selection resources
- Oil, gas and downhole wireline cable product catalog
- Oil and gas drilling, offshore and downhole cable selection guide
- Monoconductor (1-Core) Double-Armoured Wireline Logging & Perforating Cable
- Sour-Service H2S Corrosion-Resistant Alloy Wireline Logging Cable
- High-Temperature Fluoropolymer HPHT & Geothermal Wireline Cable
- Engineering guide: Monoconductor vs 4-Core Quad vs 7-Core Heptacable & Electro-Optical Wireline Selection
Heptacable 7-Conductor Wireline Logging Cable Frequently Asked Questions
What is the difference between 7/16 in (7H42), 15/32 in (7J46 / W7BPP-11.8) and 0.474 in (7H47 Slammer) heptacable wireline logging cables?
10.82 mm, 11.80 mm and 12.04 mm in nominal outer diameter, stepping breaking strength up from 78.3 kN to 85–91.2 kN and 109.0 kN respectively. While 7H42 (7/16 in) reduces drum weight for medium-depth rigs and 7J46 / W7BPP-11.8 (15/32 in) is the global open-hole standard, 7H47 / W7BPP-HS24-12.04 uses oversized 1.66 mm outer armour wires for crush resistance and high-tension pull-free margin in sticky deviated wells.
Which heptacable insulation rating should be specified for 200 °C to 260 °C HPHT open-hole logging?
232 °C (450 °F) composite FEP/PP or FEP/ETFE models (such as W7F46PP-11.8, 7SFTK and 7RFTK) cover bottomhole temperatures up to 205–232 °C, whereas 260 °C (500 °F) nickel-coated copper dual-fluoropolymer or PFA models (7H42RZ, W7F46F40PP-11.8 and W7PFA-6.4) are required from 232 °C to 260 °C.
Can TEBAOFLEX supply 7-conductor heptacables with corrosion-resistant armour for H2S sour wells?
Yes. In addition to Galvanized Extra Improved Plow Steel (GEIPS) for sweet wells, TEBAOFLEX manufactures 7H and W7 heptacables with S75/S77 stainless alloy armour for moderate H2S/CO2 service and MP35N (UNS R30035) nickel-cobalt-chromium-molybdenum superalloy armour for severe sour HPHT wells.
Are W7BPP-11.8 and W7F46PP-11.8 physically interchangeable with 15/32 in 7J46 and 7RPK logging drums and sheaves?
Yes. Both W7BPP-11.8 / W7F46PP-11.8 (11.80 ± 0.10 mm) and 15/32 in 7J46 / 7RPK (0.464 in / 11.79 mm) share the same 15/32 inch nominal OD envelope, 7x20–17 AWG 6+1 electrical core layout and >= 504 to 610 mm sheave geometry.
What are the minimum order quantity and delivery lead time for 7-conductor heptacable wireline cables?
50 m minimum order quantity (MOQ), with a production lead time of 7 to 45 working days for both short calibration reels and continuous 3,000 to 9,500 m splice-free logging lengths.
Heptacable 7H, 7J & W7 Dimensional, Electrical & Breaking-Load Specifications
Heptacable Key Voltage, Temperature, Sheave & Tensile Summary
- Full 7-conductor OD range: 1/4 in (6.40 mm), 5/16 in (8.26 mm), 3/8 in (9.65 mm), 7/16 in (10.82 mm), 15/32 in (11.80 mm), 0.474 in (12.04 mm), 0.490 in (12.45 mm) and 0.520 in (13.20 mm)
- Three thermal insulation tiers: Modified copolymer PP rated to 150 °C (300 °F), composite FEP/PP or FEP/ETFE to 232 °C (450 °F), and high-temperature FEP/ETFE or PFA to 260 °C (500 °F)
- High-pull Slammer & ultra-deep builds: 18/18, 18/24, 20/26 and 24/24 preformed contra-helical armour packages delivering 109 kN (0.474 in), 125 kN (0.490 in) and 151 kN (0.520 in) breaking strength
