Submersible Pump Cables TEBAOFLEX

Flat Submersible Pump Cable 3 x 6 + 1 x 6 AWG

Flat submersible pump cable, 600/2000 V, EPR 90 °C / CPE, three phase conductors and one insulated grounding conductor laid flat under a blue jacket.

  • Lead build: 3 x 6 AWG + 1 x 6 AWG, full-size ground.
  • Range: 6 AWG to 500 kcmil, with AWG and mm² shown for every size.
  • Construction basis: UL 44 Section 7 deep-well pump cable; ICEA S-75-381 / NEMA WC 58 jacket and ampacity basis.
  • Supply: 300 m reels, custom print legend; UL and MSHA approval details with the quotation.
Product information
Brand
TEBAOFLEX
Product overview

Flat Submersible Pump Cable with Full-Size Ground

This flat submersible pump cable carries three EPR-insulated phase conductors and one insulated grounding conductor side by side under a single blue CPE jacket. It powers deep-well submersible pumps, fixed mine dewatering pumps and other submerged equipment, and it is built to the construction of a UL 44 Section 7 deep-well submersible water-pump cable, with the jacket and ampacity basis of ICEA S-75-381 / NEMA WC 58.

The lead build is 3 x 6 AWG + 1 x 6 AWG: the grounding conductor is the same size as the phase conductors. UL 44 only sets a minimum ground size, and for 6 AWG phases that minimum is 8 AWG, so a full-size 6 AWG ground carries a clear margin for fault current and for long drop lengths. We supplied this build to a project in Peru.

The conductors are uncoated annealed copper in fine rope-lay stranding, with a separator tape under 90 °C EPR insulation. The heavy-duty thermoset CPE jacket resists water, oil, ozone, sunlight and flame, and it stays flexible from −40 °C. The flat profile keeps the cable close to the drop pipe inside the well casing.

The range runs from 6 AWG to 500 kcmil, 600/2000 V, on 300 m reels, with blue as the standard jacket colour and a print legend made to your order. UL and MSHA approval details for this construction are provided with the quotation.

Construction

Flat Submersible Pump Cable Construction

Flat submersible pump cable cross-section: four equal EPR-insulated copper cores in a row inside a blue CPE jacket
Four equal cores in one flat row: black, red and yellow phases and a green/yellow full-size grounding conductor, each with its separator tape, inside the blue CPE jacket.
Construction from the conductor outwards
ElementConstructionReference
ConductorsUncoated (untinned) annealed copper, fine rope-lay flexible strandingASTM B3; ASTM B172
SeparatorTape between each conductor and its insulationRequired with uncoated copper under UL 44
InsulationEthylene propylene rubber (EPR), 90 °C; rubberised tape over each phase coreUL 44
Phase identificationBlack, red, yellow-
Grounding conductorInsulated, green/yellow, same insulation type as the phase coresUL 44 Section 7
AssemblyThree phase cores and the grounding conductor laid parallel in one flat row, bonded by the jacket-
JacketHeavy-duty thermoset chlorinated polyethylene (CPE), blue as standard, other colours on requestICEA S-75-381 / NEMA WC 58, clause 3.21 (jackets)

Why the lead build has a full-size ground

UL 44 treats the grounding conductor in a deep-well pump cable as optional, but where one is fitted it must be insulated, of the same insulation type as the phase conductors, and not smaller than the size UL 44 Table 35.1 sets for the phase size. For 6 AWG phases that minimum is 8 AWG. The 3 x 6 AWG + 1 x 6 AWG build goes one step further and makes the ground the same size as the phases. That is the arrangement to specify when the pump motor sits at the end of a long drop, when the protective device needs a low-impedance fault path to clear quickly, or when the project standard simply asks for a full-size ground. Larger sizes in the table carry the standard grounding conductors listed; a full-size ground can be built on request for any of them.

Why flat, and why EPR and CPE

Laying the four cores in one row keeps the cable thin in one direction, so it sits close to the drop pipe and takes less of the annular space inside the well casing than a round cable of the same size. The EPR insulation is rated for a 90 °C conductor, and the thermoset CPE jacket does not soften with heat the way thermoplastic jackets do.

