High Temperature Cables TEBAOFLEX

UL 3139 & UL 3367 Braidless Silicone Hook-Up Wire (300/600 V, 200 °C)

Engineered to UL AWM Style 3139 (600 V, 45-mil wall) and Style 3367 (300 V, 15-mil wall) specifications, TEBAOFLEX braidless silicone hook-up wires pair solid or stranded ASTM B33 tinned copper conductors (24 AWG to 10 AWG) with extruded 200 °C flame-retardant silicone rubber insulation (-60 °C to +200 °C) for clean, fray-free internal appliance and enclosure harnesses.

Product information
SKU
TF-UL3139-UL3367
Brand
TEBAOFLEX
Product overview

TEBAOFLEX braidless 200 °C silicone hook-up wires engineered to UL AWM Style 3139 (600 V, 45 mils / 1.14 mm nominal wall), Style 3367 (300 V, 15 mils / 0.38 mm thin wall) and companion Style 3530 (600 V, 30 mils / 0.76 mm medium wall) specifications cover 24 AWG through 10 AWG across 1.27 mm (0.050 in) to 4.90 mm (0.193 in) nominal outer diameter and 3.0 to 65.5 kg/km (2 to 44 lbs/kft) linear mass.

In medical sterilizers, semiconductor wet benches, commercial convection ovens and LED luminaire drivers, fiberglass-braided wires such as Style 3122 or SF-2 can shed glass particulates during high-speed rotary stripping and contaminate optical or cleanroom assemblies. Extruding a dense, self-extinguishing silicone elastomer directly over tin-plated copper conductors eliminates glass-braid fraying, lowers finished harness diameter by up to 35% on 15-mil Style 3367, and preserves -60 °C to +200 °C flexibility.

Specify Style 3367 (300 V, 15 mils) for high-density sensor and control harnesses inside totally enclosed appliances, Style 3530 (600 V, 30 mils) for compact 600 V internal cabinet wiring, or Style 3139 (600 V, 45 mils) for 600 V power leads requiring extra dielectric margin; choose fiberglass-braided Style 3122 / SF-2 where wires cross sharp sheet-metal edges. Supplied on 305 m (1,000 ft) or 500 m spools per colour (whereas heavy multicore cables use a 50 m MOQ), with a 7 to 45 working days production lead time.

Explore the high-temperature wire and cable range for related configurations.

Construction

UL 3139 & UL 3367 Braidless Silicone Wire Construction

Each wire is manufactured to UL 758 Appliance Wiring Material (AWM) Style 3139, Style 3367 or Style 3530 and CSA C22.2 No. 210 Class I Group A/B construction and dimensional schedules.

Clean 2D engineering cross-section of Style 3139 braidless 600 V silicone wire showing concentric stranded tinned copper conductor and uniform 45-mil flame-retardant silicone rubber wall
Style 3139 2D cross-section: tin-plated copper conductor enclosed in a concentric extruded silicone elastomer wall without glass braid.
UL 3139 & UL 3367 Braidless Silicone Hook-Up Wire (300/600 V, 200 °C) construction
ComponentMaterial and construction
1. Tin-Plated Copper Conductor (Solid or Concentric Stranded)Annealed ASTM B33 tinned copper in solid constructions (1/24, 1/22, 1/20, 1/18, 1/16, 1/14, 1/12, 1/10) or stranded constructions (7/32, 7/30, 7/28, 7/26, 7/.0192 in, 7/.0242 in, 19/.0185 in, 37/.0167 in); nickel-plated or silver-plated copper available to order.
2. Extruded Flame-Retardant Silicone Rubber InsulationBraidless, smooth-surface cross-linked silicone elastomer formulated for -60 °C to +200 °C continuous service and horizontal/vertical flame resistance without halogen plasticizers.
3. Calibrated Wall-Thickness Profile (15 / 30 / 45 mils)0.38 mm (15 mils) nominal wall on 300 V Style 3367, 0.76 mm (30 mils) nominal wall on 600 V Style 3530, and 1.14 mm (45 mils) nominal wall on 600 V Style 3139.
4. Pigmented Colour Coding & Clean-Strip SurfaceAvailable in black, white, red, blue, brown, yellow, orange, violet, grey and green-yellow with anti-tack surface curing for jam-free feed tubes on automated wire-processing lines.

