Case 20 · Russia · Far East Port (Vladivostok) · Electro-optical MV crane reeling cable
6/10 kV (N)TSCGEWÖU+FO 3×35+2×25/2+(16×2.5)C+24FO Port Crane Reeling Cable Replacement in Vladivostok, Russia
When a port crane maintenance and installation contractor in Vladivostok on Russia's Pacific coast needed to replace aging European-supplied medium-voltage drum cables across two harbor cranes without waiting through extended import lead times, the technical tender locked down every mechanical and electrical boundary: 300 m supplied as exact 125 m and 175 m uncut lengths, 10 kV isolated-neutral port service (Um = 12 kV), 16 screened control cores, 24 integrated optical fibers, a 4.35 kg/m weight ceiling and a 48 to 53 mm finished diameter window. TEBAOFLEX engineered, tested and delivered custom 6/10 kV (N)TSCGEWÖU+FO 3×35+2×25/2+(16×2.5)C+24FO reeling cable measuring 51.69 to 52.54 mm across calipers.

Project at a glance
This Russian Far East port replacement order supplied 300 m of 6/10 kV (N)TSCGEWÖU+FO 3×35+2×25/2+(16×2.5)C+24FO (62.5/125 µm) crane reeling cable in two continuous uncut drum lengths (125 m and 175 m), holding finished outside diameter at 51.69–52.54 mm inside a strict 48–53 mm crane reel groove window.
| Order parameter | Verified project detail |
|---|---|
| Project site & buyer type | Far East sea port in Vladivostok, Russia — harbor crane maintenance and installation contractor |
| Cable designation | 6/10 kV (N)TSCGEWÖU+FO 3×35 + 2×25/2 + (16×2.5)C + 24FO (62.5/125 µm), engineered with reference to DIN VDE 0250-813 |
| Network operating basis | 10 kV nominal 50 Hz isolated-neutral port distribution system; maximum AC system voltage Um = 12 kV |
| Supplied drum lengths | 300 m total split across two continuous uncut wooden export drums: 1 × 125 m and 1 × 175 m (zero splices permitted) |
| Conductor & DC resistance | Class 5 tinned copper (strand wire Ø ≤ 0.26 mm); phase ≤ 0.565 Ω/km and combined earth ≤ 0.795 Ω/km at 20 °C |
| Drum fit & linear mass | Required OD window 48.0–53.0 mm (factory caliper verified 51.69 mm and 52.54 mm); theoretical mass ≤ 4.35 kg/m |
| Dynamic reeling envelope | Travel speed up to 200 m/min; dynamic acceleration pull ≥ 3,150 N; central + braided Kevlar aramid; −30 °C to +80 °C |
| End tails & sheath marking | 2,000 mm breakout allowance on power, control and FO cores; high-contrast sheath print spaced ≤ 1,000 mm (GOST 18690-2012 marking rule) |
How do three 10 kV phases, 16 control cores and 24 fibers fit inside a 48 to 53 mm crane drum groove?
Fitting 3 × 35 mm² 6/10 kV screened power cores, 25 mm² of protective earth, 16 × 2.5 mm² screened control cores and a 24-fiber optical tube below 53 mm requires a two-interstice split-earth layout (2×25/2) so the third outer interstice houses the hybrid control-optical bundle without inflating core pitch diameter.
Replacing a motorized crane drum cable on an existing quay crane is governed by machined steel geometry that cannot be altered on site. On the Vladivostok cranes, if the replacement cable exceeded 53.0 mm outside diameter, adjacent turns would rub drum flanges or climb out of pitch; if it dropped below 48.0 mm, turn-to-turn gaps would let upper layers wedge downward under tension and crush the optical buffer tube. At the same time, crane drive torque capped linear cable mass at 4.35 kg/m.
- 3 × 35 mm² Class 5 tinned copper phase conductors (wire Ø ≤ 0.26 mm, ≤ 0.565 Ω/km at 20 °C), semiconductive screens and 3GI3 EPR dielectric
- 2 × 25/2 mm² (two 12.5 mm² cores = 25 mm² total, ≤ 0.795 Ω/km at 20 °C) semiconductive/EPR split protective-earth conductors
- Aramid (Kevlar) central tensile element isolating axial reeling pull from copper and optical cores
- Screened (16 × 2.5)C tinned-copper 3GI3 control assembly integrated with the 24FO (62.5/125 µm) graded-index multimode optical subunit
- Extruded 5GM3 rubber inner bedding locking the core lay geometry against drum crush
- Open-weave aramid (Kevlar) anti-torsion reinforcing braid vulcanized between inner and outer sheaths
- Cold- and weather-resistant 5GM5 elastomer outer sheath (−30 °C to +80 °C) with ≤ 1,000 mm high-contrast sheath markings
Using a conventional four-core symmetrical layout would have pushed finished diameter past 56 mm. Instead, our engineering team applied the two-split-earth architecture detailed in our fiber-optic composite reeling cable specification guide and (N)TSCGEWÖU and NTSCGEWOU+FO crane reeling cable schedule: splitting the 25 mm² protective earth into two 12.5 mm² semiconductive/EPR conductors (2×25/2) tucked into two outer interstices left the third outer valley free to carry the screened (16×2.5)C control assembly and 24FO subunit.