EPR/CPE rubber pump cable against typical PVC submersible pump wire
PropertyThis cable (EPR / CPE)Typical PVC or PE pump cable
Conductor temperature rating90 °CUsually 75 °C
6 AWG copper ampacity, NEC Table 310.1675 A in the 90 °C column65 A in the 75 °C column
Insulation and jacket typeThermoset rubber: does not melt or flow with heatThermoplastic: softens as temperature rises
Cold-weather handlingRated from −40 °CStiffens at low temperature; check the rated minimum
Oil and hydrocarbonsCPE jacket is oil resistantDepends on the compound
Grounding conductorInsulated, full size on the lead buildOften reduced, sometimes bare, sometimes absent

The cable is a UL 44 Section 7 deep-well submersible water-pump cable. UL 44 assigns no type letters to that class, and the construction is neither an ICEA Type W cable, which has no grounding conductor, nor an ICEA flat Type G cable, which has two. For a flat cable that travels with mobile equipment instead of hanging in a well, see our four-conductor flat Type W mining cable.

Applications

Applications and Installation

Blue flat submersible pump cable strapped to a steel riser pipe, entering a borehole wellhead through a cable gland
The flat cable pays off the reel and runs down the borehole strapped to the riser pipe, so the pipe carries its weight.
  • Deep-well submersible water pumps for municipal, agricultural and industrial supply.
  • Fixed mine dewatering installations - boreholes, shaft pumps and fixed sumps - where the CPE jacket's oil resistance and the full-size ground matter.
  • Submersible motors and other electrical equipment installed in water and left in place.

A pump that is lifted, dragged or reeled in and out regularly needs a portable cable instead: see our four-conductor flat Type W mining cable for that duty.

UL 44 describes this class of cable as intended for use within the well casing to wire deep-well water pumps, where the cable is not subject to repetitive handling. It is designed for continuous immersion in wells up to 500 m deep; the suspension method, splices and terminations are confirmed for each project, because they, not the jacket, usually decide how deep a string can go. A cable that is reeled in and out or dragged with a machine belongs to the portable cable family instead.

Installation practice

  • Pay the cable off the reel in a straight line without twisting it; a flat cable should never be pulled off over the reel flange.
  • Strap it to the drop pipe at the intervals the pump manufacturer specifies, so the pipe, not the splices or the motor leads, carries the cable's weight. The table weights multiplied by the setting depth give that hanging load; for the 3 x 6 + 1 x 6 AWG build, use the weight confirmed on the order drawing.
  • Keep pulling loads below the maximum pulling tension listed for the size.
  • Join the cable to the motor leads with a splice kit rated for continuous submersion, and test the insulation resistance before the string is lowered and again after splicing.
  • For a pump motor on a variable-frequency drive, confirm the maximum cable length and any output filtering with the drive manufacturer. Long unfiltered drive outputs produce voltage peaks well above the supply voltage, and the drive and pump manufacturers set the filter and cable-length limits.

Reference: Peru project

The 3 x 6 AWG + 1 x 6 AWG build with a blue CPE jacket was supplied to a project in Peru.

What to send with an enquiry

  • Phase size, and whether the ground should be the standard size or full size.
  • System voltage, motor power and full-load current.
  • Setting depth plus the horizontal run from the wellhead to the control panel.
  • Casing inside diameter and drop pipe size, so the flat width can be checked for clearance.
  • Water temperature and any oil, hydrocarbon or mine-water exposure.
  • Starting method: across the line, soft starter or variable-frequency drive.
  • Reel length or continuous lengths per well, print legend and destination port.

Buyer questions

What does 3 x 6 + 1 x 6 AWG mean?

Three 6 AWG phase conductors plus one 6 AWG grounding conductor. The second figure is the ground size, so 3 x 6 + 1 x 6 AWG has a full-size ground, while a label such as 3 x 6 AWG + 8 AWG means a reduced ground: 8 AWG is the smallest grounding conductor UL 44 allows with 6 AWG phases.

Does a submersible pump cable need a full-size ground?

Not by UL 44, which sets a minimum: 8 AWG for 6 AWG phases. A full-size ground is chosen when the drop is long, when the protective device needs a low-impedance fault path to clear a fault quickly, or when the project standard requires it. The lead build on this page has one.

What does 600/2000 V mean on this cable?

It is a dual marking. 600 V is the rating under UL 44, which this insulation thickness meets. 2000 V is the class of ICEA S-75-381 / NEMA WC 58 portable power cable, which covers constructions rated 2,000 volts or less. The quotation confirms which rating applies to your installation.

How many amps can 6 AWG submersible pump cable carry?

