OnG, OnGc-G, OGc (0.6/1 & 3.6/6 kV) & 8GTL3Gkon-G Flexible Rubber Underground & Open-Pit Mining Cable
OnG (0.6/1 kV), heat-resistant OnGc-G (0.6/1 kV, 90 °C IEP EPR + ON4 yellow rubber), medium-voltage OGc (3.6/6 kV, 12 kV test, red rubber) and 8GTL3Gkon-G (300/500 V paired control) are Class 5 tinned-copper flexible elastomer cables for underground and open-pit mining machinery where unscreened power feeders or monitored paired control lines are specified.
OnG (0.6/1 kV), OnGc-G (0.6/1 kV, 90 °C), OGc (3.6/6 kV) and 8GTL3Gkon-G (300/500 V) complete the Polish PN-G / WT flexible rubber trailing and mobile equipment cable series alongside screened OnGcekż-G, serving underground auxiliary drives, movable quarry switchgear, open-pit belt-conveyor shiftable stations and excavator control loops.
Not every mobile or semi-mobile mine feeder uses elastomeric conductive phase screens: auxiliary pumps, portable fans, drill-rig distribution boxes and open-pit 6 kV skid feeders often specify unscreened symmetrical split-earth constructions for simpler field termination and compact outer diameter. OnGc-G pairs EN 60228 Class 5 tinned copper with 90 °C IEP ethylene-propylene rubber (EPR), three interstitial green-yellow earth cores (e.g. 3×50+3×25/3 mm², 233 A) and a tear-resistant yellow ON4 chloroprene sheath; OnG covers general 1×16–1×185 and 2–5 core 0.6/1 kV leads; OGc steps up to 3.6/6 kV (12 kV AC test) with semiconductive field control and a red flame-retardant rubber sheath; and 8GTL3Gkon-G provides 3 to 20 EPR twisted pairs under a tinned-copper kon monitoring braid for open-pit automation.
Where gassy underground coal faces mandate individual or collective elastomeric/copper screens with pilot cores, select OnGcekż-G, OnGcekżi-G or OnGcekż-GW instead.
Explore the mining and tunneling cable range for related configurations.
OnG, OnGc-G, OGc & 8GTL3Gkon-G Rubber Cable Construction
All four designations use finely stranded Class 5 tinned annealed copper conductors and heavy-duty oil- and flame-resistant ON3 / ON4 mining elastomers.

| Component | Material and construction |
|---|---|
| 1. Flexible tinned copper conductors | Multi-stranded tinned annealed copper, Class 5 to EN / IEC 60228, resisting sulphide tarnishing and moist mine atmospheres. |
| 2. Elastomer core insulation | OnG: 60 °C IE1 rubber; OnGc-G & 8GTL3Gkon-G: 90 °C IEP EPR rubber; OGc 3.6/6 kV: inner semiconductive layer + 90 °C EPR + outer semiconductive layer. |
| 3. Symmetrical split earths / pairs | OnGc-G & OGc place three split protective-earth conductors symmetrically in the phase interstices; 8GTL3Gkon-G twists 1.0 mm² pairs inside an inner rubber sheath and tinned-copper kon braid. |
| 4. Inner sheath (double-sheath builds) | Extruded rubber inner bedding stabilizing core geometry on OnGc-G, OGc and 8GTL3Gkon-G. |
| 5. Heavy-duty ON3 / ON4 outer sheath | Oil-resistant, flame-retardant rubber (LOI > 29, EN 60332-1-2): yellow on OnGc-G 0.6/1 kV, red on OGc 3.6/6 kV, black/yellow on OnG and 8GTL3Gkon-G. |
OnG / OnGc-G / OGc / 8GTL3Gkon-G Designation Breakdown
- O / On: Mobile rubber cable; 'n' denotes oil-resistant, flame-retardant chloroprene outer sheath (LOI > 29)
- G: Mining construction with Class 5 tinned copper conductors; suffix '-G' marks underground mine approval geometry
- c: Heat-resistant 90 °C ethylene-propylene rubber (IEP / EPR) core insulation (OnGc-G and 3.6/6 kV OGc)
- 3xS+3xs/3: Three main phase cores plus a split protective-earth cross-section divided equally into three interstices
- 8GTL3Gkon-G: 300/500 V EPR-insulated twisted-pair open-pit control cable with tinned-copper kon monitoring braid
OnG, OnGc-G & OGc Underground and Open-Pit Mining Applications
Matched to underground auxiliary machinery, quarries and open-pit lignite / copper / aggregate mines.

