High Temperature Cables TEBAOFLEX

KFF, KFFP, KFFRP, KFFP2-22 & DJFPFP 450/750 V Fluoroplastic Control & Computer Cable

KFF, KFFR, KFFP, KFFRP and steel-tape armoured KFFP2-22 450/750 V fluoroplastic control cables plus DJFPFP / DJFPVP 300/500 V individual-and-overall screened DCS computer cables (TF-KFF-KFFP-DJFPFP) withstand -60 °C to +200 °C (F46/FEP) or +260 °C (PFA) and concentrated acid/alkali mist. Built for overseas metallurgical, nickel-cobalt HPAL, chemical and power-plant EPC projects (2–37 cores & 1–24 pairs, 300 m MOQ).

Product information
SKU
TF-KFF-KFFP-DJFPFP
Brand
TEBAOFLEX
Product overview

KFF, KFFP, KFFRP, armoured KFFP2-22 450/750 V fluoroplastic control cables and DJFPFP 300/500 V individual-and-overall screened computer cables serve heavy industrial EPC projects across -60 °C to +260 °C, spanning 2×0.75 mm² solenoid leads up to 37×1.5 mm² switchgear trunks, 4×6.0 mm² CT circuits and 24x2x1.5 mm² DCS marshalling cables.

In Indonesian HPAL nickel-cobalt acid-leach plants, African copper-cobalt SX-EW solvent-extraction tankhouses, coking/sintering steelworks, chlor-alkali electrolysis halls and coal-chemical boilers, standard KVVP / KVVRP / DJYPVP PVC-sheathed cables embrittle in heat and dissolve in acid/organic mist. Upgrading both insulation and sheath to F46 (FEP, +200 °C) or PFA (+260 °C) delivers a 10x longer maintenance-free service life. Every production drum undergoes 2,500 V to 3,000 V AC 5-minute dielectric immersion testing and spark inspection before export dispatch.

Specify Class 1/2 rigid KFF / KFFP / KFFP2-22 for fixed cable ladders and armoured trench runs, Class 5 flexible KFFR / KFFRP for cabinet doors and vibrating skids, or dual-screened DJFPFP / DJFP2FP2 for low-noise 4–20 mA, HART and Modbus DCS I/O racks (MOQ 300 m per specification, 7 to 45 working days).

Explore the high-temperature wire and cable range for related configurations.

Construction

KFF, KFFP, KFFP2-22 & DJFPFP Cable Construction

Manufactured to GB/T 9330 and TICW/06 industrial fluoroplastic control/instrumentation geometry with IEC 60228 copper conductors and 100 % spark/high-pot testing.

Clean 2D engineering cross-section of KFFP2-22 4-core fluoroplastic control cable showing grey FEP sheath, double steel tape armour, inner bedding, copper braid screen and 4 red/yellow/blue/green cores
KFFP2-22 cross-section: 450/750 V fluoroplastic core insulation, EMC copper braid, inner sheath, steel tape armour and chemical-proof outer jacket.
KFF, KFFP, KFFRP, KFFP2-22 & DJFPFP 450/750 V Fluoroplastic Control & Computer Cable construction
ComponentMaterial and construction
1. Bare, Tinned or Silver/Nickel-Plated Copper ConductorsIEC 60228 Class 1 solid, Class 2 stranded (KFF / KFFP / KFFP2-22) or Class 5 flexible (KFFR / KFFRP / DJFPFPR) copper; tinned up to +200 °C, silver/nickel-plated up to +260 °C.
2. Extruded F46 (FEP) or PFA Core InsulationNumber-coded or colour-coded fluoroplastic wall rated 450/750 V on KFF control series and 300/500 V on DJFPFP twisted-pair computer series.
3. Individual / Overall EMC Screening (P / P2 / P3)Copper wire braid (P >= 80–85 %), copper tape wrap (P2) or aluminium-polyester foil + drain wire (P3); individual pair + overall dual screens on DJFPFP.
4. Fluoroplastic Bedding, Optional Steel Tape Armour (22) & Outer SheathPTFE/fibreglass thermal wrap, extruded F46/PFA inner bedding + double galvanized steel tape armour on -22 models, and acid/flame-proof F46/PFA outer sheath.

KFF / KFFP / KFFP2-22 & DJFPFP Designation Code Guide

  • K / DJ: K = 450/750 V control cable; DJ = 300/500 V electronic computer / DCS twisted-pair cable
  • FF (F46 / PFA): Fluoroplastic core insulation (first F) + fluoroplastic outer sheath (second F), +200 °C or +260 °C
  • R: IEC 60228 Class 5 flexible stranded copper conductor (omit R for Class 1/2 fixed installation)
  • P / P2 / P3: EMC screen: P = copper wire braid, P2 = copper tape, P3 = Al/PET foil (DJFPFP = pair + overall screens)
  • 22: Double galvanized steel tape armour over fluoroplastic inner bedding for crush/trench protection
Applications

KFF & DJFPFP HPAL Nickel, SX-EW Copper & Chemical EPC Duty

Engineered for EPC contractors, design institutes and plant maintenance teams operating corrosive, high-ambient industrial facilities.

