MINING & TUNNELING CABLES TEBAOFLEX

KGE, KGESh and KGETSh 1.14 to 6kV GOST Mining Cable

Flexible screened rubber trailing cables engineered to GOST 24334 and GOST 31945 at 1.14 kV (1140 V) and 6 kV (6000 V) AC for CIS, Central Asian and Eastern European mining projects. Covers open-pit excavator cable KGE / KGE-KhL (-60 C Arctic option), underground coal-shaft cable KGESh with semi-conducting rubber screens, and heat- and torsion-resistant shearer cable KGETSh (90 C conductor). MOQ 50 m; lead time 7 to 45 working days.

Product information
Brand
TEBAOFLEX
Product overview

Mining operations across Kazakhstan, Uzbekistan, Mongolia, Eastern Europe and CIS-designed mineral projects rely on the GOST screened flexible rubber cable hierarchy—designated KGE (КГЭ), KGE-KhL (КГЭ-ХЛ), KGESh (КГЭШ) and KGETSh (КГЭТШ)—to power 6 kV open-pit electric rope shovels (such as EKG-5A, EKG-8I, EKG-10 and EKG-15) and 1.14 kV underground coal-face shearers, roadheaders and shuttle cars.

Unlike Western cables that use braided metallic phase shields alone, the Russian GOST screened architecture relies on extruded conductive/semi-conducting elastomeric rubber screens (E = Ekranirovannyi) over both the conductor and the EPR/rubber insulation of the three power cores and auxiliary control core, laid around a conductive elastomeric central cradle in underground shaft designs. When a rock fall or mechanical pinch compresses the cable, the semi-conducting phase screen immediately contacts the grounded central cradle or protective earth conductor, tripping the mine fast-acting leakage relay before an open arc can ignite methane or coal dust.

Selecting the correct designation matches the mechanical and thermal environment: KGE (1.14 kV and 6 kV) serves surface excavators and drills down to -40 C (or -60 C in Arctic KGE-KhL execution); KGESh (1.14 kV) features a flame-retardant polychloroprene shaft sheath (Sh = Shakhtnyi) for underground coal faces; and KGETSh (1.14 kV) upgrades to 90 C heat-resistant EPR insulation (T = Teplostoikii) plus synthetic anti-torsion reinforcement for high-output longwall shearers. TEBAOFLEX manufactures this range from a 50 m MOQ with a 7 to 45 working day lead time.

Explore the mining and tunneling cable range for related configurations.

Construction

Construction

The horizontal sample illustrates the GOST 24334 / 31945 screened mining cable architecture (represented by 1.14 kV KGESh / KGETSh and 6 kV KGE), showing three flexible Class 5 copper phase conductors with semi-conducting rubber conductor and insulation screens, one screened auxiliary control core, one grounding conductor, conductive elastomeric central cradle, synthetic reinforcing braid (on KGETSh) and heavy-duty flame-retardant polychloroprene or cold-resistant rubber outer sheath.

Cross-section diagram of GOST KGE and KGESh 1.14 kV to 6 kV screened mining cable showing three screened power cores, control core and protective earth conductor
Representative cable construction.
KGE, KGESh and KGETSh 1.14 to 6kV GOST Mining Cable construction
ComponentMaterial and construction
Power, Control & Earth Conductors (Class 5 Copper)Three flexible stranded copper phase conductors (10 mm2 to 150 mm2), one auxiliary/control conductor (4 mm2 to 10 mm2) and one protective earth conductor (4 mm2 to 50 mm2) per GOST 22483 (IEC 60228 Class 5).
Semi-Conducting Elastomeric Conductor ScreenExtruded conductive rubber layer over each phase conductor equalizing electric field stress and preventing internal ionization.
EPR / Rubber Dielectric (75 C vs 90 C KGETSh)Ozone- and heat-resistant rubber / EPR insulation rated 75 C continuous on standard KGE / KGESh and 90 C continuous on heat-resistant KGETSh.
Semi-Conducting Insulation ScreenExtruded conductive rubber screen over each insulated phase core and auxiliary control core for instantaneous crush/leakage fault detection.
Central Conductive Cradle (KGESh / KGETSh)Profiled semi-conducting rubber central core cradle separating the power and control cores while providing continuous earth-fault contact geometry.
Anti-Torsion Reinforcement & Outer SheathHeavy-duty solar/cold-resistant rubber jacket on KGE (-40 C) and KGE-KhL (-60 C); flame-retardant oil-resistant polychloroprene sheath on KGESh, plus open synthetic anti-torsion braid between double sheaths on KGETSh.
Applications

Applications

Specify KGE, KGE-KhL, KGESh or KGETSh cables for 1.14 kV underground coal machinery and 6 kV open-pit electric excavators designed to GOST electrical standards.

6 kV KGE screened flexible rubber excavator trailing cable feeding an electric rope shovel in a snow-covered open-pit mine
Application illustration.
  • 6 kV open-pit electric rope shovels (EKG-5A, EKG-8I, EKG-10, EKG-12, EKG-15), walking draglines and rotary blasthole drills using KGE or Arctic KGE-KhL (-60 C) trailing cables.
  • 1.14 kV (1140 V) underground coal longwall shearers, roadheaders, loading machines and face conveyors using flame-retardant KGESh or reinforced heat-resistant KGETSh cables.
  • Mobile substation feeders and portable distribution boxes in Central Asian, Mongolian and Eastern European underground and surface mines operating on 1140 V and 6000 V 50 Hz networks.
  • Direct metric GOST replacements where Western AWG-sized SHD-GC (Product 2134) or DIN VDE (N)TSCGEWOU (Product 1956) cables do not match Russian semi-conducting leakage relay impedances or gland diameters.

