(N)TSKCGECWÖU-FN / (N)TSKCGECWOEU-FN 3.6/6 kV Underground Mining Monitored MV Festoon Cable
(N)TSKCGECWÖU-FN ((N)TSKCGECWOEU-FN) is a 3.6/6 kV flexible medium-voltage rubber cable built with reference to DIN VDE 0250-813 for underground monorail and roadway festoon systems, combining three class 5 tinned-copper EPR phase cores (35 to 120 mm²), three double-concentric control/earth elements in the interstices, and a vulcanized galvanized-steel plus tinned-copper 6ÜL KON monitoring screen under a red 5GM5 rubber outer sheath.
(N)TSKCGECWÖU-FN / (N)TSKCGECWOEU-FN underground mining festoon cable delivers 3.6/6 kV power (Umax 4.2/7.2 kV AC) along roof-suspended monorail loops for longwall energy trains, gate-road transformer advances and mobile heading substations, integrating three semiconductive-screened EPR phase cores (35 to 120 mm²), three double-concentric 1.5ST KON + PE KON interstitial units and a bonded 6ÜL KON steel/copper monitoring screen inside a red 5GM5 sheath.
Standard open-pit trailing cables lack the concentric pilot and overall crush-monitoring architecture demanded by underground mine safety relays, whereas longwall cutter-chain cables (NTSKCGECWOEU without the -FN festoon lay) are stiffened for energy-chain troughs rather than repeated tight saddle loops on overhead I-beams. In (N)TSKCGECWÖU-FN, TEBAOFLEX builds each interstitial unit around a flexible support core: an inner spiral of tinned copper wires forms the 1.5 mm² control pilot, an EPR wall isolates it, and a second concentric tinned-copper spiral forms one-third of the protective earth. Between the GM1b inner sheath and the red 5GM5 outer sheath, mixed galvanized-steel and tinned-copper wires are vulcanized directly into the elastomer matrix so roof-fall impact or trolley pinch trips the monitoring relay immediately without allowing sheath creep in the festoon loops.
Select (N)TSKCGECWÖU-FN for 3.6/6 kV suspended monorail and festoon loops in underground coal, potash and hard-rock mines. Where cables run inside armoured face conveyor chains choose NTSKCGECWOEU coal-cutter chain cable, for monitored roadway feeders choose NTSCGECCWOEU, and for open-pit shovel ground dragging choose grid-reinforced NTSCGEWÖU-TR.
Explore the mining and tunneling cable range for related configurations.
(N)TSKCGECWÖU-FN Monitored Festoon Cable Construction
(N)TSKCGECWÖU-FN is manufactured on TEBAOFLEX triple-extrusion and heavy-rubber vulcanization lines with reference to DIN VDE 0250-813.

| Component | Material and construction |
|---|---|
| 1. Phase conductors | Finely stranded tinned annealed copper wires, class 5 with reference to DIN VDE 0295 / IEC 60228 (35 to 120 mm²). |
| 2. Dielectric and field control | Inner semiconductive rubber stress-control layer, EPR insulation compound to DIN VDE 0207-20, and outer black semiconductive elastomer layer printed 1, 2, 3. |
| 3. Double-concentric KON units | Three outer-interstice units: concentric tinned-copper control wires (1.5ST KON) over a support core, EPR insulation, and concentric tinned-copper protective earth wires (25/3 to 70/3 KON). |
| 4. Inner sheath | Elastomeric inner covering compound type GM1b to DIN VDE 0207-21 filling the laid-up core geometry. |
| 5. 6ÜL KON monitoring armour-screen | Spirally applied galvanized steel wires and tinned copper wires bonded in a vulcanized layer between the inner and outer sheaths. |
| 6. Outer sheath | Heavy-duty flame-retardant and oil-resistant rubber compound type 5GM5 to DIN VDE 0207-21, red colour (LOI above 29), inkjet marked. |
(N)TSKCGECWÖU-FN Designation Breakdown
- (N)TS: Heavy flexible medium-voltage mining cable built with reference to DIN VDE 0250-813
- KC: Double-concentric control and protective earth conductors (1.5ST KON + PE KON) in the outer interstices
- GE: EPR core insulation with inner and outer semiconductive rubber field-control layers
- CW: Vulcanized overall monitoring screen (6ÜL KON) of galvanized steel and tinned copper wires
- ÖU-FN: Oil-resistant, flame-retardant red 5GM5 outer sheath engineered for underground festoon (-FN) loops
(N)TSKCGECWÖU-FN Underground Monorail Festoon Applications
(N)TSKCGECWÖU-FN is engineered specifically for suspended medium-voltage festoon loops in underground mines.

- Overhead monorail energy trains (pantechnicons) feeding 3.6/6 kV longwall face switchgear from gate-road substations.