Armoured slate-grey KFFP2-22 and DJFPFP fluoroplastic control cables routed on FRP corrosion-resistant ladders into a stainless DCS marshalling cabinet in a chemical/hydrometallurgical plant
High-density KFFP and DJFPFP marshalling trunk entry in an acid-leach hydrometallurgical plant.
  • HPAL nickel-cobalt autoclaves, copper-cobalt SX-EW electrowinning tankhouses, sulfuric acid plants and phosphoric/hydrofluoric chemical units.
  • Blast-furnace tuyere platforms, continuous casting run-out tables, coke-oven gas boosters and cement rotary-kiln preheater towers.
  • Thermal power-plant boiler burner management systems (BMS), sootblower controls, FGD wet-scrubber dampers and ESP precipitator hoppers.
  • Petrochemical DCS / SIS / PLC analog 4–20 mA, HART, Foundation Fieldbus and RS-485 instrumentation marshalling (DJFPFP / DJFP2FP2).

KFF / KFFP2-22 vs DJFPFP vs PAS 5308 Selection Guide

KFF / KFFP / KFFP2-22 vs DJFPFP vs FEP-C-6Y vs PAS 5308 XLPE/PVC
Cable SeriesRated VoltageScreen & Armour ArchitectureTarget Circuit Duty
KFF / KFFP / KFFRP (this page)450/750 VUnscreened or overall Cu braid200–260 °C contactor, valve, damper & CT control circuits
KFFP2-22 / KFF22 (this page)450/750 VCu tape + double steel tape armourDirect-buried trenches, crush zones & smelter pipe racks
DJFPFP / DJFP2FP2 (this page)300/500 VIndividual pair + overall dual screen4–20 mA, HART, thermocouple-to-DCS & RS-485 analog pairs
PAS 5308 / BS 5308300/500 VXLPE/PE + Al/PET foil (+90 °C max)Ambient petrochemical zones below +90 °C without acid mist

For 0.6/1 kV motor power feeders above 6 mm² in the same hot/acidic zone, pair KFFP/DJFPFP with our 0.6/1 kV FEP/PFA GSWB steel-wire-braided power cable.

KFF & DJFPFP Fluoroplastic Control Cable RFQ Checklist

  • Exact model designation (KFF, KFFR, KFFP, KFFRP, KFFP2-22, DJFPFP, DJFPFRP or DJFP2FP2) and flame class (ZA/ZB/ZC).
  • Core count x mm² (for example 7x1.5, 19x1.5) or pair count x 2 x mm² (for example 4x2x1.0, 8x2x1.5).
  • Operating temperature tier: +200 °C (F46/FEP + tinned copper) or +260 °C (PFA + silver/nickel-plated copper).
  • Project drum lengths (MOQ 300 m per item, export fumigated/steel drums, 7 to 45 working days).

Related selection resources

KFF, KFFP, KFFRP & DJFPFP Cable Frequently Asked Questions

What does each letter mean in KFF, KFFP, KFFRP, KFFP2-22 and DJFPFP?

In KFFP2-22: K = control cable (450/750 V), first F = fluoroplastic F46/PFA insulation, second F = fluoroplastic outer sheath, R = Class 5 flexible conductor, P = copper wire braid (P2 = copper tape), and 22 = double steel tape armour. In DJFPFP: DJ = DCS/computer instrumentation cable (300/500 V), F = fluoroplastic insulation, first P = individual pair copper braid, second F = fluoroplastic sheath, and final P = overall screen.

When should I specify DJFPFP instead of KFFP?

Specify DJFPFP (300/500 V twisted pairs with individual + overall screens) for low-level 4–20 mA, HART, pulse and RS-485 DCS signals where pair-to-pair capacitive crosstalk must be blocked; specify KFFP (450/750 V laid-up cores) for 110–230 V AC/DC relay, solenoid, valve and CT circuits.

Why do HPAL nickel-cobalt and SX-EW copper projects specify KFFP and DJFPFP?

Sulfuric acid mist + organic solvent extractants + tropical 55 °C–180 °C vessel heat rapidly crack PVC and swell rubber sheaths, whereas all-fluoroplastic F46/FEP (+200 °C) and PFA (+260 °C) sheaths remain chemically inert and flame-retardant.

