KFF, KFFP, KFFRP, KFFP2-22 & DJFPFP 450/750 V Fluoroplastic Control & Computer Cable
KFF, KFFR, KFFP, KFFRP and steel-tape armoured KFFP2-22 450/750 V fluoroplastic control cables plus DJFPFP / DJFPVP 300/500 V individual-and-overall screened DCS computer cables (TF-KFF-KFFP-DJFPFP) withstand -60 °C to +200 °C (F46/FEP) or +260 °C (PFA) and concentrated acid/alkali mist. Built for overseas metallurgical, nickel-cobalt HPAL, chemical and power-plant EPC projects (2–37 cores & 1–24 pairs, 300 m MOQ).
KFF, KFFP, KFFRP, armoured KFFP2-22 450/750 V fluoroplastic control cables and DJFPFP 300/500 V individual-and-overall screened computer cables serve heavy industrial EPC projects across -60 °C to +260 °C, spanning 2×0.75 mm² solenoid leads up to 37×1.5 mm² switchgear trunks, 4×6.0 mm² CT circuits and 24x2x1.5 mm² DCS marshalling cables.
In Indonesian HPAL nickel-cobalt acid-leach plants, African copper-cobalt SX-EW solvent-extraction tankhouses, coking/sintering steelworks, chlor-alkali electrolysis halls and coal-chemical boilers, standard KVVP / KVVRP / DJYPVP PVC-sheathed cables embrittle in heat and dissolve in acid/organic mist. Upgrading both insulation and sheath to F46 (FEP, +200 °C) or PFA (+260 °C) delivers a 10x longer maintenance-free service life. Every production drum undergoes 2,500 V to 3,000 V AC 5-minute dielectric immersion testing and spark inspection before export dispatch.
Specify Class 1/2 rigid KFF / KFFP / KFFP2-22 for fixed cable ladders and armoured trench runs, Class 5 flexible KFFR / KFFRP for cabinet doors and vibrating skids, or dual-screened DJFPFP / DJFP2FP2 for low-noise 4–20 mA, HART and Modbus DCS I/O racks (MOQ 300 m per specification, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
KFF, KFFP, KFFP2-22 & DJFPFP Cable Construction
Manufactured to GB/T 9330 and TICW/06 industrial fluoroplastic control/instrumentation geometry with IEC 60228 copper conductors and 100 % spark/high-pot testing.

| Component | Material and construction |
|---|---|
| 1. Bare, Tinned or Silver/Nickel-Plated Copper Conductors | IEC 60228 Class 1 solid, Class 2 stranded (KFF / KFFP / KFFP2-22) or Class 5 flexible (KFFR / KFFRP / DJFPFPR) copper; tinned up to +200 °C, silver/nickel-plated up to +260 °C. |
| 2. Extruded F46 (FEP) or PFA Core Insulation | Number-coded or colour-coded fluoroplastic wall rated 450/750 V on KFF control series and 300/500 V on DJFPFP twisted-pair computer series. |
| 3. Individual / Overall EMC Screening (P / P2 / P3) | Copper wire braid (P >= 80–85 %), copper tape wrap (P2) or aluminium-polyester foil + drain wire (P3); individual pair + overall dual screens on DJFPFP. |
| 4. Fluoroplastic Bedding, Optional Steel Tape Armour (22) & Outer Sheath | PTFE/fibreglass thermal wrap, extruded F46/PFA inner bedding + double galvanized steel tape armour on -22 models, and acid/flame-proof F46/PFA outer sheath. |
KFF / KFFP / KFFP2-22 & DJFPFP Designation Code Guide
- K / DJ: K = 450/750 V control cable; DJ = 300/500 V electronic computer / DCS twisted-pair cable
- FF (F46 / PFA): Fluoroplastic core insulation (first F) + fluoroplastic outer sheath (second F), +200 °C or +260 °C
- R: IEC 60228 Class 5 flexible stranded copper conductor (omit R for Class 1/2 fixed installation)
- P / P2 / P3: EMC screen: P = copper wire braid, P2 = copper tape, P3 = Al/PET foil (DJFPFP = pair + overall screens)
- 22: Double galvanized steel tape armour over fluoroplastic inner bedding for crush/trench protection
KFF & DJFPFP HPAL Nickel, SX-EW Copper & Chemical EPC Duty
Engineered for EPC contractors, design institutes and plant maintenance teams operating corrosive, high-ambient industrial facilities.

- HPAL nickel-cobalt autoclaves, copper-cobalt SX-EW electrowinning tankhouses, sulfuric acid plants and phosphoric/hydrofluoric chemical units.
- Blast-furnace tuyere platforms, continuous casting run-out tables, coke-oven gas boosters and cement rotary-kiln preheater towers.
