MINING & TUNNELING CABLES TEBAOFLEX

OnG, OnGc-G, OGc (0.6/1 & 3.6/6 kV) & 8GTL3Gkon-G Flexible Rubber Underground & Open-Pit Mining Cable

OnG (0.6/1 kV), heat-resistant OnGc-G (0.6/1 kV, 90 °C IEP EPR + ON4 yellow rubber), medium-voltage OGc (3.6/6 kV, 12 kV test, red rubber) and 8GTL3Gkon-G (300/500 V paired control) are Class 5 tinned-copper flexible elastomer cables for underground and open-pit mining machinery where unscreened power feeders or monitored paired control lines are specified.

Product information
SKU
TF-ONG-ONGC-OGC
Brand
TEBAOFLEX
Product overview

OnG (0.6/1 kV), OnGc-G (0.6/1 kV, 90 °C), OGc (3.6/6 kV) and 8GTL3Gkon-G (300/500 V) complete the Polish PN-G / WT flexible rubber trailing and mobile equipment cable series alongside screened OnGcekż-G, serving underground auxiliary drives, movable quarry switchgear, open-pit belt-conveyor shiftable stations and excavator control loops.

Not every mobile or semi-mobile mine feeder uses elastomeric conductive phase screens: auxiliary pumps, portable fans, drill-rig distribution boxes and open-pit 6 kV skid feeders often specify unscreened symmetrical split-earth constructions for simpler field termination and compact outer diameter. OnGc-G pairs EN 60228 Class 5 tinned copper with 90 °C IEP ethylene-propylene rubber (EPR), three interstitial green-yellow earth cores (e.g. 3×50+3×25/3 mm², 233 A) and a tear-resistant yellow ON4 chloroprene sheath; OnG covers general 1×16–1×185 and 2–5 core 0.6/1 kV leads; OGc steps up to 3.6/6 kV (12 kV AC test) with semiconductive field control and a red flame-retardant rubber sheath; and 8GTL3Gkon-G provides 3 to 20 EPR twisted pairs under a tinned-copper kon monitoring braid for open-pit automation.

Where gassy underground coal faces mandate individual or collective elastomeric/copper screens with pilot cores, select OnGcekż-G, OnGcekżi-G or OnGcekż-GW instead.

Explore the mining and tunneling cable range for related configurations.

Construction

OnG, OnGc-G, OGc & 8GTL3Gkon-G Rubber Cable Construction

All four designations use finely stranded Class 5 tinned annealed copper conductors and heavy-duty oil- and flame-resistant ON3 / ON4 mining elastomers.

Clean 2D engineering cross-section of OnGc-G 3x50+3x25/3 flexible rubber mining cable showing three Class 5 tinned-copper EPR phase cores, three interstitial split earth cores, separator tape and matte-black chloroprene outer sheath
OnGc-G cross-section: symmetrical 3+3 split-earth Class 5 tinned-copper geometry inside heavy mining rubber.
OnG, OnGc-G, OGc (0.6/1 & 3.6/6 kV) & 8GTL3Gkon-G Flexible Rubber Underground & Open-Pit Mining Cable construction
ComponentMaterial and construction
1. Flexible tinned copper conductorsMulti-stranded tinned annealed copper, Class 5 to EN / IEC 60228, resisting sulphide tarnishing and moist mine atmospheres.
2. Elastomer core insulationOnG: 60 °C IE1 rubber; OnGc-G & 8GTL3Gkon-G: 90 °C IEP EPR rubber; OGc 3.6/6 kV: inner semiconductive layer + 90 °C EPR + outer semiconductive layer.
3. Symmetrical split earths / pairsOnGc-G & OGc place three split protective-earth conductors symmetrically in the phase interstices; 8GTL3Gkon-G twists 1.0 mm² pairs inside an inner rubber sheath and tinned-copper kon braid.
4. Inner sheath (double-sheath builds)Extruded rubber inner bedding stabilizing core geometry on OnGc-G, OGc and 8GTL3Gkon-G.
5. Heavy-duty ON3 / ON4 outer sheathOil-resistant, flame-retardant rubber (LOI > 29, EN 60332-1-2): yellow on OnGc-G 0.6/1 kV, red on OGc 3.6/6 kV, black/yellow on OnG and 8GTL3Gkon-G.