UL 3139, UL 3367 & UL 3530 Wall Code Breakdown

  • Style 3367 (300 V, 200 °C): 15-mil (0.38 mm) thin-wall extruded flame-retardant braidless silicone insulation over 24 to 18 AWG solid/stranded tinned copper
  • Style 3530 (600 V, 200 °C): 30-mil (0.76 mm) medium-wall (45-mil on 10 AWG) braidless flame-retardant silicone internal appliance wire
  • Style 3139 (600 V, 200 °C): 45-mil (1.14 mm) heavy-wall braidless flame-retardant silicone hook-up wire for 24 to 12 AWG enclosed 600 V circuits
  • Braidless FR Silicone: Self-extinguishing halogen-free silicone rubber eliminating fiberglass shedding during automated stripping
  • ASTM B33 Tinned Cu: Tin-plated annealed copper preventing conductor blackening and preserving solderability at +200 °C
Applications

UL 3139 & UL 3367 Cleanroom & Appliance Applications

Use braidless 200 °C Style 3139, Style 3367 and Style 3530 silicone lead wires for internal wiring of totally enclosed electrical equipment, appliances and electronic sub-assemblies.

Cleanroom medical autoclave and LED luminaire driver control assembly wired with smooth red, blue and white braidless 200 °C silicone hook-up harnesses
Enclosed commercial autoclave and luminaire electronics chassis wired with fray-free braidless 200 °C silicone hook-up leads.
  • Commercial bakery ovens, induction cooktops, coffee roasters, food warming cabinets and HVAC electric duct heater control harnesses.
  • Autoclaves, laboratory incubators, cleanroom drying chambers and medical diagnostic enclosures where fiberglass braid dust is prohibited.
  • High-lumen LED high-bay drivers, stage/architectural luminaire ballasts, UV curing housings and transformer secondary leads.
  • Automated cut-strip-terminate OEM wire harnesses requiring tight tolerance outer diameters (0.050 in to 0.179 in) and zero braid unravelling.

UL 3139 & UL 3367 vs Style 3123 vs Braided Style 3122 vs SiF

UL 3139 / UL 3367 Braidless Silicone vs UL 3123 (150 °C) vs Braided UL 3122 / SF-2 vs Metric SiF
Wire Style / FamilyVoltage & Temp RatingWall & Outer ProtectionWhen to Specify
UL 3139 & UL 3367 (this page)600 V (Style 3139) / 300 V (Style 3367), 200 °C45-mil or 15-mil braidless FR siliconeFray-free 200 °C AWG internal harnesses for cleanrooms, autoclaves & automated crimping
UL 3123 / UL 3644 Hook-Up Wire600 V (150 °C) / 1,000 V (200 °C)30-mil or 45-mil braidless siliconeStandard 150 °C appliance leads (Style 3123) or 1,000 V inverter/luminaire internal leads (Style 3644)
UL 3122 / SF-1 / SF-2 Braided Wire300 V / 600 V, 200 °CSilicone + outer fiberglass braidRouting across punched metal knockouts, heating elements & abrasive oven bulkheads
Metric SiF / SiFF (VDE 0250)300/500 V, 180 °CMetric Class 5 or Class 6 braidless siliconeEuropean DIN/IEC machinery specifying mm² cross-sections (0.25 to 150 mm²)

Select braidless UL 3139 (600 V) or UL 3367 (300 V) inside clean enclosures and automated crimping lines; switch to fiberglass-braided Style 3122 / SF-2 where leads cross sharp metal edges.

UL 3139 & UL 3367 Braidless Silicone Wire RFQ Checklist

  • Target style and wall profile: 300 V 15-mil Style 3367, 600 V 30-mil Style 3530, or 600 V 45-mil Style 3139.
  • AWG gauge (24 AWG to 10 AWG) and conductor stranding preference (solid 1/XX vs concentric 7-strand vs flexible Class K fine-stranded tinned copper).
  • Insulation colour list and per-colour spool quantity (standard 305 m / 1,000 ft or 500 m spools for automated harness cutting).
  • Enclosure environment: ambient temperature peak (up to +200 °C), air circulation vs sealed housing, and cleanroom particulate constraints.
  • Required factory test report items (spark test, 2.0 kV AC dielectric withstand, DC conductor resistance, insulation OD tolerance) and delivery schedule (7 to 45 working days).