Can KFFP2-22 and DJFPFP-22 be installed directly in outdoor trenches or corrosive racks?

Yes — double galvanized steel tape armour (22) sealed beneath an outer F46 fluoroplastic oversheath provides both high radial crush/rodent protection and external acid/alkali corrosion immunity (use stainless steel wire braid SSWB where high tensile pulling or flexing is required).

What is the minimum order quantity and delivery time for KFF and DJFPFP export EPC orders?

300 m per specification is our standard factory production MOQ, supplied on export-ready drums with routine dielectric and conductor resistance test certificates in 7 to 45 working days.

Specifications

KFF / KFFP / KFFP2-22 (450/750 V) & DJFPFP Schedules

KFF & DJFPFP Voltage, Screening, Armour & Drum Summary

  • Complete EPC control & DCS family: Covers unscreened KFF/KFFR, braided KFFP/KFFRP, copper-tape/steel-tape armoured KFFP2-22 and dual-screened DJFPFP / DJFPVP computer cables
  • F46/FEP (+200 °C) & PFA (+260 °C): All-fluoroplastic core insulation and outer sheathing resist sulfuric/hydrochloric acid mist, solvent splash, kiln radiant heat and tropical humidity
  • Direct-burial & tray armour (22): Double galvanized steel tape armour on KFF22, KFFP-22, KFFP2-22 and DJFPFP-22 prevents rodent damage and tray crush in smelter/refinery trenches
  • Individual + overall DCS screens: DJFPFP pairs individual pair copper braids (or Al/PET foil) with an overall copper braid to stop 4–20 mA / HART / RS-485 pair-to-pair crosstalk
  • 300 m EPC production reels: Supplied in 300 m minimum order continuous factory drums with routine 2,500–3,000 V AC test reports in 7 to 45 working days
KFF, KFFP, KFFRP, KFFP2-22 & DJFPFP 450/750 V Fluoroplastic Control & Computer Cable technical data
ParameterValue
Rated voltage450/750 V AC on KFF / KFFP / KFFRP / KFFP2-22 control cables (3000 V AC 5 min test) and 300/500 V AC on DJFPFP computer cables (2000 V AC test)
Core and pair range2 to 37 cores (0.75 mm2 to 6.0 mm2) on KFF control series; 1 to 24 twisted pairs or triads (0.5 mm2 to 2.5 mm2) on DJFPFP instrumentation series
Temperature and material grades-60 C to +200 C continuous with F46 (FEP) insulation/sheath and tinned copper; -60 C to +260 C with PFA or F46/PFA and silver/nickel-plated copper
Screening and armouring optionsUnscreened (KFF), copper wire braid (KFFP / KFFRP), copper tape (KFFP2), dual pair+overall braid (DJFPFP) and double steel tape armour (-22)
Standard put-up and lead time300 m minimum order continuous factory wooden/steel export drums delivered in 7 to 45 working days
Minimum bending radius6x OD for unarmoured KFF/KFFR, 10x OD for braided/screened KFFP/KFFRP/DJFPFP, and 12x OD for steel-tape armoured KFFP2-22
Flame and acid/solvent resistancePasses IEC 60332-1-2 and bunched IEC 60332-3 Category A/B/C flame tests; immune to strong acids, alkalis, organic extractants and oils

KFF, KFFP, KFFRP & Armoured KFFP2-22 450/750 V Control Cable Schedule

KFF, KFFP, KFFRP & Armoured KFFP2-22 450/750 V Fluoroplastic Control Cable — Dimensional & Weight Schedule (200 °C / 260 °C)
Model & Size (mm²)Conductor & Screen / ArmourRated VoltageTemp. GradeNom. OD (mm)Min. Bend RadiusApprox. Weight (kg/km)Standard Drum MOQNext step
KFF 4x1.5Class 1/2 Cu, Unscreened450/750 V200 / 260 °C7.86x OD118300 m drumRequest this size
KFF 7x1.5Class 1/2 Cu, Unscreened450/750 V200 / 260 °C9.26x OD178300 m drumRequest this size
KFF 14x1.5Class 1/2 Cu, Unscreened450/750 V200 / 260 °C12.66x OD335300 m drumRequest this size
KFFP 4x1.0Class 1/2 Cu + Cu Braid450/750 V200 / 260 °C7.910x OD122300 m drumRequest this size
KFFP 4x1.5Class 1/2 Cu + Cu Braid450/750 V200 / 260 °C8.610x OD152300 m drumRequest this size
KFFP 7x1.5Class 1/2 Cu + Cu Braid450/750 V200 / 260 °C10.110x OD225300 m drumRequest this size
KFFP 10x1.5Class 1/2 Cu + Cu Braid450/750 V200 / 260 °C12.410x OD310300 m drumRequest this size
KFFP 19x1.5Class 1/2 Cu + Cu Braid450/750 V200 / 260 °C15.210x OD515300 m drumRequest this size
KFFP 4x2.5Class 1/2 Cu + Cu Braid450/750 V200 / 260 °C9.810x OD212300 m drumRequest this size
KFFP 4x4.0Class 2 Cu + Cu Braid450/750 V200 / 260 °C11.410x OD305300 m drumRequest this size
KFFRP 4x1.5Class 5 Flex + Cu Braid450/750 V200 / 260 °C9.010x OD162300 m drumRequest this size
KFFRP 12x1.5Class 5 Flex + Cu Braid450/750 V200 / 260 °C13.610x OD375300 m drumRequest this size
KFFP2-22 4x1.5Cu Tape + Steel Tape Armour450/750 V200 °C11.812x OD285300 m drumRequest this size
KFFP2-22 10x1.5Cu Tape + Steel Tape Armour450/750 V200 °C15.812x OD510300 m drumRequest this size
KFFP2-22 4x2.5Cu Tape + Steel Tape Armour450/750 V200 °C13.012x OD365300 m drumRequest this size