OnG / OnGc-G / OGc / 8GTL3Gkon-G Designation Breakdown

  • O / On: Mobile rubber cable; 'n' denotes oil-resistant, flame-retardant chloroprene outer sheath (LOI > 29)
  • G: Mining construction with Class 5 tinned copper conductors; suffix '-G' marks underground mine approval geometry
  • c: Heat-resistant 90 °C ethylene-propylene rubber (IEP / EPR) core insulation (OnGc-G and 3.6/6 kV OGc)
  • 3xS+3xs/3: Three main phase cores plus a split protective-earth cross-section divided equally into three interstices
  • 8GTL3Gkon-G: 300/500 V EPR-insulated twisted-pair open-pit control cable with tinned-copper kon monitoring braid
Applications

OnG, OnGc-G & OGc Underground and Open-Pit Mining Applications

Matched to underground auxiliary machinery, quarries and open-pit lignite / copper / aggregate mines.

Underground mine auxiliary extraction room showing matte-black flexible OnG / OnGc-G rubber power cable routed on rock-wall hooks from a skid-mounted gate-end box to an electric loader
Typical duty: flexible 0.6/1 kV OnG / OnGc-G underground auxiliary feeders and 3.6/6 kV OGc open-pit skid cables.
  • Underground 0.6/1 kV auxiliary pumps, portable ventilation fans, grout mixers and mobile distribution skids (OnG and 90 °C OnGc-G).
  • Open-pit mine and quarry 3.6/6 kV movable transformer skids, crushers and shiftable conveyor drive stations (OGc).
  • Open-pit excavator, spreader and belt-conveyor monitored control, telemetry and safety-interlock loops (8GTL3Gkon-G 300/500 V).

OnGc-G & OGc vs Screened OnGcekż-G and (N)TSCGEWÖU-TR

OnGc-G & OnG vs OGc (3.6/6 kV) vs OnGcekż-G vs (N)TSCGEWÖU-TR
Mining rubber cableRated U0/UScreening & pilotsPrimary mining duty
OnGc-G / OnG (this page)0.6/1 kVUnscreened; 3 split earths on OnGc-GAuxiliary underground & quarry 0.6/1 kV mobile loads
OGc (this page)3.6/6 kVMV semicond. layers + 3 split earthsOpen-pit & quarry 6 kV movable skids and conveyors
OnGcekż-G / OnGcekżi-G0.6/1 & 3.6/6 kVConductive/Cu screens + pilot coreGassy underground coal-face shearers & roadheaders
(N)TSCGEWÖU-TR3.6/6 to 18/30 kVVDE 0250-813 MV trailing constructionHeavy open-pit electric rope shovels & draglines

Quick distinction: the suffix 'ekż' in Polish mining cables adds elastomeric/copper phase screens plus an auxiliary pilot core; OnG, OnGc-G and OGc omit those screens for simpler auxiliary and open-pit feeders.

OnG, OnGc-G, OGc & 8GTL3Gkon-G RFQ Checklist

  • Exact designation: OnG (0.6/1 kV), OnGc-G (0.6/1 kV 90 °C), OGc (3.6/6 kV) or 8GTL3Gkon-G (300/500 V pairs).
  • Cross-section or pair count (e.g. OnGc-G 3x50+3x25/3, OGc 3x70+3x16, or 8GTL3Gkon-G 10x2x1.0).
  • Underground vs open-pit UV exposure and preferred sheath colour (yellow LV, red MV, or black open-pit).
  • Cable gland entry diameter range and drum cut lengths.
  • Total meterage and delivery schedule (MOQ 50 m; 7 to 45 working days).

Related selection resources

OnG, OnGc-G, OGc & 8GTL3Gkon-G Mining Cable FAQ

How does OnGc-G differ from standard OnG at 0.6/1 kV?

90 °C vs 60 °C thermal rating and earthing layout: OnGc-G uses 90 °C IEP EPR insulation, three symmetrical split earths (e.g. 3x50+3x25/3) and an ON4 yellow double sheath, whereas OnG uses 60 °C IE1 rubber in single- or standard multi-core layouts.

Should I choose OnGcekż-G instead of OnGc-G or OnG/OGc on gassy coal faces?