How were the 62.5/125 µm fiber-mode contradiction and GOST 18690-2012 marking requirement resolved?
Pre-production engineering review caught a translated tender contradiction naming ’24FO (62,5/125) Single mode’—confirming graded-index multimode 62.5/125 µm fibers to match the crane’s rotary joint—and paired DIN VDE 0250-813 reeling construction with GOST 18690-2012 external contrast sheath markings every ≤ 1,000 mm.
Cross-border replacement tenders translated between Russian, German and English frequently mix optical and regulatory terminology. Two technical clarifications prevented costly commissioning mismatches before extrusion started:
- Resolving 62.5/125 µm multimode vs. single-mode wording: Line 5 of the initial English summary wrote
24FO (62,5/125) Single mode, whereas the Russian technical parameter sheet specified 24 integrated multimode fibers. Because a 62.5 µm core / 125 µm cladding geometry is graded-index multimode (OM1) rather than 9/125 µm single-mode—unlike our Vietnam 8.7/15 kV 24FO (9/125 µm) ship-unloader reeling project—confirming24FO GI 62.5/125 µmprevented fatal core-aperture mismatch at the crane’s fiber-optic rotary joint (FORJ). - Aligning DIN VDE 0250-813 construction with GOST 18690-2012 marking rules: Medium-voltage flexible reeling cables with aramid anti-torsion braids follow DIN VDE 0250-813 material and dielectric rules rather than fixed Russian power cable standards. What the port authority's inspection team specifically enforced under GOST 18690-2012 and GOST R 55025-2012 was durable, high-contrast outer-sheath text identifying manufacturer brand and full core designation at equidistant intervals not exceeding 1,000 mm.
- Service-life engineering factors vs. tender reliability targets: Russian port procurement sheets routinely state a 10-year design reliability target in tender boilerplate. Because dynamic reeling life depends on site roller alignment, fleet angle, acceleration tension and ambient ice handling, TEBAOFLEX engineers durability through fine Class 5 tinned stranding (IEC 60228, wire Ø ≤ 0.26 mm), dual Kevlar tensile/anti-torsion reinforcement and −30 °C 5GM5 elastomer compounds rather than stating fixed calendar-year lifespan promises.
Verified electrical, mechanical and dimensional test data
Factory verification confirmed Class 5 tinned-copper DC resistance within ≤ 0.565 Ω/km on the 35 mm² phases and ≤ 0.795 Ω/km on the 2×25/2 split earth at 20 °C, while orthogonal digital caliper checks recorded 51.69 mm and 52.54 mm inside the 48.0–53.0 mm crane drum groove tolerance.
| Parameter | Vladivostok crane tender requirement | Delivered TEBAOFLEX build & verification |
|---|---|---|
| Rated / max system voltage | Uo/U = 6/10 kV; Um = 12 kV (50 Hz isolated-neutral network) | DIN VDE 0250-813 3GI3 EPR screened phase core system (routine 15 kV AC / 5 min test basis) |
| Phase conductors | 3 × 35 mm² Class 5 tinned copper, wire Ø ≤ 0.26 mm, R20 ≤ 0.565 Ω/km | Multi-strand anti-bending tinned copper meeting IEC 60228 / DIN VDE 0295 Class 5 |
| Protective earth | 2 × 25/2 mm² (25 mm² combined) with semiconductive layer, R20 ≤ 0.795 Ω/km | Two symmetrical 12.5 mm² tinned-copper split earth cores freeing the 3rd interstice |
| Control & optical cores | ≥ 16 × 2.5 mm² control + 24 multimode optical fibers | (16 × 2.5)C screened 3GI3 control assembly + 24FO (62.5/125 µm) loose-tube subunit |
| Tensile & anti-torsion members | Kevlar central strength core + Kevlar anti-torsion braid; pull ≥ 3,150 N | Aramid central tension member + vulcanized aramid mesh between 5GM3 and 5GM5 sheaths |
| Outside diameter window | Minimum 48.0 mm · Maximum 53.0 mm | Verified by factory digital calipers at 51.69 mm and 52.54 mm across axes |
| Linear mass & reel speed | ≤ 4.35 kg/m maximum · up to 200 m/min travel speed | Compact 2-split-earth geometry kept below 4.35 kg/m; −30 °C to +80 °C working range |
| Drum lengths & end tails | 125 m + 175 m uncut drums; ≥ 2,000 mm end breakout length | Delivered on two dedicated wooden export drums with sealed ends and ≤ 1,000 mm print spacing |


Holding ovality below 1 mm on a heavy multi-element composite cable prevents periodic twist torque as the cable enters the crane’s level-wind roller cage—the primary mechanical trigger explained in our reeling cable corkscrew failure prevention guide and cable factory acceptance testing checklist.
