Engineered to UL AWM Style 3139 (600 V, 45-mil wall) and Style 3367 (300 V, 15-mil wall) specifications, TEBAOFLEX braidless silicone hook-up wires pair solid or stranded ASTM B33 tinned copper conductors (24 AWG to 10 AWG) with extruded 200 °C flame-retardant silicone rubber insulation (-60 °C to +200 °C) for clean, fray-free internal appliance and enclosure harnesses.
TEBAOFLEX braidless 200 °C silicone hook-up wires engineered to UL AWM Style 3139 (600 V, 45 mils / 1.14 mm nominal wall), Style 3367 (300 V, 15 mils / 0.38 mm thin wall) and companion Style 3530 (600 V, 30 mils / 0.76 mm medium wall) specifications cover 24 AWG through 10 AWG across 1.27 mm (0.050 in) to 4.90 mm (0.193 in) nominal outer diameter and 3.0 to 65.5 kg/km (2 to 44 lbs/kft) linear mass.
In medical sterilizers, semiconductor wet benches, commercial convection ovens and LED luminaire drivers, fiberglass-braided wires such as Style 3122 or SF-2 can shed glass particulates during high-speed rotary stripping and contaminate optical or cleanroom assemblies. Extruding a dense, self-extinguishing silicone elastomer directly over tin-plated copper conductors eliminates glass-braid fraying, lowers finished harness diameter by up to 35% on 15-mil Style 3367, and preserves -60 °C to +200 °C flexibility.
Specify Style 3367 (300 V, 15 mils) for high-density sensor and control harnesses inside totally enclosed appliances, Style 3530 (600 V, 30 mils) for compact 600 V internal cabinet wiring, or Style 3139 (600 V, 45 mils) for 600 V power leads requiring extra dielectric margin; choose fiberglass-braided Style 3122 / SF-2 where wires cross sharp sheet-metal edges. Supplied on 305 m (1,000 ft) or 500 m spools per colour (whereas heavy multicore cables use a 50 m MOQ), with a 7 to 45 working days production lead time.
Explore the high-temperature wire and cable range for related configurations.
UL 3139 & UL 3367 Braidless Silicone Wire Construction
Each wire is manufactured to UL 758 Appliance Wiring Material (AWM) Style 3139, Style 3367 or Style 3530 and CSA C22.2 No. 210 Class I Group A/B construction and dimensional schedules.

| Component | Material and construction |
|---|---|
| 1. Tin-Plated Copper Conductor (Solid or Concentric Stranded) | Annealed ASTM B33 tinned copper in solid constructions (1/24, 1/22, 1/20, 1/18, 1/16, 1/14, 1/12, 1/10) or stranded constructions (7/32, 7/30, 7/28, 7/26, 7/.0192 in, 7/.0242 in, 19/.0185 in, 37/.0167 in); nickel-plated or silver-plated copper available to order. |
| 2. Extruded Flame-Retardant Silicone Rubber Insulation | Braidless, smooth-surface cross-linked silicone elastomer formulated for -60 °C to +200 °C continuous service and horizontal/vertical flame resistance without halogen plasticizers. |
| 3. Calibrated Wall-Thickness Profile (15 / 30 / 45 mils) | 0.38 mm (15 mils) nominal wall on 300 V Style 3367, 0.76 mm (30 mils) nominal wall on 600 V Style 3530, and 1.14 mm (45 mils) nominal wall on 600 V Style 3139. |
| 4. Pigmented Colour Coding & Clean-Strip Surface | Available in black, white, red, blue, brown, yellow, orange, violet, grey and green-yellow with anti-tack surface curing for jam-free feed tubes on automated wire-processing lines. |
UL 3139, UL 3367 & UL 3530 Wall Code Breakdown
- Style 3367 (300 V, 200 °C): 15-mil (0.38 mm) thin-wall extruded flame-retardant braidless silicone insulation over 24 to 18 AWG solid/stranded tinned copper
- Style 3530 (600 V, 200 °C): 30-mil (0.76 mm) medium-wall (45-mil on 10 AWG) braidless flame-retardant silicone internal appliance wire
- Style 3139 (600 V, 200 °C): 45-mil (1.14 mm) heavy-wall braidless flame-retardant silicone hook-up wire for 24 to 12 AWG enclosed 600 V circuits
- Braidless FR Silicone: Self-extinguishing halogen-free silicone rubber eliminating fiberglass shedding during automated stripping
- ASTM B33 Tinned Cu: Tin-plated annealed copper preventing conductor blackening and preserving solderability at +200 °C
UL 3139 & UL 3367 Cleanroom & Appliance Applications
Use braidless 200 °C Style 3139, Style 3367 and Style 3530 silicone lead wires for internal wiring of totally enclosed electrical equipment, appliances and electronic sub-assemblies.