- Roof-suspended I-beam and C-rail festoon systems advancing behind roadheaders and continuous miners.
- Underground potash, salt, copper and coal mine galleries requiring pilot earth-continuity plus outer-sheath crush monitoring.
- Damp, wet and oil-mist underground roadways operating at -25 °C to +80 °C flexible ambient (-40 °C to +90 °C fixed).
(N)TSKCGECWÖU-FN vs Chain and Trailing Mining Cables
| Cable designation | Primary mining duty | Pilot and monitoring design | Outer sheath |
|---|---|---|---|
| (N)TSKCGECWÖU-FN (this page) | Underground overhead monorail festoons (3.6/6 kV) | 3 double-concentric KON + 6ÜL KON steel/Cu screen | Red 5GM5 rubber |
| NTSKCGECWOEU chain cable | Longwall shearer handler chains (1.8/3–3.6/6 kV) | Pilot/earth + overall screen tuned for drag chains | Red or yellow 5GM5 |
| (N)TSKCGEWÖU | Underground mobile trailing and reeling (3.6/6 kV) | Aux/pilot cores without outer steel/Cu 6ÜL armour-screen | Red or black 5GM5 |
| NTSCGEWÖU-TR | Open-pit shovel and dragline ground trailing (3.6/6–18/30 kV) | 3 split earth cores + reinforcing anti-tear grid tape | Black tear-resistant 5GM5 |
ASCII search equivalents: (N)TSKCGECWOEU-FN 3x50; NTSKCGECWOEU-FN 3x70; (N)TSKCGECWÖU-FN 3.6/6 kV; 3x95+3x(1.5ST KON+50/3KON)+6ÜL KON.
(N)TSKCGECWÖU-FN Mining Festoon RFQ Checklist
- Exact size code from 3x35 to 3x120 mm² (or custom phase/pilot ratio if required by the mine relay).
- Monorail trolley saddle radius, loop depth, travel stroke and ambient roadway temperature.
- Mine pilot-monitoring relay impedance and diode/termination scheme on the 1.5ST KON and 6ÜL KON circuits.
- Required continuous piece length per drum and underground shaft cage / drift clearance limits on drum flange diameter.
- Target delivery schedule and total meterage (MOQ 50 m; lead time 7 to 45 working days).
Related selection resources
- Mining and tunneling cable catalog
- Mining and tunneling cable solutions by equipment
- Engineering guide: medium-voltage mining cable selection (3.3 to 35 kV)
- NTSKCGECWOEU 1.8/3–3.6/6 kV longwall coal-cutter chain cable
- (N)TSKCGEWÖU 3.6/6 kV underground mining trailing cable
- NTSCGECCWOEU 3.6/6–6/10 kV armoured monitored mining cable
- Engineering guide: 8-step mining cable selection for mobile equipment
(N)TSKCGECWÖU-FN Mining Festoon Cable FAQ
What does the -FN suffix mean in (N)TSKCGECWÖU-FN?
1 dedicated underground festoon construction (-FN) in which lay lengths, double-concentric KON interstitial units and a vulcanized 6ÜL KON steel/copper monitoring layer are balanced for overhead monorail trolley loops.
How are the 1.5ST KON and PE KON elements arranged in (N)TSKCGECWÖU-FN?
3 double-concentric elements sit in the outer phase interstices: each has tinned-copper 1.5 mm² control wires over a support core, an EPR wall, and concentric tinned-copper protective earth wires.
What is the 6ÜL KON layer between the sheaths of (N)TSKCGECWÖU-FN?
1 spiral monitoring screen combining galvanized steel wires and tinned copper wires vulcanized between the GM1b inner sheath and red 5GM5 outer sheath to detect crush or penetration faults.
What outer diameter and ampacity does (N)TSKCGECWÖU-FN 3x70 mm² have?
56 mm nominal outer diameter (±2.5 mm), 250 A current rating at 30 °C in air, 5,410 kg/km approximate weight and 3,150 N maximum phase tensile pull.
What are the MOQ and lead time for (N)TSKCGECWÖU-FN?
50 m minimum order quantity with a factory production lead time of 7 to 45 working days.