- Thermal power-plant boiler burner management systems (BMS), sootblower controls, FGD wet-scrubber dampers and ESP precipitator hoppers.
- Petrochemical DCS / SIS / PLC analog 4–20 mA, HART, Foundation Fieldbus and RS-485 instrumentation marshalling (DJFPFP / DJFP2FP2).
KFF / KFFP2-22 vs DJFPFP vs PAS 5308 Selection Guide
| Cable Series | Rated Voltage | Screen & Armour Architecture | Target Circuit Duty |
|---|---|---|---|
| KFF / KFFP / KFFRP (this page) | 450/750 V | Unscreened or overall Cu braid | 200–260 °C contactor, valve, damper & CT control circuits |
| KFFP2-22 / KFF22 (this page) | 450/750 V | Cu tape + double steel tape armour | Direct-buried trenches, crush zones & smelter pipe racks |
| DJFPFP / DJFP2FP2 (this page) | 300/500 V | Individual pair + overall dual screen | 4–20 mA, HART, thermocouple-to-DCS & RS-485 analog pairs |
| PAS 5308 / BS 5308 | 300/500 V | XLPE/PE + Al/PET foil (+90 °C max) | Ambient petrochemical zones below +90 °C without acid mist |
For 0.6/1 kV motor power feeders above 6 mm² in the same hot/acidic zone, pair KFFP/DJFPFP with our 0.6/1 kV FEP/PFA GSWB steel-wire-braided power cable.
KFF & DJFPFP Fluoroplastic Control Cable RFQ Checklist
- Exact model designation (KFF, KFFR, KFFP, KFFRP, KFFP2-22, DJFPFP, DJFPFRP or DJFP2FP2) and flame class (ZA/ZB/ZC).
- Core count x mm² (for example 7x1.5, 19x1.5) or pair count x 2 x mm² (for example 4x2x1.0, 8x2x1.5).
- Operating temperature tier: +200 °C (F46/FEP + tinned copper) or +260 °C (PFA + silver/nickel-plated copper).
- Project drum lengths (MOQ 300 m per item, export fumigated/steel drums, 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Fluoropolymer & Industrial Cables
- Compare European VDE FEP-6Y & FEP-C-6Y Multi-Core Control Cable
- Compare North American 600 V AWG FEP & ETFE Multiconductor Cable
- View Screened Multi-Pair KX/JX/TX/EX Fluoroplastic Thermocouple Cable
- Engineering guide: Collective vs individual+collective instrumentation screens
KFF, KFFP, KFFRP & DJFPFP Cable Frequently Asked Questions
What does each letter mean in KFF, KFFP, KFFRP, KFFP2-22 and DJFPFP?
In KFFP2-22: K = control cable (450/750 V), first F = fluoroplastic F46/PFA insulation, second F = fluoroplastic outer sheath, R = Class 5 flexible conductor, P = copper wire braid (P2 = copper tape), and 22 = double steel tape armour. In DJFPFP: DJ = DCS/computer instrumentation cable (300/500 V), F = fluoroplastic insulation, first P = individual pair copper braid, second F = fluoroplastic sheath, and final P = overall screen.
When should I specify DJFPFP instead of KFFP?
Specify DJFPFP (300/500 V twisted pairs with individual + overall screens) for low-level 4–20 mA, HART, pulse and RS-485 DCS signals where pair-to-pair capacitive crosstalk must be blocked; specify KFFP (450/750 V laid-up cores) for 110–230 V AC/DC relay, solenoid, valve and CT circuits.
Why do HPAL nickel-cobalt and SX-EW copper projects specify KFFP and DJFPFP?
Sulfuric acid mist + organic solvent extractants + tropical 55 °C–180 °C vessel heat rapidly crack PVC and swell rubber sheaths, whereas all-fluoroplastic F46/FEP (+200 °C) and PFA (+260 °C) sheaths remain chemically inert and flame-retardant.
Can KFFP2-22 and DJFPFP-22 be installed directly in outdoor trenches or corrosive racks?
Yes — double galvanized steel tape armour (22) sealed beneath an outer F46 fluoroplastic oversheath provides both high radial crush/rodent protection and external acid/alkali corrosion immunity (use stainless steel wire braid SSWB where high tensile pulling or flexing is required).
What is the minimum order quantity and delivery time for KFF and DJFPFP export EPC orders?
300 m per specification is our standard factory production MOQ, supplied on export-ready drums with routine dielectric and conductor resistance test certificates in 7 to 45 working days.