- Commercial bakery ovens, induction cooktops, coffee roasters, food warming cabinets and HVAC electric duct heater control harnesses.
- Autoclaves, laboratory incubators, cleanroom drying chambers and medical diagnostic enclosures where fiberglass braid dust is prohibited.
- High-lumen LED high-bay drivers, stage/architectural luminaire ballasts, UV curing housings and transformer secondary leads.
- Automated cut-strip-terminate OEM wire harnesses requiring tight tolerance outer diameters (0.050 in to 0.179 in) and zero braid unravelling.
UL 3139 & UL 3367 vs Style 3123 vs Braided Style 3122 vs SiF
| Wire Style / Family | Voltage & Temp Rating | Wall & Outer Protection | When to Specify |
|---|---|---|---|
| UL 3139 & UL 3367 (this page) | 600 V (Style 3139) / 300 V (Style 3367), 200 °C | 45-mil or 15-mil braidless FR silicone | Fray-free 200 °C AWG internal harnesses for cleanrooms, autoclaves & automated crimping |
| UL 3123 / UL 3644 Hook-Up Wire | 600 V (150 °C) / 1,000 V (200 °C) | 30-mil or 45-mil braidless silicone | Standard 150 °C appliance leads (Style 3123) or 1,000 V inverter/luminaire internal leads (Style 3644) |
| UL 3122 / SF-1 / SF-2 Braided Wire | 300 V / 600 V, 200 °C | Silicone + outer fiberglass braid | Routing across punched metal knockouts, heating elements & abrasive oven bulkheads |
| Metric SiF / SiFF (VDE 0250) | 300/500 V, 180 °C | Metric Class 5 or Class 6 braidless silicone | European DIN/IEC machinery specifying mm² cross-sections (0.25 to 150 mm²) |
Select braidless UL 3139 (600 V) or UL 3367 (300 V) inside clean enclosures and automated crimping lines; switch to fiberglass-braided Style 3122 / SF-2 where leads cross sharp metal edges.
UL 3139 & UL 3367 Braidless Silicone Wire RFQ Checklist
- Target style and wall profile: 300 V 15-mil Style 3367, 600 V 30-mil Style 3530, or 600 V 45-mil Style 3139.
- AWG gauge (24 AWG to 10 AWG) and conductor stranding preference (solid 1/XX vs concentric 7-strand vs flexible Class K fine-stranded tinned copper).
- Insulation colour list and per-colour spool quantity (standard 305 m / 1,000 ft or 500 m spools for automated harness cutting).
- Enclosure environment: ambient temperature peak (up to +200 °C), air circulation vs sealed housing, and cleanroom particulate constraints.
- Required factory test report items (spark test, 2.0 kV AC dielectric withstand, DC conductor resistance, insulation OD tolerance) and delivery schedule (7 to 45 working days).
Related selection resources
- Full high-temperature silicone, fluoropolymer and mica-glass wire catalog
- Multi-style 105–250 °C silicone appliance hook-up wire overview
- Braided 200 °C silicone lead wire (Style 3122 / SF-1 / SF-2) for abrasive routing
- SiF metric 180 °C braidless single-core silicone wire (0.25 to 150 mm²)
- Engineering guide: Silicone vs PTFE/FEP/PFA vs mica-glass temperature limits
UL 3139 & UL 3367 Silicone Wire Frequently Asked Questions
What is the difference between UL 3139, UL 3530 and UL 3367 braidless silicone wire?
300 V vs 600 V rated voltage and 15-mil vs 30-mil vs 45-mil silicone wall thickness. Style 3367 uses a 15-mil (0.38 mm) wall rated 300 V, Style 3530 uses a 30-mil (0.76 mm) wall rated 600 V, and Style 3139 uses a 45-mil (1.14 mm) wall rated 600 V; all three operate at 200 °C.