87 A at 30 °C ambient and 79 A at 40 °C ambient, for three loaded conductors at a 90 °C conductor temperature in free air; the bases are NEC Table 400.5(A)(2) and ICEA S-75-381 Table H-1. Where the authority having jurisdiction applies NEC Table 310.16 instead, the figure is 75 A. Derate for cable on a reel, bundled, or in warm water.

Flat or round submersible pump cable: which is better?

For a cable that hangs in a well and stays there, flat is the usual choice. It is thinner in one direction, so it leaves more clearance in the casing and straps flat against the drop pipe. Round cable resists twisting better where the cable is handled repeatedly.

Can PVC submersible pump wire be used instead?

Yes, for small pumps in cool, clean water. PVC submersible pump wire is usually rated for a 75 °C conductor, so the same size carries less current - 65 A against 75 A at 6 AWG in NEC Table 310.16 - and thermoplastic softens with heat. EPR/CPE is the choice for larger motors, hot or oily water, mine dewatering and cold surface runs.

How deep can the cable be installed?

It is designed for continuous immersion in wells up to 500 m deep. The practical limit is usually set by how the string is supported, the splices and the terminations, so the setting depth is confirmed with the quotation.

How is it delivered?

On 300 m (984 ft) reels as standard, with blue as the standard jacket colour and a print legend made to your specification. Continuous lengths matched to each well can be supplied so that there is no intermediate splice in the drop.

Related cables

For pump-set selection across voltages see our submersible pump motor cable overview. For potable-water wells built to European standards see Drincable 600 potable water pump cable and the H07RN8-F submersible pump cable. Mining-cable catalogue names from other manufacturers are mapped in our mining cable designation cross-reference.

Reference note: enquiries arriving marked AQUAFLEX or HYDROFLEX for a flat EPR/CPE pump cable are handled on this page.

Trademark note: AQUAFLEX® and HYDROFLEX® are trademarks of their respective owners, and TEBAOFLEX is neither affiliated with those companies nor reselling their cable. We manufacture this flat EPR/CPE pump cable to the UL 44 and ICEA S-75-381 construction basis described on this page, and every size listed here can be quoted and supplied as a TEBAOFLEX build. Where a specification names another manufacturer's product, send it with the enquiry and the construction is compared parameter by parameter before anything is offered against it.

Specifications

Flat Submersible Pump Cable Specifications

Voltage marking600/2000 V (600 V under UL 44; 2000 V class under ICEA S-75-381 / NEMA WC 58)
Conductor temperature90 °C
Operating temperature range−40 °C to +90 °C
ImmersionDesigned for continuous immersion in wells up to 500 m deep
Jacket colourBlue as standard; other colours on request
Print legendMade to the customer's specification
Standard packaging300 m (984 ft) reels; other lengths on request
ApprovalsUL and MSHA approval details for this construction are provided with the quotation

Sizes and technical data

The first column carries the full size so that each row can be read on its own: phase conductors first, grounding conductor second. The 3 x 6 AWG + 1 x 6 AWG build has a full-size ground, so its thickness, width and weight are custom and are confirmed on the order drawing.