Related selection resources

Specifications

Specifications

KGE, KGESh and KGETSh 1.14 to 6kV GOST Mining Cable technical data
ParameterValue
Governing standard referenceEngineered to GOST 24334-2020 (underground KGESh / KGETSh) and GOST 31945-2012 (open-pit excavator KGE / KGE-KhL)
Rated AC and DC operating voltages1.14 kV (1140 V AC / 1650 V DC) for KGESh, KGETSh and LV KGE; 6 kV (6000 V AC) for MV excavator KGE and KGE-KhL
Thermal and climatic operating range-40 C to +50 C ambient for KGE; -60 C to +50 C for Arctic KGE-KhL; -30 C to +50 C for underground KGESh and 90 C rated KGETSh
Mechanical tensile and bending limitsMinimum bending radius 5 x cable diameter (1.14 kV) and 6 x cable diameter (6 kV); tensile load up to 19.6 N per mm2 of total copper area
Leakage protection screen resistanceSemi-conducting elastomeric phase and control screens engineered for fast-acting GOST earth-leakage relay tripping upon core crushing
Commercial supply termsMinimum order quantity 50 m; manufacturing lead time 7 to 45 working days with factory high-voltage and screen-resistance test protocols
Variant selection guideChoose 6 kV KGE/KGE-KhL for open-pit excavators; choose 1.14 kV KGESh for standard underground coal machines; choose 1.14 kV KGETSh for high-load 90 C shearers with tensile/torsion reinforcement.
GOST 24334 KGESh, KGETSh & KGE 1.14 kV (1140 V) Screened Mining Cable — Nominal Dimensions & Ampacity
Core Configuration (mm²)Rated VoltageApplicable DesignationsPhase Area (mm²)Earth Area (mm²)Control Area (mm²)Nom. Overall O.D. (mm)Approx. Mass (kg/km)Ampacity KGETSh 90 °C (A)Min. Bend Radius 5xD (mm)
3x10 + 1x4 + 1x41.14 kVKGESh / KGETSh / KGE104427.5104085138
3x16 + 1x6 + 1x61.14 kVKGESh / KGETSh / KGE166631.21420115156
3x25 + 1x10 + 1x61.14 kVKGESh / KGETSh / KGE2510635.81980150179
3x35 + 1x10 + 1x101.14 kVKGESh / KGETSh / KGE35101039.62560185198
3x50 + 1x16 + 1x101.14 kVKGESh / KGETSh / KGE50161044.53380230223
3x70 + 1x25 + 1x101.14 kVKGESh / KGETSh / KGE70251049.84490280249
3x95 + 1x35 + 1x101.14 kVKGESh / KGETSh / KGE95351055.45820340277
3x120 + 1x35 + 1x101.14 kVKGESh / KGETSh / KGE120351060.27080390301
GOST 31945 KGE & KGE-KhL 6 kV (6000 V) Screened Excavator Trailing Cable — Nominal Dimensions & Ampacity
Core Configuration (mm²)Rated VoltageApplicable DesignationsPhase Area (mm²)Earth Area (mm²)Control Area (mm²)Nom. Overall O.D. (mm)Approx. Mass (kg/km)Ampacity at 30 °C Ambient (A)Min. Bend Radius 6xD (mm)
3x16 + 1x6 + 1x106 kVKGE / KGE-KhL1661041.02190120246
3x25 + 1x10 + 1x106 kVKGE / KGE-KhL25101044.82760155269
3x35 + 1x10 + 1x106 kVKGE / KGE-KhL35101048.23390190289
3x50 + 1x16 + 1x106 kVKGE / KGE-KhL50161052.64280235316
3x70 + 1x25 + 1x106 kVKGE / KGE-KhL70251057.85460285347
3x95 + 1x35 + 1x106 kVKGE / KGE-KhL95351063.56890345381
3x120 + 1x35 + 1x106 kVKGE / KGE-KhL120351068.48210395410
3x150 + 1x50 + 1x106 kVKGE / KGE-KhL150501073.89850450443

For 1.14 kV standard KGESh cables with 75 °C rated rubber insulation, multiply the tabulated 90 °C KGETSh current ratings by 0.86; always verify ambient mine airway temperature and reel/handler layering.

Additional multi-control-core configurations (such as 3x25+1x10+3x2.5 mm², 3x50+1x16+3x4 mm² and 3x95+1x25+3x4 mm²) are manufactured to order for shearers requiring multiple pilot and interlock circuits.

Specify climatic execution U (temperate -40 °C), KhL (cold/Arctic -60 °C) or T (tropical mold/humidity resistant) when requesting a quotation.

Standards

Standards

KGE, KGESh and KGETSh 1.14 to 6kV GOST Mining Cable standards and test references
Standard or specificationApplication
GOST 24334-2020Flexible power and control cables for underground and open-pit mining work — General technical specifications (KGESh, KGETSh).
GOST 31945-2012Flexible screened cables with rubber insulation and sheath for mobile machinery and excavators (KGE, KGE-KhL 1.14 kV and 6 kV).
GOST 22483 (IEC 60228)Conductors ofinsulated cables — Class 5 flexible stranded copper conductor resistance and stranding construction.
GOST IEC 60332-1-2Tests on electric and optical fibre cables under fire conditions — Vertical flame propagation test for single insulated wire or cable.

Certifications and document support

TEBAOFLEX company certificates and quality system documentation

IEC Webstore — IEC 60228 Class 5 Conductors and IEC 60332 Flame Testing Standards

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.