Case 19 · Venezuela · Underground drill jumbo · 2 kV portable mining cable
Type G-GC 2 kV 3×2 AWG Underground Drill Jumbo Cable for Venezuela: Orange Aramid-Reinforced CPE Build
A mining equipment supply company serving an underground mine in Venezuela ordered 2 kV Type G-GC 3×2+2×7+1×10 AWG power cable to feed multi-boom underground drill jumbos working in confined rock headings. Rather than supplying a standard single-layer black trailing jacket, TEBAOFLEX built the cable to ICEA S-75-381 / NEMA WC 58 with flexible tinned-copper conductors, green EPR-insulated 7 AWG grounds, a yellow 10 AWG ground-check pilot, a black inner bedding, an embedded aramid reinforcing braid and a high-visibility orange extra-heavy-duty CPE outer sheath, measuring 33.65 mm finished outside diameter against the 34.0 mm nominal schedule.

Project at a glance
This order supplied 2,000 V Type G-GC 3×2+2×7+1×10 AWG round portable mining power cable manufactured to ICEA S-75-381 / NEMA WC 58 for an underground drill jumbo in Venezuela, combining 259-strand tinned-copper 2 AWG phase cores, aramid-reinforced double-layer black/orange CPE sheathing, and a caliper-verified 33.65 mm outside diameter.
| Order item | Recorded detail |
|---|---|
| Destination & equipment | Underground mine in Venezuela (via mining supply partner) — multi-boom underground drill jumbo (jumbo driller) feeder and onboard hydraulic reel |
| Cable designation | 2 kV Type G-GC 3 × 2 AWG + 2 × 7 AWG + 1 × 10 AWG, manufactured to ICEA S-75-381 / NEMA WC 58 |
| Phase conductors | 3 × 2 AWG (259 strands) flexible rope-lay tinned copper (ASTM B172 / B33), separator tape, 60 mil (1.52 mm) 90 °C EPR/EPDM insulation (black, white, red) |
| Ground & ground-check cores | 2 × 7 AWG (133 strands) tinned copper with green 90 °C EPR insulation + 1 × 10 AWG tinned copper with yellow 90 °C EPR insulation |
| Sheath & reinforcement | Extruded black thermoset inner sheath + open-weave aramid (Kevlar) reinforcing braid + orange extra-heavy-duty 90 °C CPE outer jacket |
| Outside diameter (nominal vs. measured) | 34.0 mm (1.34 in) datasheet nominal; 33.65 mm (1.325 in) measured on finished cable by digital vernier caliper |
| Ampacity & reel derating | 138 A free in air at 40 °C ambient (152 A at 30 °C NEC ref.); 117 A (1 layer), 90 A (2 layers) or 62 A (3 layers) on jumbo reel |
| Sheath marking | TEBAOFLEX CABLE 2kV TYPE G-GC EPR/CPE ICEA S-75-381 Mining Cable 3X2+2X7+1X10AWG |
Why do underground drill jumbos punish standard trailing cables?
Underground drill jumbos tram through narrow, blasted rock headings to drill blast holes, roof-bolt holes and probe holes, dragging and back-spooling their 2 kV feeder cable under hydraulic reel tension across sharp muck piles, standing mine water and drill-oil mist while sharing single-lane drifts with LHD loaders.
Unlike a stationary substation feeder or a single-plane crane festoon, a drill jumbo cable experiences two mechanical regimes on every shift. While tramming from heading to heading, the onboard hydraulic reel pays out and retrieves the cable under dynamic pull across rock corners; while collared at the face, two or three wraps remain energized on the drum barrel as the electro-hydraulic powerpacks run continuous percussion drilling cycles. How unshielded 2 kV Type G-GC compares against shielded SHD-GC (required above 2 kV or where per-phase electrostatic shielding is mandated) and unmonitored Type W is mapped in our SHD-GC vs Type G-GC vs Type W mining cable comparison, and machine-specific sizing across single-boom and multi-boom rigs is covered on our Type G-GC cable solution for underground drill jumbos page.
What is inside the 2 kV Type G-GC 3×2+2×7+1×10 AWG orange CPE build?
Manufactured to ICEA S-75-381 / NEMA WC 58, the Venezuela build groups three 259-strand 2 AWG tinned-copper phase cores, two green EPR-insulated 7 AWG grounding cores and one yellow EPR-insulated 10 AWG ground-check pilot inside a black inner sheath, an aramid reinforcing braid and an orange extra-heavy-duty 90 °C CPE outer jacket.