KFF / KFFP / KFFP2-22 (450/750 V) & DJFPFP Schedules
KFF & DJFPFP Voltage, Screening, Armour & Drum Summary
- Complete EPC control & DCS family: Covers unscreened KFF/KFFR, braided KFFP/KFFRP, copper-tape/steel-tape armoured KFFP2-22 and dual-screened DJFPFP / DJFPVP computer cables
- F46/FEP (+200 °C) & PFA (+260 °C): All-fluoroplastic core insulation and outer sheathing resist sulfuric/hydrochloric acid mist, solvent splash, kiln radiant heat and tropical humidity
- Direct-burial & tray armour (22): Double galvanized steel tape armour on KFF22, KFFP-22, KFFP2-22 and DJFPFP-22 prevents rodent damage and tray crush in smelter/refinery trenches
- Individual + overall DCS screens: DJFPFP pairs individual pair copper braids (or Al/PET foil) with an overall copper braid to stop 4–20 mA / HART / RS-485 pair-to-pair crosstalk
- 300 m EPC production reels: Supplied in 300 m minimum order continuous factory drums with routine 2,500–3,000 V AC test reports in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 450/750 V AC on KFF / KFFP / KFFRP / KFFP2-22 control cables (3000 V AC 5 min test) and 300/500 V AC on DJFPFP computer cables (2000 V AC test) |
| Core and pair range | 2 to 37 cores (0.75 mm2 to 6.0 mm2) on KFF control series; 1 to 24 twisted pairs or triads (0.5 mm2 to 2.5 mm2) on DJFPFP instrumentation series |
| Temperature and material grades | -60 C to +200 C continuous with F46 (FEP) insulation/sheath and tinned copper; -60 C to +260 C with PFA or F46/PFA and silver/nickel-plated copper |
| Screening and armouring options | Unscreened (KFF), copper wire braid (KFFP / KFFRP), copper tape (KFFP2), dual pair+overall braid (DJFPFP) and double steel tape armour (-22) |
| Standard put-up and lead time | 300 m minimum order continuous factory wooden/steel export drums delivered in 7 to 45 working days |
| Minimum bending radius | 6x OD for unarmoured KFF/KFFR, 10x OD for braided/screened KFFP/KFFRP/DJFPFP, and 12x OD for steel-tape armoured KFFP2-22 |
| Flame and acid/solvent resistance | Passes IEC 60332-1-2 and bunched IEC 60332-3 Category A/B/C flame tests; immune to strong acids, alkalis, organic extractants and oils |
KFF, KFFP, KFFRP & Armoured KFFP2-22 450/750 V Control Cable Schedule
| Model & Size (mm²) | Conductor & Screen / Armour | Rated Voltage | Temp. Grade | Nom. OD (mm) | Min. Bend Radius | Approx. Weight (kg/km) | Standard Drum MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| KFF 4x1.5 | Class 1/2 Cu, Unscreened | 450/750 V | 200 / 260 °C | 7.8 | 6x OD | 118 | 300 m drum | Request this size |
| KFF 7x1.5 | Class 1/2 Cu, Unscreened | 450/750 V | 200 / 260 °C | 9.2 | 6x OD | 178 | 300 m drum | Request this size |
| KFF 14x1.5 | Class 1/2 Cu, Unscreened | 450/750 V | 200 / 260 °C | 12.6 | 6x OD | 335 | 300 m drum | Request this size |
| KFFP 4x1.0 | Class 1/2 Cu + Cu Braid | 450/750 V | 200 / 260 °C | 7.9 | 10x OD | 122 | 300 m drum | Request this size |
| KFFP 4x1.5 | Class 1/2 Cu + Cu Braid | 450/750 V | 200 / 260 °C | 8.6 | 10x OD | 152 | 300 m drum | Request this size |
| KFFP 7x1.5 | Class 1/2 Cu + Cu Braid | 450/750 V | 200 / 260 °C | 10.1 | 10x OD | 225 | 300 m drum | Request this size |
| KFFP 10x1.5 | Class 1/2 Cu + Cu Braid | 450/750 V | 200 / 260 °C | 12.4 | 10x OD | 310 | 300 m drum | Request this size |
| KFFP 19x1.5 | Class 1/2 Cu + Cu Braid | 450/750 V | 200 / 260 °C | 15.2 | 10x OD | 515 | 300 m drum | Request this size |
| KFFP 4x2.5 | Class 1/2 Cu + Cu Braid | 450/750 V | 200 / 260 °C | 9.8 | 10x OD | 212 | 300 m drum | Request this size |
| KFFP 4x4.0 | Class 2 Cu + Cu Braid | 450/750 V | 200 / 260 °C | 11.4 | 10x OD | 305 | 300 m drum | Request this size |
| KFFRP 4x1.5 | Class 5 Flex + Cu Braid | 450/750 V | 200 / 260 °C | 9.0 | 10x OD | 162 | 300 m drum | Request this size |