Related selection resources

UL 3139 & UL 3367 Silicone Wire Frequently Asked Questions

What is the difference between UL 3139, UL 3530 and UL 3367 braidless silicone wire?

300 V vs 600 V rated voltage and 15-mil vs 30-mil vs 45-mil silicone wall thickness. Style 3367 uses a 15-mil (0.38 mm) wall rated 300 V, Style 3530 uses a 30-mil (0.76 mm) wall rated 600 V, and Style 3139 uses a 45-mil (1.14 mm) wall rated 600 V; all three operate at 200 °C.

Are TEBAOFLEX UL 3139 and UL 3367 wires third-party marked or engineered to specification?

No third-party AWM mark is claimed; they are engineered to specification. TEBAOFLEX manufactures these braidless 200 °C silicone hook-up wires strictly to UL 758 AWM Style 3139, Style 3367 and Style 3530 dimensional, tinned-copper stranding and flame-retardant compound parameters.

When should OEM harness builders choose braidless UL 3139 or UL 3367 over fiberglass-braided Style 3122?

Yes, choose braidless UL 3139 or UL 3367 whenever 200 °C leads are enclosed inside clean cabinets, medical autoclaves, LED luminaires or automated cut-and-strip lines where shed glass fibres contaminate assemblies; choose fiberglass-braided Style 3122 when wires rub against sharp sheet-metal edges.

What is the minimum order quantity and spool put-up for UL 3139 and UL 3367 wire?

305 m (1,000 ft) or 500 m standard factory spools per colour and AWG size. Unlike heavy multicore industrial cables that ship in 50 m cut lengths, single-core 24 to 10 AWG hook-up wires are wound on continuous machine-ready spools with a 7 to 45 working days lead time.

Can UL 3367 15-mil thin-wall silicone wire be produced in 16 AWG to 10 AWG?

Yes. Although the published UL 3367 style sheet covers 24 AWG through 18 AWG, TEBAOFLEX extrudes matching 15-mil (0.38 mm) 200 °C thin-wall braidless silicone over 16, 14, 12 and 10 AWG stranded tinned copper for space-constrained 300 V OEM internal busbars.

Specifications

UL 3139 (600 V), UL 3367 (300 V) & Style 3530 AWG Schedule

UL 3139 & UL 3367 Key Voltage, Wall, Temp & Spool Summary

  • Three wall-thickness profiles: 15-mil thin-wall Style 3367 (300 V, 24 to 18 AWG plus 16 to 10 AWG OEM extensions), 30-mil medium-wall Style 3530 (600 V) and 45-mil heavy-wall Style 3139 (600 V, 24 to 12 AWG)
  • Zero glass-fibre shedding: Smooth braidless flame-retardant silicone rubber strips cleanly on high-speed automated cut-strip-crimp machines without airborne glass dust
  • Solid & stranded tinned copper: ASTM B33 tin-plated copper in solid (1/24 to 1/10) for push-in PCB/thermostat blocks or stranded (7/26 to 37/.0167 in) for flexible chassis routing
  • Thermal & dielectric stability: -60 °C to +200 °C continuous thermal rating with VW-1 / FT1 flame-retardant compound formulation for enclosed commercial appliances and luminaires
  • Automated-harness spool put-up: Supplied on 305 m (1,000 ft) or 500 m standard factory spools per colour (contrasted with 50 m cut lengths on heavy multicore feeders), 7 to 45 working days lead time
UL 3139 & UL 3367 Braidless Silicone Hook-Up Wire (300/600 V, 200 °C) technical data
ParameterValue
Rated voltage300 V AC on Style 3367 (15-mil wall) and 600 V AC on Style 3139 (45-mil wall) and Style 3530 (30-mil wall)
Gauge and conductor stranding24 AWG to 12 AWG (Style 3139) and 24 AWG to 18 AWG plus 16 to 10 AWG OEM extensions (Style 3367) in solid or stranded ASTM B33 tinned copper
Insulation and constructionExtruded braidless flame-retardant silicone rubber engineered to UL AWM Style 3139, Style 3367 and Style 3530 specifications
Temperature range and bend radius-60 C to +200 C continuous conductor rating with 6x OD minimum fixed internal routing bend radius
Standard put-up and lead time305 m (1000 ft) or 500 m standard factory spools per colour (50 m cut lengths apply only to heavy multicore cables) in 7 to 45 working days
Standards compliance noteEngineered and manufactured to UL 758 AWM Style 3139 / 3367 / 3530 and CSA C22.2 No. 210 Class I Group A dimensional criteria (third-party AWM mark is not claimed)
Automated harness processingSmooth unbraided outer skin compatible with high-speed V-blade and rotary stripping blades without glass-yarn wear