- Underground 0.6/1 kV auxiliary pumps, portable ventilation fans, grout mixers and mobile distribution skids (OnG and 90 °C OnGc-G).
- Open-pit mine and quarry 3.6/6 kV movable transformer skids, crushers and shiftable conveyor drive stations (OGc).
- Open-pit excavator, spreader and belt-conveyor monitored control, telemetry and safety-interlock loops (8GTL3Gkon-G 300/500 V).
OnGc-G & OGc vs Screened OnGcekż-G and (N)TSCGEWÖU-TR
| Mining rubber cable | Rated U0/U | Screening & pilots | Primary mining duty |
|---|---|---|---|
| OnGc-G / OnG (this page) | 0.6/1 kV | Unscreened; 3 split earths on OnGc-G | Auxiliary underground & quarry 0.6/1 kV mobile loads |
| OGc (this page) | 3.6/6 kV | MV semicond. layers + 3 split earths | Open-pit & quarry 6 kV movable skids and conveyors |
| OnGcekż-G / OnGcekżi-G | 0.6/1 & 3.6/6 kV | Conductive/Cu screens + pilot core | Gassy underground coal-face shearers & roadheaders |
| (N)TSCGEWÖU-TR | 3.6/6 to 18/30 kV | VDE 0250-813 MV trailing construction | Heavy open-pit electric rope shovels & draglines |
Quick distinction: the suffix 'ekż' in Polish mining cables adds elastomeric/copper phase screens plus an auxiliary pilot core; OnG, OnGc-G and OGc omit those screens for simpler auxiliary and open-pit feeders.
OnG, OnGc-G, OGc & 8GTL3Gkon-G RFQ Checklist
- Exact designation: OnG (0.6/1 kV), OnGc-G (0.6/1 kV 90 °C), OGc (3.6/6 kV) or 8GTL3Gkon-G (300/500 V pairs).
- Cross-section or pair count (e.g. OnGc-G 3x50+3x25/3, OGc 3x70+3x16, or 8GTL3Gkon-G 10x2x1.0).
- Underground vs open-pit UV exposure and preferred sheath colour (yellow LV, red MV, or black open-pit).
- Cable gland entry diameter range and drum cut lengths.
- Total meterage and delivery schedule (MOQ 50 m; 7 to 45 working days).
Related selection resources
- Mining and tunneling cable catalog
- Mining and tunneling cable solutions by equipment
- Engineering guide: 0.6/1 kV mining cable selection for mobile equipment
- Engineering guide: 8-step mining cable selection for mobile equipment
- OnGcekż-G screened flexible rubber coal-face trailing cable
- OnGcekż-G2 0.6/1 kV compact single-sheath screened mining cable
- OnGcekżi-G 0.6/1 kV individually copper-screened mining cable
- OnGcekż-GW & O2nGcekż-GW braid-reinforced mining trailing cable
OnG, OnGc-G, OGc & 8GTL3Gkon-G Mining Cable FAQ
How does OnGc-G differ from standard OnG at 0.6/1 kV?
90 °C vs 60 °C thermal rating and earthing layout: OnGc-G uses 90 °C IEP EPR insulation, three symmetrical split earths (e.g. 3x50+3x25/3) and an ON4 yellow double sheath, whereas OnG uses 60 °C IE1 rubber in single- or standard multi-core layouts.
Should I choose OnGcekż-G instead of OnGc-G or OnG/OGc on gassy coal faces?
Yes. Whenever underground coal or methane regulations require screened power cores and a pilot earth-monitoring conductor, choose OnGcekż-G; OnGc-G and OGc are unscreened split-earth feeders.
How does 8GTL3Gkon-G pair with OnG and OnGc-G in open-pit mines?
300/500 V twisted-pair control, telemetry and safety-interlock wiring (3x2x1.0 to 20x2x1.0 mm²) protected by 90 °C EPR insulation, a tinned-copper kon monitoring braid and an ON3 rubber jacket.
What test voltage applies to 3.6/6 kV OnG/OGc cables?
12,000 V (12 kV) 50 Hz AC factory dielectric testing across the semiconductive-screened 90 °C EPR phase insulation.