DJFPFP & DJFPFP-22 300/500 V Dual-Screened DCS Computer Cable Schedule

DJFPFP, DJFPFRP & DJFPFP-22 300/500 V Individual + Overall Screened Fluoroplastic DCS Computer Cable Schedule
Model & Pair CountDual Screen & ArmourConductor ClassTemp. GradeNom. OD (mm)Approx. Weight (kg/km)Standard Drum MOQNext step
DJFPFP 1x2x1.0Pair Cu Braid + Overall BraidClass 2 / 5200 / 260 °C6.268300 m drumRequest this size
DJFPFP 2x2x1.0Pair Cu Braid + Overall BraidClass 2 / 5200 / 260 °C9.6132300 m drumRequest this size
DJFPFP 4x2x1.0Pair Cu Braid + Overall BraidClass 2 / 5200 / 260 °C11.8225300 m drumRequest this size
DJFPFP 8x2x1.0Pair Cu Braid + Overall BraidClass 2 / 5200 / 260 °C15.9415300 m drumRequest this size
DJFPFP 12x2x1.0Pair Cu Braid + Overall BraidClass 2 / 5200 / 260 °C19.2598300 m drumRequest this size
DJFPFP 16x2x1.0Pair Cu Braid + Overall BraidClass 2 / 5200 / 260 °C21.8780300 m drumRequest this size
DJFPFP 4x2x1.5Pair Cu Braid + Overall BraidClass 2 / 5200 / 260 °C13.2295300 m drumRequest this size
DJFPFP 8x2x1.5Pair Cu Braid + Overall BraidClass 2 / 5200 / 260 °C17.8548300 m drumRequest this size
DJFPFP-22 4x2x1.0Dual Cu Braid + Steel ArmourClass 2200 °C15.0390300 m drumRequest this size
DJFPFP-22 8x2x1.5Dual Cu Braid + Steel ArmourClass 2200 °C21.4785300 m drumRequest this size

ASCII part references for EPC BOMs: TF-KFF-4X15, TF-KFFP-4X15, TF-KFFP-7X15, TF-KFFP-19X15, TF-KFFRP-4X15, TF-KFFP2-22-4X15, TF-DJFPFP-4X2X10, TF-DJFPFP-8X2X15, TF-DJFPFP22-4X2X10.

Also available with PVC outer sheath over fluoroplastic F46 cores (KFVP / KFVRP / DJFPVP, +105 °C outer / +200 °C core) when chemical splash occurs only inside hot junction boxes.

Standards

KFF & DJFPFP GB/T 9330, IEC 60228 & IEC 60332-3 Standards

KFF, KFFP, KFFRP, KFFP2-22 & DJFPFP 450/750 V Fluoroplastic Control & Computer Cable standards and test references
Standard or specificationApplication
GB/T 9330 & TICW/06Plastic and fluoroplastic insulated 450/750 V control cable construction, 3,000 V AC voltage withstand and core identification rules.
IEC 60228 & BS EN 50288-7Class 1, Class 2 and Class 5 copper conductor resistance limits and multi-pair instrumentation screening architecture.
IEC 60332-1-2 & IEC 60332-3-22 / 24Single-cable and bunched vertical tray flame-retardant performance (ZR-KFFP / ZA-DJFPFP).

Certifications and document support

TEBAOFLEX ISO 9001 quality management and routine 3,000 V AC factory inspection

IEC 60228 — Conductors of insulated cables (Classes 1, 2 and 5)

IEC 60332-3-22 — Tests on electric cables under fire conditions: bunched wires/cables Category A

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.