Are TEBAOFLEX UL 3139 and UL 3367 wires third-party marked or engineered to specification?
No third-party AWM mark is claimed; they are engineered to specification. TEBAOFLEX manufactures these braidless 200 °C silicone hook-up wires strictly to UL 758 AWM Style 3139, Style 3367 and Style 3530 dimensional, tinned-copper stranding and flame-retardant compound parameters.
When should OEM harness builders choose braidless UL 3139 or UL 3367 over fiberglass-braided Style 3122?
Yes, choose braidless UL 3139 or UL 3367 whenever 200 °C leads are enclosed inside clean cabinets, medical autoclaves, LED luminaires or automated cut-and-strip lines where shed glass fibres contaminate assemblies; choose fiberglass-braided Style 3122 when wires rub against sharp sheet-metal edges.
What is the minimum order quantity and spool put-up for UL 3139 and UL 3367 wire?
305 m (1,000 ft) or 500 m standard factory spools per colour and AWG size. Unlike heavy multicore industrial cables that ship in 50 m cut lengths, single-core 24 to 10 AWG hook-up wires are wound on continuous machine-ready spools with a 7 to 45 working days lead time.
Can UL 3367 15-mil thin-wall silicone wire be produced in 16 AWG to 10 AWG?
Yes. Although the published UL 3367 style sheet covers 24 AWG through 18 AWG, TEBAOFLEX extrudes matching 15-mil (0.38 mm) 200 °C thin-wall braidless silicone over 16, 14, 12 and 10 AWG stranded tinned copper for space-constrained 300 V OEM internal busbars.
UL 3139 (600 V), UL 3367 (300 V) & Style 3530 AWG Schedule
UL 3139 & UL 3367 Key Voltage, Wall, Temp & Spool Summary
- Three wall-thickness profiles: 15-mil thin-wall Style 3367 (300 V, 24 to 18 AWG plus 16 to 10 AWG OEM extensions), 30-mil medium-wall Style 3530 (600 V) and 45-mil heavy-wall Style 3139 (600 V, 24 to 12 AWG)
- Zero glass-fibre shedding: Smooth braidless flame-retardant silicone rubber strips cleanly on high-speed automated cut-strip-crimp machines without airborne glass dust
- Solid & stranded tinned copper: ASTM B33 tin-plated copper in solid (1/24 to 1/10) for push-in PCB/thermostat blocks or stranded (7/26 to 37/.0167 in) for flexible chassis routing
- Thermal & dielectric stability: -60 °C to +200 °C continuous thermal rating with VW-1 / FT1 flame-retardant compound formulation for enclosed commercial appliances and luminaires
- Automated-harness spool put-up: Supplied on 305 m (1,000 ft) or 500 m standard factory spools per colour (contrasted with 50 m cut lengths on heavy multicore feeders), 7 to 45 working days lead time
| Parameter | Value |
|---|---|
| Rated voltage | 300 V AC on Style 3367 (15-mil wall) and 600 V AC on Style 3139 (45-mil wall) and Style 3530 (30-mil wall) |
| Gauge and conductor stranding | 24 AWG to 12 AWG (Style 3139) and 24 AWG to 18 AWG plus 16 to 10 AWG OEM extensions (Style 3367) in solid or stranded ASTM B33 tinned copper |
| Insulation and construction | Extruded braidless flame-retardant silicone rubber engineered to UL AWM Style 3139, Style 3367 and Style 3530 specifications |
| Temperature range and bend radius | -60 C to +200 C continuous conductor rating with 6x OD minimum fixed internal routing bend radius |
| Standard put-up and lead time | 305 m (1000 ft) or 500 m standard factory spools per colour (50 m cut lengths apply only to heavy multicore cables) in 7 to 45 working days |