Why uncut 125 m and 175 m drums and 2,000 mm breakout tails matter at the crane
Delivering exact 125 m and 175 m continuous lengths on separate export drums eliminates crane-side cutting waste, while accounting for 2,000 mm power, control and fiber breakout tails at both ends ensures the active reeling span reaches full quay travel alongside outdoor cold-shrink terminations.
During commercial-technical alignment, the Vladivostok installation contractor also asked whether field-assembled connectors or medium-voltage terminations should be bundled with the cable or sourced locally in Russia. Because harbor crane slip-ring cabinets and quay junction cubicles have fixed bushing spacings and gland threads, our engineers recommended matching 3-core outdoor cold-shrinkable stress-control termination kits to the exact phase insulation diameter while leaving at least 2,000 mm of breakout length on the three 35 mm² power phases, sixteen 2.5 mm² control cores and 24-fiber optical tube at each end.


For ship-to-shore cranes using higher phase cross-sections or single-slot flat monospiral reels instead of round torsional drums, compare our STS crane medium-voltage reeling cable specifications, (N)TSFLCGEWÖU-FO flat medium-voltage optical reeling cable and reeling cable selection guide.
What to send when replacing a Russian or European MV electro-optical crane reeling cable
To engineer a drop-in replacement for an imported DIN VDE 0250-813 electro-optical crane reeling cable, provide the full core and split-earth designation, fiber count and mode (9/125 µm SM vs 50/125 or 62.5/125 µm GI), minimum/maximum drum groove OD, linear weight cap and exact uncut drum lengths.
- System voltage (6/10 kV, 8.7/15 kV or 12/20 kV), neutral earthing mode (such as isolated neutral with Um = 12 kV) and phase/split-earth sizes
- Screened control core count and optical fiber count plus exact mode: single-mode 9/125 µm or graded-index multimode 50/125 µm / 62.5/125 µm
- Existing crane reel groove minimum and maximum permissible outside diameter (mm), maximum kg/m weight, travel speed (m/min) and dynamic pull (N)
- Exact continuous uncut length per drum (including 2,000 mm end breakout tails), minimum winter ambient temperature and sheath marking language/spacing
TEBAOFLEX manufactures custom (N)TSCGEWÖU+FO medium-voltage electro-optical reeling cables in Taicang, Jiangsu (~68 km from Shanghai Port, with overland dispatch to northern ports such as Qingdao available on request) from a 50 m minimum order quantity, with a standard lead time of 7 to 45 working days as of November 2026 depending on configuration and production schedule. Explore crane subsystem routing on our port and container crane cable solutions hub and browse related models under port and festoon cables.
Send your MV +FO crane reel parameters for a replacement quote →
Frequently asked questions on 6/10 kV (N)TSCGEWÖU+FO port crane cables
Why was the 300 m Vladivostok port crane order supplied as 125 m and 175 m drums?
Two harbor cranes at the Russian Far East terminal had fixed active reeling travel spans requiring continuous uncut lengths of 125 m and 175 m respectively. Mid-span splices cannot pass over motorized crane guide sheaves or seat cleanly in drum grooves, so the specification forbade shorter segments and required factory delivery on two dedicated wooden export drums.
How did TEBAOFLEX keep the 6/10 kV hybrid +24FO cable inside the 48 to 53 mm drum groove window?
Placing two 12.5 mm² split earth conductors (2×25/2) into two outer interstices freed the third main interstice for the screened (16×2.5)C control and 24FO subunit without inflating core lay diameter. Factory digital calipers measured 51.69 mm and 52.54 mm across orthogonal axes—squarely inside the 48.0 to 53.0 mm crane reel groove window and under the 4.35 kg/m mass ceiling.
Why did the engineering review clarify 24FO (62.5/125 µm) multimode versus single-mode wording?
Translated tender documents initially wrote ’24FO (62,5/125) Single mode’, combining a 62.5/125 µm graded-index multimode core/cladding dimension with a single-mode label. Pre-production review confirmed the crane’s optical rotary joint and PLC transceivers use 62.5/125 µm graded-index multimode optics, avoiding severe insertion loss at commissioning.
How do DIN VDE 0250-813 and GOST 18690-2012 interact on Russian port crane replacement cables?
Medium-voltage electro-optical crane reeling geometry, 3GI3 EPR dielectric walls, 5GM3/5GM5 double sheathing and 15 kV AC dielectric testing follow DIN VDE 0250-813, whereas Russian port maintenance inspections reference GOST 18690-2012 for external sheath legibility—specifically high-contrast durable text printed at intervals not exceeding 1,000 mm.
What breakout tail length and termination interface are needed on 6/10 kV (N)TSCGEWÖU+FO cables?
Both ends of a hybrid reeling cable must split inside the drum hub and quay junction pit so MV phases land on slip rings or outdoor cold-shrink stress cones while 2.5 mm² control cores and 24 optical fibers route to separate terminal blocks and splice trays. Specifying at least 2,000 mm end breakout allowance prevents shortening the active reeling span.