What are the MOQ and manufacturing lead time for OnG, OnGc-G and OGc?
50 m minimum order quantity with a production lead time of 7 to 45 working days.
OnG, OnGc-G, OGc & 8GTL3Gkon-G Technical Data and Schedule
OnG, OnGc-G & OGc Key Voltage, Ampacity and Bend Ratings
- OnGc-G 0.6/1 kV (90 °C): Class 5 tinned Cu, 90 °C IEP EPR, symmetrical 3+3 split earths (3x6+3x6/3 to 3x120+3x35/3) and safety-yellow ON4 rubber
- OnG 0.6/1 kV utility: Single-core (1x16 to 1x185) and multi-core (2x2.5 to 5x16 mm²) Class 5 tinned Cu in flame-retardant ON3 chloroprene
- OGc 3.6/6 kV open-pit MV: Semiconductive-controlled 90 °C EPR with 3 interstitial earths (3x16+3x6 to 3x95+3x16), tested at 12 kV AC in red rubber
- 8GTL3Gkon-G 300/500 V: 3x2x1.0 to 20x2x1.0 EPR twisted-pair open-pit control cable with tinned-copper kon monitoring screen
- Flame & cold resilience: Self-extinguishing LOI > 29 elastomer jackets (EN 60332-1-2) rated down to -40 °C; MOQ 50 m in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | OnG and OnGc-G: 0.6/1 kV (3 kV AC test); OGc: 3.6/6 kV (12 kV AC test); 8GTL3Gkon-G: 300/500 V (2 kV test) |
| Conductor and core range | Class 5 tinned Cu: OnG 1x16-1x185 and 2x2.5-5x16; OnGc-G 3x6+3x6/3-3x120+3x35/3; OGc 3x16+3x6-3x95+3x16 |
| Operating temperature | -40 °C to +70 °C ambient; max conductor 90 °C on OnGc-G, OGc and 8GTL3Gkon-G (250 °C fault), 60 °C on OnG |
| Sheath compound and colour | ON3 / ON4 oil-resistant flame-retardant rubber (LOI above 29): yellow 0.6/1 kV OnGc-G, red 3.6/6 kV OGc |
| Minimum bend radius | 6 x OD fixed / 10 x OD mobile on OnG, OnGc-G and 8GTL3Gkon-G; 10 to 12 x OD on 3.6/6 kV OGc |
| Supply terms | MOQ 50 m; manufacturing lead time 7 to 45 working days |
OnG & OnGc-G (0.6/1 kV), OGc (3.6/6 kV) & 8GTL3Gkon-G (300/500 V) Schedule
| Type and cross-section | Rated U0/U | Insulation / sheath system | Approx. OD (mm) | Current 25 °C air (A) | Approx. weight (kg/km) | Next step |
|---|---|---|---|---|---|---|
| OnG 1x25 | 0.6/1 kV | 60 °C IE1 / ON3 rubber | 16.5 | — | 498 | Request this size |
| OnG 1x50 | 0.6/1 kV | 60 °C IE1 / ON3 rubber | 20.1 | — | 789 | Request this size |
| OnG 1x95 | 0.6/1 kV | 60 °C IE1 / ON3 rubber | 25.0 | — | 1,348 | Request this size |
| OnG 1x185 | 0.6/1 kV | 60 °C IE1 / ON3 rubber | 31.4 | — | 2,325 | Request this size |
| OnG 3x4+4 | 0.6/1 kV | 60 °C IE1 / ON3 rubber | 21.4 | — | 534 | Request this size |
| OnG 3x10+10 | 0.6/1 kV | 60 °C IE1 / ON3 rubber | 28.4 | — | 1,011 | Request this size |
| OnG 3x16+10 | 0.6/1 kV | 60 °C IE1 / ON3 rubber | 33.4 | — | 1,400 | Request this size |
| OnGc-G 3x16+3x10/3 | 0.6/1 kV | 90 °C IEP EPR / yellow ON4 | 24.9 | 118 | 1,095 | Request this size |
| OnGc-G 3x25+3x16/3 | 0.6/1 kV | 90 °C IEP EPR / yellow ON4 | 28.3 | 152 | 1,557 | Request this size |
| OnGc-G 3x35+3x16/3 | 0.6/1 kV | 90 °C IEP EPR / yellow ON4 | 31.8 | 187 | 1,952 | Request this size |
| OnGc-G 3x50+3x25/3 | 0.6/1 kV | 90 °C IEP EPR / yellow ON4 | 36.7 | 233 | 2,660 | Request this size |