- Phase conductors: 3 × 2 AWG (259 strands) flexible rope-lay tinned copper per ASTM B172 / B33 with polyester separator tape
- Phase insulation: 60 mil (1.52 mm) 90 °C heat-, moisture- and oil-resistant EPR/EPDM thermoset (black, white and red)
- Equipment grounding conductors: 2 × 7 AWG (133 strands) flexible tinned copper with green 90 °C EPR insulation
- Ground-check pilot conductor: 1 × 10 AWG flexible tinned copper with yellow 90 °C EPR insulation
- Inner black thermoset bedding + open-weave aramid (Kevlar) anti-tension / anti-torsion reinforcing braid
- High-visibility orange extra-heavy-duty 90 °C thermosetting chlorinated polyethylene (CPE) outer jacket


| Component | Venezuela order construction | Underground drill jumbo engineering purpose |
|---|---|---|
| Phase conductors (3 × 2 AWG) | 259 strands flexible rope-lay tinned copper (ASTM B172 / B33) + polyester separator tape | High flex-fatigue life over hydraulic guide rollers; tin coating blocks copper-sulfur reaction during vulcanization and mine-water corrosion |
| Phase insulation | 60 mil (1.52 mm) 90 °C heat-, moisture- and oil-resistant EPR/EPDM thermoset (black, white, red) | Maintains dielectric strength in wet headings and withstands 90 °C continuous conductor temperature on wound reels |
| Grounding cores (2 × 7 AWG) | 2 × 133-strand flexible tinned copper with separator tape and green 90 °C EPR insulation | Splits fault return symmetrically across two interstices while green EPR blocks corrosive water wicking along ground strands |
| Ground-check core (1 × 10 AWG) | Flexible tinned copper + separator tape + high-strength yellow 90 °C EPR insulation | Completes the pilot continuity loop between the gate-end breaker relay and the jumbo chassis |
| Inner sheath & aramid braid | Black thermoset inner bedding + open-weave aramid (Kevlar) anti-torsion / tensile braid | Locks core lay geometry to resist corkscrewing and absorbs dynamic hydraulic reel tension spikes |
| Outer jacket | Extra-heavy-duty 90 °C thermosetting chlorinated polyethylene (CPE), high-visibility orange | Resists sharp rock cuts, hydraulic percussion oil and abrasion while standing out visually on dark drift floors |
Two details in the dissected sample photograph above deserve close attention when writing underground jumbo specifications. First, the two-colour black-inner / orange-outer wall gives underground electricians an unambiguous wear gauge: as long as only orange CPE shows, full inner mechanical containment remains intact, whereas exposed black inner rubber or white aramid yarn signals scheduled replacement before a phase fault occurs—a thermoset advantage explained in our thermoset rubber and CPE vs thermoplastic TPE cable guide. Second, the 10 AWG yellow pilot conductor works with gate-end ground-check relays (as required in North American practice under 30 CFR Part 75 Subpart I) to trip power if earth continuity opens; field relay diagnostics are detailed in our mining trailing cable ground-check trip troubleshooting guide.
How do multi-layer reel derating and the 33.65 mm measured OD fit the jumbo drum?
Per the TEBAOFLEX 2 kV Type G-GC datasheet to ICEA S-75-381 / NEMA WC 58, 3/C 2 AWG carries 138 A in free air at 40 °C ambient (90 A with two layers left on the jumbo reel, or 62 A with three layers), while the finished cable measured 33.65 mm on a digital caliper against the 34.0 mm nominal diameter.
| Operating / dimensional parameter | Datasheet nominal (3/C 2 AWG) | Venezuela order value / reel rating | Engineering basis & verification note |
|---|---|---|---|
| Outside diameter (OD) | 34.0 mm (1.34 in) | 33.65 mm (1.325 in) measured | Digital vernier caliper check (−0.35 mm / −1.0 % from nominal; fits 34 mm level-wind guides and glands) |
| Approximate cable weight | 2,202 kg/km (1,480 lb/kft) | Nominal 3/C 2 AWG class | Used to verify hydraulic reel torque and drum flange payload |
| Free-air ampacity (40 °C ambient) | 138 A | 138 A (fully paid out) | 90 °C conductor temperature, TEBAOFLEX 2 kV Type G-GC schedule |
| Free-air ampacity (30 °C NEC ref.) | 152 A | 152 A (catalogue comparison) | NEC Table 400.5(A)(2) 30 °C ambient code-table reference |
| Jumbo reel — 1 wound layer (× 0.85) | 117 A | 117 A continuous | 138 A × 0.85 single-layer drum ventilation factor |
| Jumbo reel — 2 wound layers (× 0.65) | 90 A | 90 A continuous | 138 A × 0.65 two-layer drum factor (typical face-drilling condition) |
| Jumbo reel — 3 wound layers (× 0.45) | 62 A | 62 A continuous | 138 A × 0.45 three-layer drum factor; pay out extra wraps if load exceeds 62 A |
| Jumbo reel — 4 wound layers (× 0.35) | 48 A | 48 A continuous | 138 A × 0.35 four-layer drum factor; avoid high-load drilling with 4+ layers |


Full stranding, insulation wall and weight schedules from 8 AWG through 500 kcmil are published on our Type G-GC 2,000 V portable mining power cable datasheet, manufactured to ICEA S-75-381 / NEMA WC 58. TEBAOFLEX has also carried out temperature-rise testing on this Type G-GC construction. Even with 90 °C EPR insulation, leaving three or four tightly wound layers energized on an unventilated drill jumbo drum during multi-boom percussion drilling traps heat inside the inner wraps—how to recognize thermal hardening and splice limits before jacket failure is covered in our trailing cable reel overheating and mechanical damage guide.