Yes. Whenever underground coal or methane regulations require screened power cores and a pilot earth-monitoring conductor, choose OnGcekż-G; OnGc-G and OGc are unscreened split-earth feeders.

How does 8GTL3Gkon-G pair with OnG and OnGc-G in open-pit mines?

300/500 V twisted-pair control, telemetry and safety-interlock wiring (3x2x1.0 to 20x2x1.0 mm²) protected by 90 °C EPR insulation, a tinned-copper kon monitoring braid and an ON3 rubber jacket.

What test voltage applies to 3.6/6 kV OnG/OGc cables?

12,000 V (12 kV) 50 Hz AC factory dielectric testing across the semiconductive-screened 90 °C EPR phase insulation.

What are the MOQ and manufacturing lead time for OnG, OnGc-G and OGc?

50 m minimum order quantity with a production lead time of 7 to 45 working days.

Specifications

OnG, OnGc-G, OGc & 8GTL3Gkon-G Technical Data and Schedule

OnG, OnGc-G & OGc Key Voltage, Ampacity and Bend Ratings

  • OnGc-G 0.6/1 kV (90 °C): Class 5 tinned Cu, 90 °C IEP EPR, symmetrical 3+3 split earths (3x6+3x6/3 to 3x120+3x35/3) and safety-yellow ON4 rubber
  • OnG 0.6/1 kV utility: Single-core (1x16 to 1x185) and multi-core (2x2.5 to 5x16 mm²) Class 5 tinned Cu in flame-retardant ON3 chloroprene
  • OGc 3.6/6 kV open-pit MV: Semiconductive-controlled 90 °C EPR with 3 interstitial earths (3x16+3x6 to 3x95+3x16), tested at 12 kV AC in red rubber
  • 8GTL3Gkon-G 300/500 V: 3x2x1.0 to 20x2x1.0 EPR twisted-pair open-pit control cable with tinned-copper kon monitoring screen
  • Flame & cold resilience: Self-extinguishing LOI > 29 elastomer jackets (EN 60332-1-2) rated down to -40 °C; MOQ 50 m in 7 to 45 working days
OnG, OnGc-G, OGc (0.6/1 & 3.6/6 kV) & 8GTL3Gkon-G Flexible Rubber Underground & Open-Pit Mining Cable technical data
ParameterValue
Rated voltageOnG and OnGc-G: 0.6/1 kV (3 kV AC test); OGc: 3.6/6 kV (12 kV AC test); 8GTL3Gkon-G: 300/500 V (2 kV test)
Conductor and core rangeClass 5 tinned Cu: OnG 1x16-1x185 and 2x2.5-5x16; OnGc-G 3x6+3x6/3-3x120+3x35/3; OGc 3x16+3x6-3x95+3x16
Operating temperature-40 °C to +70 °C ambient; max conductor 90 °C on OnGc-G, OGc and 8GTL3Gkon-G (250 °C fault), 60 °C on OnG
Sheath compound and colourON3 / ON4 oil-resistant flame-retardant rubber (LOI above 29): yellow 0.6/1 kV OnGc-G, red 3.6/6 kV OGc
Minimum bend radius6 x OD fixed / 10 x OD mobile on OnG, OnGc-G and 8GTL3Gkon-G; 10 to 12 x OD on 3.6/6 kV OGc
Supply termsMOQ 50 m; manufacturing lead time 7 to 45 working days

