YnOGY / YnOGYek / YnOGYekm PVC Mining Cable 0.6/1 kV

Flexible 0.6/1 kV PVC mining cable with Class 5 copper conductors, protective conductors and optional control cores. Choose unscreened YnOGY, semiconductive-screened YnOGYek or individually braid-screened YnOGYekm.

Product information
Brand
TEBAOFLEX
Product overview

YnOGY mining cable is a flexible 0.6/1 kV power cable for stationary and portable mine equipment. Its Class 5 copper conductors have PVC insulation, with an inner PVC sheath and a yellow flame-retardant outer sheath. The YnOGY, YnOGYek and YnOGYekm constructions provide different screening arrangements within the same power, protective and control-circuit selection family.

Select the circuit layout before choosing the conductor size. Unscreened YnOGY is available with four conductors for three-phase power and protection, or with five or seven conductors when one or three control circuits are required. YnOGYek has three individually semiconductive-screened power cores, one bare protective conductor and one insulated control core. YnOGYekm uses individual copper-wire and plastic-thread braid screens, with five- and seven-conductor arrangements.

Choose the screen to match the mine installation. YnOGY serves areas without an explosion hazard. The screened constructions address the specified methane and coal-dust application categories; the equipment protection arrangement and local mine classification remain part of cable selection. Their individual power-core screens have different materials and should be identified explicitly in the enquiry.

The tables retain each model’s complete conductor configuration, maximum diameter and cable weight. They also separate model-specific electrical data. Provide the full model and configuration, route length, installation duty, mine classification and termination details for quotation. Allow a minimum bend radius of 6 times the cable diameter in fixed installation and 10 times the diameter for movable equipment connections.

Explore the mining and tunneling cable range for related configurations.

For armoured underground roadway distribution and screened face-machine feeders, compare these mining cable constructions: Fixed Mining Power Cable — PVC / HEPR, SWA / STA Options (for PVC or 90 °C HEPR-insulated stationary mining power cables with SWA or STA metallic armour); Mine Feeder Type 1 Screened Machine Cable 1.1/1.1 kV (for 1.1/1.1 kV individually screened flexible rubber feeder cables supplying underground coal-face machines). Verify whether the route is a fixed gallery hanger run or a semi-mobile machine supply before ordering.

Construction

Construction

The representative image shows unscreened YnOGY 3 × 6 + 6 mm²: three power cores and one black corrugated protective core arranged compactly around a central filler, with PVC inner and yellow outer sheaths. The screened ek and ekm variants use the separate constructions below.

YnOGY four-core cross-section with three coloured power cores, a black corrugated protective core, central filler and yellow PVC sheath
Representative cable construction.
YnOGY / YnOGYek / YnOGYekm PVC Mining Cable 0.6/1 kV construction
ComponentMaterial and construction
ConductorsFlexible stranded copper, Class 5 to PN-EN 60228.
Core insulationSpecial PVC. Power-core colours: natural, red and blue.
YnOGY protective and control coresBlack corrugated protective core; one control core brown, or three control cores natural, red and blue.
YnOGY core assemblyInsulated conductors laid up around a central filler; no individual electrical screen.
YnOGYek power-core screenSemiconducting compound extruded over each insulated power core.
YnOGYekm power-core screenIndividual braid of copper wire and plastic thread around each power core.
Screened-variant core assemblyScreened power cores and insulated control cores laid up around an uninsulated copper protective conductor.
Inner sheathPVC.
Outer sheathYellow special PVC with increased flame-propagation resistance; oxygen index greater than 29.
Applications

Applications

Use the model-specific screen and conductor layout to supply stationary or portable electrical equipment in underground, open-pit and strip mining installations.