(N)TSKCGECWÖU-FN 3.6/6 kV Technical Data and Size Schedule
(N)TSKCGECWÖU-FN Key Electrical and Mechanical Ratings
- Double-concentric interstices: Three interstitial elements each combine a concentric 1.5 mm² ST KON control layer under EPR and a concentric KON protective earth layer
- 6ÜL KON monitoring screen: Spirally applied galvanized steel and tinned copper wires vulcanized between the GM1b inner and red 5GM5 outer sheaths
- 3.6/6 kV MV rating: Permissible up to 4.2/7.2 kV AC (5.4/10.8 kV DC) with 11 kV AC factory test voltage
- Underground festoon duty: Optimised core lay for monorail and roof-beam festoon loops at -25 °C to +80 °C flexible ambient and LOI above 29
- Project manufacturing: 3x35 to 3x120 mm² builds produced from MOQ 50 m in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 3.6/6 kV U0/U (max. operating 4.2/7.2 kV AC, 5.4/10.8 kV DC; 11 kV AC test) |
| Phase size range | 3x35 mm² to 3x120 mm² class 5 tinned copper with 3 double-concentric KON units |
| Monitoring architecture | Three 1.5ST KON + PE/3 KON interstitial units plus 6ÜL KON steel-copper overall screen |
| Insulation and sheath | Semiconductive-screened EPR phases, GM1b inner sheath, red 5GM5 outer rubber sheath |
| Operating temperature | -25 °C to +80 °C flexible festoon duty (-40 °C to +90 °C fixed); 90 °C conductor max |
| Mechanical limits | 15 N/mm² max phase tensile load (1,575 to 5,400 N); bend radius to DIN VDE 0298-3 |
| Supply terms | MOQ 50 m; manufacturing lead time 7 to 45 working days |
(N)TSKCGECWÖU-FN 3.6/6 kV Size and Electrical Schedule
| Model and core designation | Nominal OD (mm) | Max. DC resistance at 20 °C (Ω/km) | Current at 30 °C (A) | 1 s short-circuit (kA) | Approx. weight (kg/km) | Max. tensile load (N) | Next step |
|---|---|---|---|---|---|---|---|
| (N)TSKCGECWOEU-FN 3x35+3x(1.5ST KON+25/3KON)+6UL KON | 47 | 0.554 | 162 | 4.3 | 3,494 | 1,575 | Request this size |
| (N)TSKCGECWOEU-FN 3x50+3x(1.5ST KON+25/3KON)+6UL KON | 52 | 0.386 | 202 | 6.1 | 4,339 | 2,250 | Request this size |
| (N)TSKCGECWOEU-FN 3x70+3x(1.5ST KON+35/3KON)+6UL KON | 56 | 0.272 | 250 | 8.5 | 5,410 | 3,150 | Request this size |
| (N)TSKCGECWOEU-FN 3x95+3x(1.5ST KON+50/3KON)+6UL KON | 59 | 0.206 | 301 | 11.6 | 6,281 | 4,275 | Request this size |
| (N)TSKCGECWOEU-FN 3x120+3x(1.5ST KON+70/3KON)+6UL KON | 68 | 0.164 | 352 | 14.6 | 8,353 | 5,400 | Request this size |
Nominal outer diameter tolerance is ±2.5 mm; inductance spans 0.30 to 0.26 mH/km and operating capacitance 0.28 to 0.46 µF/km across 35 to 120 mm².
Current-carrying capacities apply at 30 °C ambient in air with derating factors to DIN VDE 0298-4; maximum tensile pull equals 15 N/mm² across the three phase conductors.
ASCII part references: (N)TSKCGECWOEU-FN 3x35; (N)TSKCGECWOEU-FN 3x50; NTSKCGECWOEU-FN 3x70; (N)TSKCGECWOEU-FN 3x95; (N)TSKCGECWOEU-FN 3x120 3.6/6 kV.
(N)TSKCGECWÖU-FN Standards and Test References
| Standard or specification | Application |
|---|---|
| DIN VDE 0250-813 (reference) | Design and 11 kV AC voltage test basis for medium-voltage flexible mining cables. |
| DIN VDE 0295 / IEC 60228 | Class 5 finely stranded tinned copper phase conductors. |
| DIN VDE 0207-20 / 0207-21 | EPR insulation, GM1b inner sheath and heavy-duty 5GM5 outer sheath compounds. |
| DIN EN / IEC 60332-1-2 | Vertical flame propagation test on single insulated cable (sheath oxygen index above 29). |
| DIN EN / IEC 60811-404 | Mineral oil immersion resistance of the red 5GM5 elastomer outer sheath. |
| DIN VDE 0298-3 / 0298-4 | Minimum festoon bending radii and current-carrying capacity derating rules. |
Certifications and document support
TEBAOFLEX ISO quality assurance and routine factory test reports
DIN Media — DIN VDE 0250-813 / 0298-3 / 0298-4 standards reference
IEC Webstore — IEC 60228 conductor, IEC 60332 flame and IEC 60811 oil test references
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
NTSKCGECWOEU 1.8/3–3.6/6 kV Coal Cutter Chain Cable
A related cable option for a different application or duty profile.
View product(N)TSKCGEWÖU 3.6/6kV Medium Voltage Mining Trailing Cable
For 3.6/6 kV trailing duty behind mobile mining equipment.
View productNTSCGECCWOEU Armoured Monitored Mining Cable 3.6/6-6/10kV
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.