| Standards compliance note | Engineered and manufactured to UL 758 AWM Style 3139 / 3367 / 3530 and CSA C22.2 No. 210 Class I Group A dimensional criteria (third-party AWM mark is not claimed) |
| Automated harness processing | Smooth unbraided outer skin compatible with high-speed V-blade and rotary stripping blades without glass-yarn wear |
Style 3139 (600 V, 45 mils) & Style 3367 (300 V, 15 mils) Dimensional Schedule
| Style & AWG Size | Rated Voltage | Std. Tinned Cu Stranding | Nom. Wall (mils / mm) | Nom. OD (in / mm) | Approx. Weight (lbs/kft / kg/km) | Standard Put-Up | Next step |
|---|---|---|---|---|---|---|---|
| UL 3139 24 AWG | 600 V | 1/24 or 7/32 | 45 / 1.14 | 0.114 / 2.90 | 7 / 10.4 | 305 m / 500 m spool | Request this size |
| UL 3139 22 AWG | 600 V | 1/22 or 7/30 | 45 / 1.14 | 0.120 / 3.05 | 8 / 11.9 | 305 m / 500 m spool | Request this size |
| UL 3139 20 AWG | 600 V | 1/20 or 7/28 | 45 / 1.14 | 0.128 / 3.25 | 10 / 14.9 | 305 m / 500 m spool | Request this size |
| UL 3139 18 AWG | 600 V | 7/26 or 1/18 | 45 / 1.14 | 0.139 / 3.53 | 13 / 19.3 | 305 m / 500 m spool | Request this size |
| UL 3139 16 AWG | 600 V | 7/.0192" (26/30 opt.) | 45 / 1.14 | 0.148 / 3.76 | 17 / 25.3 | 305 m / 500 m spool | Request this size |
| UL 3139 14 AWG | 600 V | 7/.0242" (41/30 opt.) | 45 / 1.14 | 0.162 / 4.11 | 22 / 32.7 | 305 m / 500 m spool | Request this size |
| UL 3139 12 AWG | 600 V | 19/.0185" (65/30 opt.) | 45 / 1.14 | 0.179 / 4.55 | 31 / 46.1 | 305 m spool | Request this size |
| UL 3367 24 AWG | 300 V | 1/24 or 7/32 | 15 / 0.38 | 0.050 / 1.27 | 2 / 3.0 | 500 m spool | Request this size |
| UL 3367 22 AWG | 300 V | 1/22 or 7/30 | 15 / 0.38 | 0.055 / 1.40 | 3 / 4.5 | 500 m spool | Request this size |
| UL 3367 20 AWG | 300 V | 1/20 or 7/28 | 15 / 0.38 | 0.062 / 1.57 | 4 / 6.0 | 500 m spool | Request this size |
| UL 3367 18 AWG | 300 V | 7/26 or 1/18 | 15 / 0.38 | 0.079 / 2.01 | 7 / 10.4 | 305 m / 500 m spool | Request this size |
| UL 3367 16 AWG (OEM thin-wall) | 300 V | 7/.0192" | 15 / 0.38 | 0.088 / 2.24 | 10 / 14.9 | 305 m / 500 m spool | Request this size |
| UL 3367 14 AWG (OEM thin-wall) | 300 V | 7/.0242" | 15 / 0.38 | 0.102 / 2.59 | 15 / 22.3 | 305 m spool | Request this size |
| UL 3367 12 AWG (OEM thin-wall) | 300 V | 19/.0185" | 15 / 0.38 | 0.119 / 3.02 | 22 / 32.7 | 305 m spool | Request this size |
| UL 3367 10 AWG (OEM thin-wall) | 300 V | 37/.0167" | 15 / 0.38 | 0.145 / 3.68 | 32 / 47.6 | 305 m spool | Request this size |
Companion 30-Mil Medium-Wall Schedule (Engineered to UL 3530 600 V, 200 °C)
| Companion Style & Gauge | Conductor Stranding | Nom. Wall (mils / mm) | Nom. OD (in / mm) | Approx. Weight (lbs/kft / kg/km) | Internal Wiring Application |
|---|---|---|---|---|---|
| Style 3530 24 AWG | 1/24 solid | 30 / 0.76 | 0.080 / 2.03 | 4 / 6.0 | Compact 600 V PCB & sensor jumpers |
| Style 3530 22 AWG | 1/22 solid | 30 / 0.76 | 0.085 / 2.16 | 5 / 7.4 | Thermostat & relay coil leads |
| Style 3530 20 AWG | 1/20 solid | 30 / 0.76 | 0.092 / 2.34 | 7 / 10.4 | Enclosed appliance control harnesses |
| Style 3530 18 AWG | 1/18 or 7/26 | 30 / 0.76 | 0.100 – 0.109 / 2.54 – 2.77 | 9 – 10 / 13.4 – 14.9 | LED driver & oven control panels |
| Style 3530 16 AWG | 1/16 or 7/.0192" | 30 / 0.76 | 0.111 – 0.118 / 2.82 – 3.00 | 12 – 13 / 17.9 – 19.3 | Heater contactor & ballast leads |