Style 3139 (600 V, 45 mils) & Style 3367 (300 V, 15 mils) Dimensional Schedule

Braidless Silicone Wire Engineered to UL 3139 (600 V, 45 mils) & UL 3367 (300 V, 15 mils) — AWG, Wall, OD & Weight Schedule
Style & AWG SizeRated VoltageStd. Tinned Cu StrandingNom. Wall (mils / mm)Nom. OD (in / mm)Approx. Weight (lbs/kft / kg/km)Standard Put-UpNext step
UL 3139 24 AWG600 V1/24 or 7/3245 / 1.140.114 / 2.907 / 10.4305 m / 500 m spoolRequest this size
UL 3139 22 AWG600 V1/22 or 7/3045 / 1.140.120 / 3.058 / 11.9305 m / 500 m spoolRequest this size
UL 3139 20 AWG600 V1/20 or 7/2845 / 1.140.128 / 3.2510 / 14.9305 m / 500 m spoolRequest this size
UL 3139 18 AWG600 V7/26 or 1/1845 / 1.140.139 / 3.5313 / 19.3305 m / 500 m spoolRequest this size
UL 3139 16 AWG600 V7/.0192" (26/30 opt.)45 / 1.140.148 / 3.7617 / 25.3305 m / 500 m spoolRequest this size
UL 3139 14 AWG600 V7/.0242" (41/30 opt.)45 / 1.140.162 / 4.1122 / 32.7305 m / 500 m spoolRequest this size
UL 3139 12 AWG600 V19/.0185" (65/30 opt.)45 / 1.140.179 / 4.5531 / 46.1305 m spoolRequest this size
UL 3367 24 AWG300 V1/24 or 7/3215 / 0.380.050 / 1.272 / 3.0500 m spoolRequest this size
UL 3367 22 AWG300 V1/22 or 7/3015 / 0.380.055 / 1.403 / 4.5500 m spoolRequest this size
UL 3367 20 AWG300 V1/20 or 7/2815 / 0.380.062 / 1.574 / 6.0500 m spoolRequest this size
UL 3367 18 AWG300 V7/26 or 1/1815 / 0.380.079 / 2.017 / 10.4305 m / 500 m spoolRequest this size
UL 3367 16 AWG (OEM thin-wall)300 V7/.0192"15 / 0.380.088 / 2.2410 / 14.9305 m / 500 m spoolRequest this size
UL 3367 14 AWG (OEM thin-wall)300 V7/.0242"15 / 0.380.102 / 2.5915 / 22.3305 m spoolRequest this size
UL 3367 12 AWG (OEM thin-wall)300 V19/.0185"15 / 0.380.119 / 3.0222 / 32.7305 m spoolRequest this size
UL 3367 10 AWG (OEM thin-wall)300 V37/.0167"15 / 0.380.145 / 3.6832 / 47.6305 m spoolRequest this size

Companion 30-Mil Medium-Wall Schedule (Engineered to UL 3530 600 V, 200 °C)

