DIRECT FACTORY CATALOG · 13 CONSTRUCTIONS

High-Voltage DC, X-Ray & Guarded Test Cables (2 kV – 320 kV DC)

Flexible high-voltage DC single-core, coaxial, guarded triaxial, 75 kV quadraxial, multicore, and 60–320 kV DC X-ray / electron-beam cables engineered with low-partial-discharge semiconductive layers, silicone, FEP, PFA, PEEK, or PE-X dielectrics for NDT, medical/industrial imaging, pulsed-power, and dielectric test benches.

2 kV – 320 kV DCSingle-wire, multicore & 320 kV X-ray / E-beam
Coax · Triax · QuadGuarded low-leakage measurement & semicon screens
MOQ 50 m · 7–45 dSilicone, FEP, PFA, PEEK & XLPE custom builds
TEBAOFLEX 60–320 kV DC X-ray and electron-beam high-voltage cable cutaway with semiconductive layer and tinned copper braid
Construction reference: 60–320 kV DC X-ray & electron-beam cable: multi-element filament/grid cores, HV EPR/semicon barrier & tinned copper braid
Quick try:

MOQ 50 m (standard & custom) · 7–45 working days · Datasheets & drawings on request

Live Product Catalog

Showing 13 of 13 constructions

ENGINEERING QUICK SELECTION

High-Voltage DC & Guarded Test Cable Architecture Comparison

ConfigurationDC Voltage RangeDielectric & Stress ControlShielding GeometryPrimary Test / OEM Equipment
X-Ray & Electron-Beam HV60 kV – 320 kV DCHV EPR + extruded semiconductive layersOverall tinned-Cu braid + protective jacketIndustrial NDT X-ray tubes, CT scanners & E-beam
Quadraxial & Triaxial GuardedUp to 75 kV DCPE-X / FEP low-loss concentric layersDriven guard + outer return + EMI screenFemtoampere leakage, wafer test & hipot benches
HV Coaxial & Multicore3 kV – 60 kV DCPE-X, FEP, PE or silicone multi-coreBraided return screenPulsed power, laser supplies & HV distribution
Semiconductive Silicone Wire15 kV – 100 kV DCSilicone rubber + inner semicon layerUnshielded or shielded flexible leadCorona-suppressed HV modules, electrostatic & lab
PEEK / FEP / PFA HV Wire2 kV – 30 kV DCRadiation/vacuum-grade PEEK or FEP/PFAOptional hybrid screenVacuum chambers, downhole/aerospace test rigs

ENGINEERING GUIDES & SOLUTIONS

Technical Selection Guides & Industry Solutions

MANUFACTURED IN TAICANG, CHINA

Jiangsu Tebaoflex Special Cable — Direct Factory Verification

Founded in 2014 in Taicang, Suzhou (20,000+ m² facility, 12 automated extrusion/braiding/cabling lines, 8 inspection systems, ~150,000 km annual capacity), exporting across 20+ countries. Certified scopes: UL 62 ZJCZ (UL-US-2449012-4), cUL ZJCZ7 (UL-CA-2437036-5), VDE 40060056 (EN 50525-2-21), KC SU01346-25005, and ISO 9001:2015 (244-24-QI-17425-R0-Q, production). Project constructions outside those certified scopes are designed and manufactured to the referenced DIN VDE, IEC, BS, ISO or UL specification.

Taicang extrusion & cabling workshop
Taicang extrusion & cabling workshop
Tinned-copper & aramid anti-torsion braiding
Tinned-copper & aramid anti-torsion braiding
Routine conductor resistance & HV test bench
Routine conductor resistance & HV test bench

PROCUREMENT & TECHNICAL FAQ

Frequently Asked Questions

Why can’t an AC power cable voltage rating be extrapolated directly to 60–320 kV DC test or X-ray service?

DC electric fields distribute across insulation layers according to volume resistivity (which shifts strongly with temperature gradient and space-charge accumulation) rather than permittivity. Dedicated HVDC and X-ray cables use matched semiconductive conductor/insulation screens and high-purity silicone, EPR, PE-X, or fluoropolymer dielectrics to prevent localized corona and premature breakdown.

When should I choose a triaxial or quadraxial HV cable instead of a standard coaxial HV cable?

Standard coaxial HV cable carries high voltage on the center conductor and ground return on the outer braid. Specify triaxial (or 75 kV quadraxial) when performing picoampere/femtoampere leakage measurements, semiconductor wafer probing, or guarded hipot tests where an intermediate driven-guard shield is needed to zero out cable insulation leakage.

Why add an inner semiconductive layer on 15–100 kV DC silicone wires?

Stranded copper conductors create microscopic air gaps at the conductor-insulation interface where intense electric stress triggers partial discharge (corona) above ~10–15 kV DC. An extruded semiconductive silicone layer smooths the conductor contour into an equipotential cylinder, dramatically extending dielectric life.

Do you supply raw bulk HV cable only, or complete terminated HV assemblies?

TEBAOFLEX manufactures bulk high-voltage DC, coaxial, triaxial, quadraxial, and X-ray cables cut to your specified reel or coil lengths (from MOQ 50 m) so OEMs and test labs can terminate with their own Lemo, Alden, Federal/R24, or custom potted HV receptacles.

What are your MOQ and production lead time for custom HVDC constructions?

MOQ is 50 m for both catalog and custom-drawn HVDC / X-ray constructions. Typical factory lead time is 7–45 working days depending on concentric layer count, curing cycle, and dielectric test schedule, confirmed in writing before order.

DIRECT FACTORY ENGINEERING DESK

Request Datasheet, Cross-Reference or Drum Quote

Send your designation, voltage, core × mm²/AWG size, OD limit, or OEM part number. Our engineers confirm construction, MOQ (from 50 m), and production lead time (7–45 working days) in writing.

Helpful details for a faster engineering reply:

  • Continuous & peak DC voltage (kV DC), ripple/pulse waveform, and filament/grid currents (for X-ray / E-beam)
  • Architecture: single-core, coaxial, guarded triaxial, quadraxial, or multi-conductor + semicon screen requirement
  • Dielectric & ambient environment: silicone, PE-X, FEP, PFA, or PEEK (air, transformer oil, vacuum, or radiation)
  • Maximum outer diameter, minimum bend radius on gantry/arm, cut reel lengths (MOQ 50 m) & destination

Selected constructions (auto-filled in form):

  • Tip: Click “+ Add to enquiry” on any catalog card above to attach multiple constructions to your RFQ.

MOQ 50 m (standard & custom) · 7–45 working days lead time · Free technical consultation · Written confirmation before order.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.