- Sweet & H2S sour-well metallurgy: Galvanized Improved / Extra Improved Plow Steel (GIPS/GEIPS) for standard wells, or corrosion-resistant S75/S77 stainless alloy and MP35N (UNS R30035) for H2S/CO2
- Custom & short-drum supply: Minimum order quantity 50 m (including test reels, offshore skid drums and 3,000 to 9,000 m logging lengths) produced in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 1,000 V DC to 1,500 V DC conductor-to-armour with insulation resistance 500 to 15,000 MΩ·km at 500 V DC |
| Core configuration and gauges | 7 conductors (1 central + 6 concentric outer cores) in 24 AWG, 22 AWG, 20 AWG, 19 AWG and 17 AWG tinned or nickel-coated copper |
| Continuous temperature classes | 150 °C (300 °F) copolymer PP, 232 °C (450 °F) FEP/PP or FEP/ETFE, and 260 °C (500 °F) high-temperature fluoropolymer |
| Outer diameter and breaking load | 6.40 mm (1/4 in, 25 kN) through 10.82 mm (7/16 in, 78.3 kN), 11.80 mm (15/32 in, 85 to 91.2 kN) and 13.20 mm (0.520 in, 151 kN) |
| Minimum bend diameter and supply | 350 mm to 670 mm minimum sheave diameter with MOQ 50 m and 7 to 45 working days factory lead time |
| Armour metallurgy options | Preformed GIPS / GEIPS galvanized steel (sweet wells), S75/S77 alloy steel (moderate H2S/CO2) or MP35N UNS R30035 superalloy (severe sour service) |
| Electrical telemetry balance | Typical DC resistance 26.5 to 84.3 Ω/km at 20 °C, capacitance 130 to 160 pF/m at 1 kHz, shield equilibrium within 30 mV |
Heptacable 7H, 7J & W7 7-Conductor Wireline Logging Dimensional & Tensile Schedule
| Model & Inch Class | Nominal OD (mm) | Conductor & Armour Build | Temp. Options (°C) | DC Resistance | Cap. (Ω/km | pF/m) | Weight in Air (kg/km) | Min. Sheave | Breaking Load (mm | kN) | Next step |
|---|---|---|---|---|---|---|---|
| W7F46-6.4 / A270250 Slim Heptacable (1/4 in) | 6.40 ± 0.10 | 7x(7x0.21 Cu) | 18x0.63 + 18x0.89 SWA | 150 / 232 / 260 | 84.3 | 140 | 160–185 | 350 | 25.0 | Request this size |
| 7H32RP / 7H32RZ Heptacable (5/16 in) | 8.26 ± 0.10 | 7x22 AWG Cu | 18 + 18 Contra-Helical SWA | 149 / 260 | 51.8 | 180 | 272–280 | 460 | 42.3 | Request this size |
| 7H37 / 7SPK / A276374 Heptacable (3/8 in) | 9.65 ± 0.10 | 7x22 AWG Cu | 18x1.04 + 24x1.04 SWA | 149 / 232 / 260 | 50.8 | 145 | 362–380 | 480 | 62.3 | Request this size |
| 7H42RP / 7H42RZ / 7SFTK (7/16 in) | 10.82 ± 0.10 | 7x20 AWG Cu | 18x1.16 + 24x1.16 SWA | 149 / 232 / 260 | 32.2 | 174 | 460–473 | 610 | 78.3 | Request this size |
| 7J46 / W7BPP-11.8 / 7RPK Heptacable (15/32 in) | 11.80 ± 0.10 | 7x(7x0.33 Cu) | 24x0.99 + 24x1.26 SWA | 150 | 33.0 | 130 | 500 | 504 | 85.0–91.2 | Request this size |
| W7F46PP-11.8 / 7RFTK HT Heptacable (15/32 in) | 11.80 ± 0.10 | 7x(7x0.33 Ni/Sn-Cu) | 24x0.99 + 24x1.26 SWA | 232 / 260 | 33.0 | 130 | 509–512 | 504 | 85.0–95.0 | Request this size |
| 7H47 / W7BPP-HS24-12.04 Slammer (0.474 in) | 12.04 ± 0.10 | 7x(7x0.33 Cu) | 18x1.19 + 18x1.66 Heavy SWA | 150 / 232 / 260 | 33.0 | 160 | 565–589 | 670 | 109.0 | Request this size |
| W7PP-HS28-12.4 Ultra-Deep Heptacable (0.490 in) | 12.45 ± 0.10 | 7x19 AWG Cu | 22x1.11 + 22x1.44 Heavy SWA | 150 / 232 / 260 | 26.5 | 160 | 571–589 | 670 | 125.0 | Request this size |
| W7PP-HS34-13.2 Heavy-Pull Heptacable (0.520 in) | 13.20 ± 0.10 | 7x(7x0.33 Cu) | 16x1.50 + 20x1.67 Ultra SWA | 150 / 232 / 260 | 33.0 | 130 | 690–710 | 670 | 151.0 | Request this size |