Companion Medium-Wall Schedule Engineered to UL 3530 (600 V, 200 °C, 30-mil / 45-mil Silicone Wall)
Companion Style & GaugeConductor StrandingNom. Wall (mils / mm)Nom. OD (in / mm)Approx. Weight (lbs/kft / kg/km)Internal Wiring Application
Style 3530 24 AWG1/24 solid30 / 0.760.080 / 2.034 / 6.0Compact 600 V PCB & sensor jumpers
Style 3530 22 AWG1/22 solid30 / 0.760.085 / 2.165 / 7.4Thermostat & relay coil leads
Style 3530 20 AWG1/20 solid30 / 0.760.092 / 2.347 / 10.4Enclosed appliance control harnesses
Style 3530 18 AWG1/18 or 7/2630 / 0.760.100 – 0.109 / 2.54 – 2.779 – 10 / 13.4 – 14.9LED driver & oven control panels
Style 3530 16 AWG1/16 or 7/.0192"30 / 0.760.111 – 0.118 / 2.82 – 3.0012 – 13 / 17.9 – 19.3Heater contactor & ballast leads
Style 3530 14 AWG1/14 or 7/.0242"30 / 0.760.124 – 0.132 / 3.15 – 3.3517 – 18 / 25.3 – 26.8600 V internal power distribution
Style 3530 12 AWG1/12 or 19/.0185"30 / 0.760.141 – 0.149 / 3.58 – 3.7826 – 28 / 38.7 – 41.7High-load appliance element leads
Style 3530 10 AWG1/10 or 19/.0234"45 / 1.140.193 – 0.205 / 4.90 – 5.2144 – 46 / 65.5 – 68.530 A enclosed cabinet feeders

All wires on this page are engineered and manufactured to UL 758 AWM Style 3139, Style 3367 and Style 3530 dimensional, conductor and flame-retardant silicone elastomer specifications (with CSA C22.2 No. 210 Class I Group A reference; third-party AWM style marking is not claimed), and final values are confirmed on the quotation drawing.

In the 15-mil thin-wall Style 3367 table, 24 AWG through 18 AWG correspond to the standard UL 3367 gauge scope, whereas 16, 14, 12 and 10 AWG are non-UL OEM thin-wall extensions built to the same 15-mil (0.38 mm) 200 °C silicone wall profile.

Single-core hook-up sizes (24 to 10 AWG) are supplied on 305 m (1,000 ft) or 500 m standard factory spools per colour (rather than 50 m cut lengths used on heavy multicore power cables), with a manufacturing lead time of 7 to 45 working days.

ASCII part references for BOM and ERP entry: TF-UL3139-24AWG; TF-UL3139-22AWG; TF-UL3139-20AWG; TF-UL3139-18AWG; TF-UL3139-16AWG; TF-UL3139-14AWG; TF-UL3139-12AWG; TF-UL3367-24AWG; TF-UL3367-22AWG; TF-UL3367-20AWG; TF-UL3367-18AWG; TF-UL3367-16AWG; TF-UL3530-18AWG; TF-UL3530-14AWG.

Standards

UL 3139 & UL 3367 Reference Standards (UL 758 & ASTM B33)

UL 3139 & UL 3367 Braidless Silicone Hook-Up Wire (300/600 V, 200 °C) standards and test references
Standard or specificationApplication
UL 758 AWM Style 3139 (600 V, 200 °C, 45-mil Braidless Silicone)Construction and dimensional design reference for heavy-wall 1.14 mm (45 mils) extruded flame-retardant silicone appliance wire in totally enclosed equipment.
UL 758 AWM Style 3367 (300 V, 200 °C, 15-mil Braidless Silicone)Construction and dimensional design reference for ultra-thin 0.38 mm (15 mils) extruded flame-retardant silicone hook-up wire (24 to 18 AWG).
UL 758 AWM Style 3530 (600 V, 200 °C, 30-mil Braidless Silicone)Medium-wall 0.76 mm (30 mils) 600 V braidless silicone design reference bridging thin-wall Style 3367 and heavy-wall Style 3139.
ASTM B33 & CSA C22.2 No. 210 (Class I Group A Reference)Tin-coated soft or annealed copper wire specification and Canadian internal equipment appliance-wire dimensional reference. Note: TEBAOFLEX holds UL 62 ZJCZ flexible-cord certification (UL-US-2449012-4); Style 3139/3367/3530 wires are supplied as engineered-to-specification OEM constructions without UL Marking.

Certifications and document support

TEBAOFLEX ISO 9001 quality system and verified certificate scope documentation

UL 758 — Appliance Wiring Material (AWM) Style Construction Framework

ASTM B33 — Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.