Yellow YnOGY mining cable connecting a closed mine supply enclosure to a portable pump along a supported route
Application illustration.
  • YnOGY: equipment power supply in mine areas without an explosion hazard.
  • YnOGYek and YnOGYekm: screened equipment connections for the specified methane classes a, b and c and coal-dust classes A and B; state the site classification and acceptance requirements with the enquiry.
  • Four-conductor YnOGY layouts for three power circuits and one protective circuit.
  • Five- and seven-conductor layouts where the equipment needs an additional one or three control circuits.
  • Supported fixed routes and movable equipment connections within the stated bend and installation-temperature limits.
  • Coordinate glands, strain relief and the protective-conductor connection with the complete cable configuration.

For underground mine roadway installation practices and gassy-mine power-plus-monitoring cables, review these resources: Armoured and Static Mining Cable: Fixed Distribution Routes (detailing mechanical armour selection, suspension intervals, and fault-loop earthing on fixed underground routes); 1-CBEH 0.6/1kV Gassy Mine Cable with Control and Monitoring Cores (for 0.6/1 kV 1-CBEH gassy-mine cables combining main power conductors with integrated control and earth-monitoring cores). Confirm methane-zone earth-leakage protection, armour earthing continuity, and outer sheath flame retardancy.

Specifications

Specifications

YnOGY / YnOGYek / YnOGYekm PVC Mining Cable 0.6/1 kV technical data
ParameterValue
Rated voltage U₀/U0.6/1 kV.
Test voltagePower cores: 3.2 kV; control cores: 2 kV.
Operating temperature−30°C to +70°C.
Maximum conductor temperature70°C continuous; 160°C during short circuit.
Minimum installation temperature−5°C.
Minimum bend radius6 × D fixed; 10 × D movable; D is the finished cable diameter.
Maximum pulling tension50 × S N when pulled by the conductors or by a cable grip, where S is the total power-conductor cross-sectional area in mm².
Screen selectionYnOGY: unscreened; YnOGYek: individual semiconductive screens; YnOGYekm: individual copper/plastic braid screens.
YnOGY unscreened mining cable configurations
Model and conductor configurationTotal conductorsEach power core (mm²)Protective core (mm²)Each control core (mm²)Max. overall diameter (mm)Calculated weight (kg/km)
YnOGY 3 × 2.5 + 2.5 mm²42.52.5-17.6424
YnOGY 3 × 4 + 4 mm²444-18.6502
YnOGY 3 × 6 + 6 mm²466-21.3616
YnOGY 3 × 10 + 10 mm²41010-24.7800
YnOGY 3 × 16 + 16 mm²41616-28.61377
YnOGY 3 × 25 + 16 mm²42516-35.12050
YnOGY 3 × 35 + 16 mm²43516-38.32500
YnOGY 3 × 50 + 25 mm²45025-44.23435
YnOGY 3 × 70 + 25 mm²47025-49.74487
YnOGY 3 × 95 + 25 mm²49525-56.65780
YnOGY 3 × 120 + 25 mm²412025-60.76900
YnOGY 3 × 2.5 + 2.5 + 2.5 mm²52.52.52.519.0469
YnOGY 3 × 4 + 4 + 4 mm²544420.3588
YnOGY 3 × 6 + 6 + 4 mm²566423.1738
YnOGY 3 × 10 + 10 + 6 mm²51010626.81054
YnOGY 3 × 4 + 4 + 3 × 4 mm²744423.0810
YnOGY 3 × 6 + 6 + 3 × 6 mm²766626.51255
YnOGY 3 × 25 + 16 + 3 × 2.5 mm²725162.539.22780
YnOGY 3 × 35 + 16 + 3 × 2.5 mm²735162.542.73684
YnOGYek screened mining cable configurations
Model and conductor configurationTotal conductorsEach power core (mm²)Protective core (mm²)Each control core (mm²)Max. overall diameter (mm)Calculated weight (kg/km)