| OnGc-G 3x70+3x25/3 | 0.6/1 kV | 90 °C IEP EPR / yellow ON4 | 40.8 | 288 | 3,493 | Request this size |
| OnGc-G 3x95+3x35/3 | 0.6/1 kV | 90 °C IEP EPR / yellow ON4 | 46.8 | 345 | 4,594 | Request this size |
| OnGc-G 3x120+3x35/3 | 0.6/1 kV | 90 °C IEP EPR / yellow ON4 | 50.2 | 400 | 5,474 | Request this size |
| OnG/OGc 3x16+3x6 | 3.6/6 kV | 90 °C EPR + semicond. / red rubber | 50.0 | 111 | 2,600 | Request this size |
| OnG/OGc 3x25+3x6 | 3.6/6 kV | 90 °C EPR + semicond. / red rubber | 54.9 | 143 | 3,100 | Request this size |
| OnG/OGc 3x35+3x6 | 3.6/6 kV | 90 °C EPR + semicond. / red rubber | 60.2 | 175 | 3,900 | Request this size |
| OnG/OGc 3x50+3x10 | 3.6/6 kV | 90 °C EPR + semicond. / red rubber | 63.5 | 215 | 4,700 | Request this size |
| OnG/OGc 3x70+3x16 | 3.6/6 kV | 90 °C EPR + semicond. / red rubber | 69.0 | 265 | 5,800 | Request this size |
| OnG/OGc 3x95+3x16 | 3.6/6 kV | 90 °C EPR + semicond. / red rubber | 72.1 | 317 | 6,750 | Request this size |
| OnG/8GTL3Gkon-G 5x2x1.0 | 300/500 V | EPR pairs + tinned Cu kon / ON3 | 16.2 | — | 338 | Request this size |
| OnG/8GTL3Gkon-G 10x2x1.0 | 300/500 V | EPR pairs + tinned Cu kon / ON3 | 20.3 | — | 525 | Request this size |
| OnG/8GTL3Gkon-G 20x2x1.0 | 300/500 V | EPR pairs + tinned Cu kon / ON3 | 25.9 | — | 849 | Request this size |
Additional OnG multi-core sizes (2x2.5 to 2x16, 3x2.5+2.5, 3x6+6, 4x2.5 to 4x25, 5x2.5 to 5x16 mm²), OnGc-G 3x6+3x6/3 & 3x10+3x10/3, and 8GTL3Gkon-G 3, 4, 7, 12, 14 & 16-pair builds are supplied to order.
For screened longwall shearer, roadheader and gassy coal-face feeders with pilot cores, specify OnGcekż-G, OnGcekżi-G, OnGcekż-G2 or OnGcekż-GW.
ASCII part references: OnG 1x95 0.6/1 kV; OnGc-G 3x50+3x25/3 0.6/1 kV; OGc 3x70+3x16 3.6/6 kV; 8GTL3Gkon-G 10x2x1.0 300/500 V.
OnG, OnGc-G & OGc Elastomer Flame and Oil Standards
| Standard or specification | Application |
|---|---|
| EN / IEC 60228 | Class 5 finely stranded tinned annealed copper conductors. |
| PN-G-90100 / WT Mining Elastomer Practice | IE1 / IEP EPR insulation and ON3 / ON4 tear- and oil-resistant mining rubber sheaths. |
| EN / IEC 60332-1-2 & IEC 60811-404 | Flame-retardant (LOI > 29) and mineral-oil-resistant elastomer verification. |
Certifications and document support
TEBAOFLEX ISO quality assurance and routine factory test reports
IEC Webstore — IEC 60228, IEC 60502, IEC 60332 and IEC 60793 standards references
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
OnGcekż-G2 0.6/1 kV Single-Sheath Longwall & Heading Mining Trailing Cable
A related cable option for a different application or duty profile.
View productOnGcekżi-G 0.6/1 kV Individually Screened Intrinsically Safe & Control Mining Cable
A related cable option for a different application or duty profile.
View productOnGcekż-GW, O2nGcekż-G, O2nGcekż-GW & OnGcrekgż-G(S) (0.6/1–18/30 kV) Reinforced & Water-Blocked Mining Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.