OnG & OnGc-G (0.6/1 kV), OGc (3.6/6 kV) & 8GTL3Gkon-G (300/500 V) Schedule

Representative Polish-standard flexible rubber mining power and open-pit paired control sizes — nominal voltage, insulation/sheath system, approximate outer diameter, 25 °C free-air ampacity (power feeders) and approximate cable weight
Type and cross-sectionRated U0/UInsulation / sheath systemApprox. OD (mm)Current 25 °C air (A)Approx. weight (kg/km)Next step
OnG 1x250.6/1 kV60 °C IE1 / ON3 rubber16.5—498Request this size
OnG 1x500.6/1 kV60 °C IE1 / ON3 rubber20.1—789Request this size
OnG 1x950.6/1 kV60 °C IE1 / ON3 rubber25.0—1,348Request this size
OnG 1x1850.6/1 kV60 °C IE1 / ON3 rubber31.4—2,325Request this size
OnG 3x4+40.6/1 kV60 °C IE1 / ON3 rubber21.4—534Request this size
OnG 3x10+100.6/1 kV60 °C IE1 / ON3 rubber28.4—1,011Request this size
OnG 3x16+100.6/1 kV60 °C IE1 / ON3 rubber33.4—1,400Request this size
OnGc-G 3x16+3x10/30.6/1 kV90 °C IEP EPR / yellow ON424.91181,095Request this size
OnGc-G 3x25+3x16/30.6/1 kV90 °C IEP EPR / yellow ON428.31521,557Request this size
OnGc-G 3x35+3x16/30.6/1 kV90 °C IEP EPR / yellow ON431.81871,952Request this size
OnGc-G 3x50+3x25/30.6/1 kV90 °C IEP EPR / yellow ON436.72332,660Request this size
OnGc-G 3x70+3x25/30.6/1 kV90 °C IEP EPR / yellow ON440.82883,493Request this size
OnGc-G 3x95+3x35/30.6/1 kV90 °C IEP EPR / yellow ON446.83454,594Request this size
OnGc-G 3x120+3x35/30.6/1 kV90 °C IEP EPR / yellow ON450.24005,474Request this size
OnG/OGc 3x16+3x63.6/6 kV90 °C EPR + semicond. / red rubber50.01112,600Request this size
OnG/OGc 3x25+3x63.6/6 kV90 °C EPR + semicond. / red rubber54.91433,100Request this size
OnG/OGc 3x35+3x63.6/6 kV90 °C EPR + semicond. / red rubber60.21753,900Request this size
OnG/OGc 3x50+3x103.6/6 kV90 °C EPR + semicond. / red rubber63.52154,700Request this size
OnG/OGc 3x70+3x163.6/6 kV90 °C EPR + semicond. / red rubber69.02655,800Request this size
OnG/OGc 3x95+3x163.6/6 kV90 °C EPR + semicond. / red rubber72.13176,750Request this size
OnG/8GTL3Gkon-G 5x2x1.0300/500 VEPR pairs + tinned Cu kon / ON316.2—338Request this size
OnG/8GTL3Gkon-G 10x2x1.0300/500 VEPR pairs + tinned Cu kon / ON320.3—525Request this size
OnG/8GTL3Gkon-G 20x2x1.0300/500 VEPR pairs + tinned Cu kon / ON325.9—849Request this size

Additional OnG multi-core sizes (2x2.5 to 2x16, 3x2.5+2.5, 3x6+6, 4x2.5 to 4x25, 5x2.5 to 5x16 mm²), OnGc-G 3x6+3x6/3 & 3x10+3x10/3, and 8GTL3Gkon-G 3, 4, 7, 12, 14 & 16-pair builds are supplied to order.

For screened longwall shearer, roadheader and gassy coal-face feeders with pilot cores, specify OnGcekż-G, OnGcekżi-G, OnGcekż-G2 or OnGcekż-GW.

ASCII part references: OnG 1x95 0.6/1 kV; OnGc-G 3x50+3x25/3 0.6/1 kV; OGc 3x70+3x16 3.6/6 kV; 8GTL3Gkon-G 10x2x1.0 300/500 V.

Standards

OnG, OnGc-G & OGc Elastomer Flame and Oil Standards

OnG, OnGc-G, OGc (0.6/1 & 3.6/6 kV) & 8GTL3Gkon-G Flexible Rubber Underground & Open-Pit Mining Cable standards and test references
Standard or specificationApplication
EN / IEC 60228Class 5 finely stranded tinned annealed copper conductors.
PN-G-90100 / WT Mining Elastomer PracticeIE1 / IEP EPR insulation and ON3 / ON4 tear- and oil-resistant mining rubber sheaths.
EN / IEC 60332-1-2 & IEC 60811-404Flame-retardant (LOI > 29) and mineral-oil-resistant elastomer verification.

Certifications and document support

TEBAOFLEX ISO quality assurance and routine factory test reports

IEC Webstore — IEC 60228, IEC 60502, IEC 60332 and IEC 60793 standards references

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.