Heptacable Insulation Temperature & Sour-Service Armour Material Matrix
| Insulation / Armour Suffix | Polymer / Alloy System | Conductor Plating | Continuous Bottomhole Rating (°C / °F) | Target Wellbore Environment |
|---|---|---|---|---|
| RP / BPP / SPK / RPK | Modified Copolymer Polypropylene (PP) | Tinned Copper (ASTM B 33) | 150 °C / 300 °F | Standard land & offshore open-hole / cased-hole logging |
| F46PP / SFTK / RFTK | Composite FEP + Polypropylene or FEP + ETFE | Tinned or Nickel-Coated Cu | 232 °C / 450 °F | Deep HPHT oil & gas exploration and high-power imaging suites |
| RZ / F46F40 / PFA | Dual Fluoropolymer (FEP/ETFE) or Pure PFA | Nickel-Coated Cu (ASTM B 355 Cl.10) | 260 °C / 500 °F | Ultra-deep gas, thermal recovery & geothermal logging |
| GIPS / GEIPS (Standard) | Galvanized Extra Improved Plow Steel | Preformed + Pressure Sealant | Up to 205 °C mechanical | Sweet wells without H2S sulphide stress cracking risk |
| S75 / S77 / MP35N (UNS R30035) | Corrosion-Resistant Alloy / Ni-Co-Cr-Mo Superalloy | Nickel-Coated Cu + Fluoropolymer | 163 to 260 °C in H2S + CO2 | Sour gas, high-chloride brine & acid-stimulated wellbores |
Maximum suggested continuous working tension is 50% of nominal fixed-end cable breaking strength (for example 42.5 kN on W7BPP-11.8, 55.0 kN on 0.474 in W7BPP-HS24-12.04 and 75.5 kN on 0.520 in W7PP-HS34-13.2).
All heptacables are pre-stressed, torque-balanced and hot-stretched during armouring, with cable stretch coefficients controlled between 0.61 m/km/5 kN (13.20 mm) and 0.80 m/km/5 kN (11.80 mm) for repeatable depth correlation.
Minimum order quantity is 50 m with a production lead time of 7 to 45 working days, supporting both short calibration/test drums and continuous splice-free 4,000 to 9,500 m offshore logging reels.
ASCII part references: 7H32RP; 7H32RZ; 7H37; 7Q38RAZB; 7H42RP; 7H42RZ; 7J46; 7H47; 7SPK; 7STK; 7SFTK; 7RPK; 7RFTK; 7DFTK; W7B-6.4; W7F46-6.4; W7PFA-6.4; W7BPP-11.8; W7F46PP-11.8; W7BPP-HS24-12.04; W7PP-HS28-12.4; W7PP-HS34-13.2; A270250; A276374; A276422; A276463.
Heptacable Conductor, Dielectric & Sour-Service Metallurgy Standards
| Standard or specification | Application |
|---|---|
| ASTM B 33 & ASTM B 355 Class 10 | Tinned soft copper stranding for 150 to 205 °C logging cores and heavy nickel-coated copper stranding for 232 to 260 °C fluoropolymer cores. |
| ISO 15156 / NACE MR0175 (Sour-Service Alloy Builds) | Metallurgical selection of S75/S77 stainless alloy and MP35N (UNS R30035) contra-helical armour wires resisting H2S sulphide stress cracking. |
| IEC 60228 & Concentric 6+1 Telemetry Symmetry | Controlled DC conductor resistance, <= 30 mV shield equilibrium, <= 100 mV interference balance and >= 15,000 MΩ·km insulation resistance on PP/FEP 15/32 in builds. |
Certifications and document support
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
4H18, A240 & 6SSA5 4-Conductor Quad & Multi-Core Borehole Geophysical Logging Cable (300–1200 V)
A related cable option for a different application or duty profile.
View product4SSA27 & FIMT-EO Armoured Fiber-Optic & Hybrid Electro-Optical Wireline Logging Cable (DTS / DAS)
A related cable option for a different application or duty profile.
View productMonoconductor Wireline Logging Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.