| Style 3530 14 AWG | 1/14 or 7/.0242" | 30 / 0.76 | 0.124 – 0.132 / 3.15 – 3.35 | 17 – 18 / 25.3 – 26.8 | 600 V internal power distribution |
| Style 3530 12 AWG | 1/12 or 19/.0185" | 30 / 0.76 | 0.141 – 0.149 / 3.58 – 3.78 | 26 – 28 / 38.7 – 41.7 | High-load appliance element leads |
| Style 3530 10 AWG | 1/10 or 19/.0234" | 45 / 1.14 | 0.193 – 0.205 / 4.90 – 5.21 | 44 – 46 / 65.5 – 68.5 | 30 A enclosed cabinet feeders |
All wires on this page are engineered and manufactured to UL 758 AWM Style 3139, Style 3367 and Style 3530 dimensional, conductor and flame-retardant silicone elastomer specifications (with CSA C22.2 No. 210 Class I Group A reference; third-party AWM style marking is not claimed), and final values are confirmed on the quotation drawing.
In the 15-mil thin-wall Style 3367 table, 24 AWG through 18 AWG correspond to the standard UL 3367 gauge scope, whereas 16, 14, 12 and 10 AWG are non-UL OEM thin-wall extensions built to the same 15-mil (0.38 mm) 200 °C silicone wall profile.
Single-core hook-up sizes (24 to 10 AWG) are supplied on 305 m (1,000 ft) or 500 m standard factory spools per colour (rather than 50 m cut lengths used on heavy multicore power cables), with a manufacturing lead time of 7 to 45 working days.
ASCII part references for BOM and ERP entry: TF-UL3139-24AWG; TF-UL3139-22AWG; TF-UL3139-20AWG; TF-UL3139-18AWG; TF-UL3139-16AWG; TF-UL3139-14AWG; TF-UL3139-12AWG; TF-UL3367-24AWG; TF-UL3367-22AWG; TF-UL3367-20AWG; TF-UL3367-18AWG; TF-UL3367-16AWG; TF-UL3530-18AWG; TF-UL3530-14AWG.
UL 3139 & UL 3367 Reference Standards (UL 758 & ASTM B33)
| Standard or specification | Application |
|---|---|
| UL 758 AWM Style 3139 (600 V, 200 °C, 45-mil Braidless Silicone) | Construction and dimensional design reference for heavy-wall 1.14 mm (45 mils) extruded flame-retardant silicone appliance wire in totally enclosed equipment. |
| UL 758 AWM Style 3367 (300 V, 200 °C, 15-mil Braidless Silicone) | Construction and dimensional design reference for ultra-thin 0.38 mm (15 mils) extruded flame-retardant silicone hook-up wire (24 to 18 AWG). |
| UL 758 AWM Style 3530 (600 V, 200 °C, 30-mil Braidless Silicone) | Medium-wall 0.76 mm (30 mils) 600 V braidless silicone design reference bridging thin-wall Style 3367 and heavy-wall Style 3139. |
| ASTM B33 & CSA C22.2 No. 210 (Class I Group A Reference) | Tin-coated soft or annealed copper wire specification and Canadian internal equipment appliance-wire dimensional reference. Note: TEBAOFLEX holds UL 62 ZJCZ flexible-cord certification (UL-US-2449012-4); Style 3139/3367/3530 wires are supplied as engineered-to-specification OEM constructions without UL Marking. |
Certifications and document support
TEBAOFLEX ISO 9001 quality system and verified certificate scope documentation
UL 758 — Appliance Wiring Material (AWM) Style Construction Framework
ASTM B33 — Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Silicone Hook Up Wire 105–250°C, 300–1000 V UL AWM Styles
A related cable option for a different application or duty profile.
View productFiberglass Braided Silicone Wire — UL 3122, UL 3513, SF-1 & SF-2 / SEW-2 (200 °C)
A related cable option for a different application or duty profile.
View productUL 3123 Silicone Hook-Up Wire, 150°C 600V
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.