Sheath marking and single-piece factory drum winding
Each metre of the finished orange CPE jacket carries durable contrast ink marking identifying TEBAOFLEX CABLE, 2 kV Type G-GC, EPR/CPE compounds, ICEA S-75-381 and 3X2+2X7+1X10AWG, wound onto steel-braced plywood export drums for sea transit to South America.
TEBAOFLEX CABLE 2kV TYPE G-GC EPR/CPE ICEA S-75-381 Mining Cable 3X2+2X7+1X10AWG


Clear contrast legibility on an orange jacket lets underground electrical inspectors verify voltage grade, standard basis and pilot-core presence at a glance without scraping mud off black rubber embossing. For a larger-cross-section Latin American feeder supply in the same ICEA S-75-381 family, compare our 3×4/0 AWG Type G-GC portable mining cable project in Mexico.
What to specify when ordering Type G-GC drill jumbo cable
Sending your drill jumbo model or total kW load, operating system voltage, phase and ground/pilot AWG configuration, hydraulic reel barrel diameter and maximum wound layers, preferred CPE jacket colour (orange, yellow or black) and required cut lengths enables a complete engineering check before production.
- Conductor configuration: e.g. 3 × 2 AWG + 2 × 7 AWG + 1 × 10 AWG (or 4 AWG, 1/0 AWG, 2/0 AWG, 4/0 AWG per jumbo load)
- Operating voltage, mine ambient temperature and maximum number of cable layers kept wound on the jumbo drum while drilling
- Grounding core preference: green EPR-insulated grounding conductors (recommended for wet underground headings) vs uninsulated grounds
- Sheath structure and colour: high-visibility orange, yellow or standard black thermosetting CPE, with aramid reinforcing braid
- Continuous drum length per jumbo, gland/coupler entry diameter window, sheath marking text and destination port
TEBAOFLEX manufactures custom and standard 2 kV Type G-GC mining cables from a 50 m minimum order quantity (MOQ), with a standard production lead time of 7 to 45 working days as of November 2026 depending on custom jacket tooling and order volume. Browse all North American, DIN VDE, BS and AS/NZS underground constructions in our mining, drilling and tunnelling cables catalogue.
Send your drill jumbo cable specification for an engineering quote →
Frequently asked questions on 2 kV Type G-GC 3×2 AWG drill jumbo cable
Why is 2 kV Type G-GC 3×2 AWG specified for underground drill jumbos?
Multi-boom underground drill jumbos operate on low-voltage three-phase mine feeders (typically 440 V to 1,000 V AC) inside wet, confined rock headings where ground-continuity monitoring is mandatory. Under ICEA S-75-381 / NEMA WC 58, 2 kV Type G-GC 3×2+2×7+1×10 AWG combines 138 A free-air phase capacity (at 40 °C ambient), symmetrical 2 × 7 AWG equipment grounds and a dedicated 10 AWG yellow ground-check pilot core in a compact 34.0 mm nominal diameter that spools cleanly onto the jumbo’s rear hydraulic cable reel.
Why did this Venezuela drill jumbo order use an orange CPE outer jacket over a black inner sheath?
Standard catalogue Type G-GC cables use a black CPE jacket, which blends into wet, unlit dark rock floors in underground drifts and increases run-over risk from LHD loaders and utility trucks. Extruding a high-visibility orange extra-heavy-duty CPE outer sheath over a black thermoset inner bedding and aramid braid makes the cable visible under cap lamps and vehicle headlights while giving maintenance crews an immediate visual wear indicator if rock abrasion cuts through the outer layer.
How much current can Type G-GC 3×2 AWG carry when wound on a drill jumbo cable reel?
The TEBAOFLEX 2 kV Type G-GC datasheet rates 3/C 2 AWG at 138 A in free air at 40 °C ambient with a 90 °C conductor temperature (152 A at 30 °C NEC Table 400.5(A)(2) reference). When wound on the drill jumbo’s cable drum during face drilling, apply the multi-layer reel multiplying factors: 0.85 for 1 wound layer (117 A), 0.65 for 2 layers (90 A), 0.45 for 3 layers (62 A) and 0.35 for 4 layers (48 A).
Why are the two 7 AWG grounding conductors insulated in green EPR on this construction?
While some surface Type G-GC builds leave interstitial grounding wires uninsulated beneath separator tape, underground headings with acidic or mineral-laden mine water can wick moisture along bare strands. Insulating both 7 AWG tinned-copper grounding conductors in green 90 °C EPR—alongside the yellow 10 AWG ground-check core—protects strand integrity and simplifies clean core routing inside tight flameproof or watertight jumbo coupler housings.
What standards apply to TEBAOFLEX 2 kV Type G-GC 3×2+2×7+1×10 AWG cable?
This construction is engineered and manufactured to ICEA S-75-381 / NEMA WC 58, with ASTM B172 and ASTM B33 flexible tinned-copper rope-lay conductors and CAN/CSA C22.2 No. 96 portable power cable design reference. Minimum order quantity is 50 m and standard manufacturing lead time is 7 to 45 working days; state any mine-specific documentation or jacket-marking requirements with your inquiry so our engineering team can confirm them before order release.