| KFFRP 12x1.5 | Class 5 Flex + Cu Braid | 450/750 V | 200 / 260 °C | 13.6 | 10x OD | 375 | 300 m drum | Request this size |
| KFFP2-22 4x1.5 | Cu Tape + Steel Tape Armour | 450/750 V | 200 °C | 11.8 | 12x OD | 285 | 300 m drum | Request this size |
| KFFP2-22 10x1.5 | Cu Tape + Steel Tape Armour | 450/750 V | 200 °C | 15.8 | 12x OD | 510 | 300 m drum | Request this size |
| KFFP2-22 4x2.5 | Cu Tape + Steel Tape Armour | 450/750 V | 200 °C | 13.0 | 12x OD | 365 | 300 m drum | Request this size |
DJFPFP & DJFPFP-22 300/500 V Dual-Screened DCS Computer Cable Schedule
| Model & Pair Count | Dual Screen & Armour | Conductor Class | Temp. Grade | Nom. OD (mm) | Approx. Weight (kg/km) | Standard Drum MOQ | Next step |
|---|---|---|---|---|---|---|---|
| DJFPFP 1x2x1.0 | Pair Cu Braid + Overall Braid | Class 2 / 5 | 200 / 260 °C | 6.2 | 68 | 300 m drum | Request this size |
| DJFPFP 2x2x1.0 | Pair Cu Braid + Overall Braid | Class 2 / 5 | 200 / 260 °C | 9.6 | 132 | 300 m drum | Request this size |
| DJFPFP 4x2x1.0 | Pair Cu Braid + Overall Braid | Class 2 / 5 | 200 / 260 °C | 11.8 | 225 | 300 m drum | Request this size |
| DJFPFP 8x2x1.0 | Pair Cu Braid + Overall Braid | Class 2 / 5 | 200 / 260 °C | 15.9 | 415 | 300 m drum | Request this size |
| DJFPFP 12x2x1.0 | Pair Cu Braid + Overall Braid | Class 2 / 5 | 200 / 260 °C | 19.2 | 598 | 300 m drum | Request this size |
| DJFPFP 16x2x1.0 | Pair Cu Braid + Overall Braid | Class 2 / 5 | 200 / 260 °C | 21.8 | 780 | 300 m drum | Request this size |
| DJFPFP 4x2x1.5 | Pair Cu Braid + Overall Braid | Class 2 / 5 | 200 / 260 °C | 13.2 | 295 | 300 m drum | Request this size |
| DJFPFP 8x2x1.5 | Pair Cu Braid + Overall Braid | Class 2 / 5 | 200 / 260 °C | 17.8 | 548 | 300 m drum | Request this size |
| DJFPFP-22 4x2x1.0 | Dual Cu Braid + Steel Armour | Class 2 | 200 °C | 15.0 | 390 | 300 m drum | Request this size |
| DJFPFP-22 8x2x1.5 | Dual Cu Braid + Steel Armour | Class 2 | 200 °C | 21.4 | 785 | 300 m drum | Request this size |
ASCII part references for EPC BOMs: TF-KFF-4X15, TF-KFFP-4X15, TF-KFFP-7X15, TF-KFFP-19X15, TF-KFFRP-4X15, TF-KFFP2-22-4X15, TF-DJFPFP-4X2X10, TF-DJFPFP-8X2X15, TF-DJFPFP22-4X2X10.
Also available with PVC outer sheath over fluoroplastic F46 cores (KFVP / KFVRP / DJFPVP, +105 °C outer / +200 °C core) when chemical splash occurs only inside hot junction boxes.
KFF & DJFPFP GB/T 9330, IEC 60228 & IEC 60332-3 Standards
| Standard or specification | Application |
|---|---|
| GB/T 9330 & TICW/06 | Plastic and fluoroplastic insulated 450/750 V control cable construction, 3,000 V AC voltage withstand and core identification rules. |
| IEC 60228 & BS EN 50288-7 | Class 1, Class 2 and Class 5 copper conductor resistance limits and multi-pair instrumentation screening architecture. |
| IEC 60332-1-2 & IEC 60332-3-22 / 24 | Single-cable and bunched vertical tray flame-retardant performance (ZR-KFFP / ZA-DJFPFP). |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and routine 3,000 V AC factory inspection
IEC 60228 — Conductors of insulated cables (Classes 1, 2 and 5)
IEC 60332-3-22 — Tests on electric cables under fire conditions: bunched wires/cables Category A
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
KGG, KGGR, KGGP, KGGRP & KGG22/KGG32 450/750 V Silicone Rubber Control & Armoured Cable
A related cable option for a different application or duty profile.
View productYGC, YGCR, YGCP & YGC22 0.6/1 kV Heavy-Duty Metallurgical Silicone Rubber Power Cable (-60 to +180 °C)
A related cable option for a different application or duty profile.
View productTF-PYRO-SM 0.6/1 kV Slag-Splash Protected Pyrojacketed EAF & Steel-Mill Power/Control Cable (+260 / +1,090 °C)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.