YnOGYek 3 × 2.5 + 2.5 + 2.5 mm²52.52.52.520.2535
YnOGYek 3 × 4 + 4 + 4 mm²544421.7660
YnOGYek 3 × 6 + 6 + 4 mm²566424.4850
YnOGYek 3 × 10 + 10 + 6 mm²51010627.71150
YnOGYekm screened mining cable configurations
Model and conductor configurationTotal conductorsEach power core (mm²)Protective core (mm²)Each control core (mm²)Max. overall diameter (mm)Calculated weight (kg/km)
YnOGYekm 3 × 2.5 + 2.5 + 2.5 mm²52.52.52.518.6505
YnOGYekm 3 × 4 + 4 + 4 mm²544420.0619
YnOGYekm 3 × 6 + 6 + 4 mm²566423.6810
YnOGYekm 3 × 10 + 10 + 6 mm²51010625.81110
YnOGYekm 3 × 16 + 16 + 10 mm²516161029.81560
YnOGYekm 3 × 25 + 16 + 16 mm²525161635.62340
YnOGYekm 3 × 16 + 16 + 3 × 1.5 mm²716161.530.31600
YnOGYekm 3 × 25 + 16 + 3 × 2.5 mm²725162.538.12175
YnOGYekm 3 × 35 + 16 + 3 × 2.5 mm²735162.541.12770
YnOGYekm 3 × 50 + 25 + 3 × 4 mm²75025447.53760
YnOGYekm 3 × 70 + 35 + 3 × 4 mm²77035454.15010
YnOGYekm 3 × 95 + 35 + 3 × 4 mm²79535463.06410
YnOGYekm 3 × 120 + 50 + 3 × 4 mm²712050467.58130
YnOGY power-conductor electrical data
Power conductor (mm²)Reactance (Ω/km)Inductance (mH/km)Reference current, AC or DC below 25°C (A)
2.50.1100.3527
40.1010.3237
60.1010.3247
100.0970.3166
160.0940.3087
250.0940.30113
350.0910.29140
500.0910.29172
700.0880.28212
950.0880.28257
1200.0850.27295
YnOGYek power-conductor electrical data
Power conductor (mm²)Reactance (Ω/km)Inductance (mH/km)Conductor-to-screen capacitance (µF/km)Reference current, AC or DC below 25°C (A)
2.50.1240.380.4226
40.1140.360.5534
60.1100.350.5745
100.1040.330.6262
YnOGYekm power-conductor electrical data
Power conductor (mm²)Reactance (Ω/km)Inductance (mH/km)Conductor-to-screen capacitance (µF/km)Reference current, AC or DC below 25°C (A)
2.50.1260.400.4227
40.1130.360.5537
60.1100.350.5747
100.1040.330.6266
160.0960.280.6690
250.0940.280.67115
350.0900.270.76144
500.0880.260.81176
700.0840.250.92213
950.0830.250.96250
1200.0800.241.08290
YnOGY family screen and circuit selection
ModelIndividual power-core screenProtective conductorTotal conductors
YnOGYNoneBlack corrugated insulated copper4, 5 or 7
YnOGYekExtruded semiconducting compoundBare copper5
YnOGYekmCopper-wire and plastic-thread braidBare copper5 or 7

A configuration such as YnOGYek 3 × 10 + 10 + 6 mm² means three 10 mm² power conductors, one 10 mm² protective conductor and one 6 mm² control conductor.

Electrical values belong to the named screen construction. The current table uses AC or DC operation below 25°C; apply route, grouping and thermal corrections for the actual installation.

Maximum diameters and calculated weights are configuration-specific. Check cable entries and handling arrangements against the complete ordering designation.

Select the cable with the mine’s equipment-protection and acceptance requirements; identify the methane and coal-dust class in the enquiry.

Standards

Standards

YnOGY / YnOGYek / YnOGYekm PVC Mining Cable 0.6/1 kV standards and test references
Standard or specificationApplication
PN-EN 60228Class 5 copper-conductor construction reference.
PN-EN 60332-1Single-cable flame-propagation test reference for the PVC sheath construction.
PN-EN 60332-3-24 / IEC 60332-3Category C bunched-cable flame-propagation test reference.

IEC 60228 conductor classes and nominal cross-sectional areas

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.