Flat submersible pump cable, 600/2000 V, EPR/CPE: sizes and data
Size, phases + groundPhase conductorStranding (no. × dia.)Insulation, nominalJacket, nominalThickness × widthWeight approx.Ampacity, 40 °C ambientAmpacity, 30 °C ambientMax. pulling tensionInductance
Flat submersible pump cable 3 x 6 AWG + 1 x 6 AWG13.3 mm²264 × 0.254 mm0.060 in
1.52 mm
3.18 mmCustomCustom79 A87 A600 N0.343 mH/km
Flat submersible pump cable 3 x 4 AWG + 1 x 6 AWG21.2 mm²418 × 0.254 mm0.060 in
1.52 mm
3.56 mm0.67 × 1.83 in
16.9 × 46.4 mm
1616 kg/km
1086 lb/1000 ft
104 A114 A950 N0.328 mH/km
Flat submersible pump cable 3 x 2 AWG + 1 x 5 AWG33.6 mm²660 × 0.254 mm0.060 in
1.52 mm
3.94 mm0.76 × 2.10 in
19.2 × 53.3 mm
2328 kg/km
1564 lb/1000 ft
138 A152 A1500 N0.323 mH/km
Flat submersible pump cable 3 x 1 AWG + 1 x 4 AWG42.4 mm²836 × 0.254 mm0.080 in
2.03 mm
3.94 mm0.85 × 2.45 in
21.5 × 62.2 mm
2872 kg/km
1930 lb/1000 ft
161 A177 A1900 N0.320 mH/km
Flat submersible pump cable 3 x 1/0 AWG + 1 x 3 AWG53.5 mm²1056 × 0.254 mm0.080 in
2.03 mm
4.32 mm0.92 × 2.65 in
23.3 × 67.2 mm
3552 kg/km
2387 lb/1000 ft
186 A205 A2400 N0.318 mH/km
Flat submersible pump cable 3 x 2/0 AWG + 1 x 2 AWG67.4 mm²1320 × 0.254 mm0.080 in
2.03 mm
4.32 mm0.96 × 2.83 in
24.4 × 71.8 mm
4064 kg/km
2731 lb/1000 ft
215 A237 A3000 N0.305 mH/km
Flat submersible pump cable 3 x 3/0 AWG + 1 x 1 AWG85.0 mm²1672 × 0.254 mm0.080 in
2.03 mm
4.83 mm1.07 × 3.13 in
27.1 × 79.6 mm
5051 kg/km
3394 lb/1000 ft
249 A274 A3825 N0.297 mH/km
Flat submersible pump cable 3 x 4/0 AWG + 1 x 1/0 AWG107.2 mm²2090 × 0.254 mm0.080 in
2.03 mm
4.83 mm1.11 × 3.32 in
28.3 × 84.4 mm
6064 kg/km
4075 lb/1000 ft
287 A316 A4800 N0.292 mH/km
Flat submersible pump cable 3 x 250 kcmil + 1 x 2/0 AWG126.7 mm²2496 × 0.254 mm0.095 in
2.41 mm
5.21 mm1.22 × 3.66 in
31.1 × 92.9 mm
7148 kg/km
4803 lb/1000 ft
320 A352 A5800 N0.289 mH/km
Flat submersible pump cable 3 x 350 kcmil + 1 x 3/0 AWG177.3 mm²3416 × 0.254 mm0.095 in
2.41 mm
5.59 mm1.36 × 4.14 in
34.6 × 105.1 mm
9532 kg/km
6405 lb/1000 ft
394 A433 A7900 N0.287 mH/km
Flat submersible pump cable 3 x 400 kcmil + 1 x 4/0 AWG202.7 mm²3904 × 0.254 mm0.095 in
2.41 mm
5.59 mm1.41 × 4.33 in
35.9 × 110.1 mm
10404 kg/km
6991 lb/1000 ft
430 A468 A9100 N0.285 mH/km
Flat submersible pump cable 3 x 500 kcmil + 1 x 250 kcmil253.4 mm²4880 × 0.254 mm0.095 in
2.41 mm
6.35 mm1.61 × 4.93 in
40.9 × 125.3 mm
14141 kg/km
9502 lb/1000 ft
487 A536 A11400 N0.278 mH/km

The last column is inductance, not reactance. At 60 Hz the reactance is 2πfL, so 0.343 mH/km at 6 AWG is about 0.129 Ω/km, and 0.278 mH/km at 500 kcmil is about 0.105 Ω/km.

Ampacities are for three current-carrying conductors at a 90 °C conductor temperature, for a single cable in free air. The 40 °C column follows ICEA S-75-381 / NEMA WC 58 Annex H, Table H-1. The 30 °C column follows NEC Table 400.5(A)(2), 90 °C, column F; at 400 kcmil the NEC value is 468 A, which is why that row does not scale exactly with the ICEA figure. Derate for cable left on a reel, bundled, enclosed, or run in warm water or air.

Where the authority having jurisdiction applies NEC Table 310.16

A UL 44 pump cable is built from conductor types covered by NEC Article 310, so the authority having jurisdiction may assess it on Table 310.16 rather than Table 400.5(A)(2). The lower values below then apply; state the basis your project requires in the enquiry.

NEC Table 310.16 alternative basis (90 °C copper, 30 °C ambient)
Phase conductorAmpacity
6 AWG copper, 90 °C column75 A
4 AWG copper, 90 °C column95 A
2 AWG copper, 90 °C column130 A
1 AWG copper, 90 °C column145 A
1/0 AWG copper, 90 °C column170 A
2/0 AWG copper, 90 °C column195 A
3/0 AWG copper, 90 °C column225 A
4/0 AWG copper, 90 °C column260 A
250 kcmil copper, 90 °C column290 A
350 kcmil copper, 90 °C column350 A
400 kcmil copper, 90 °C column380 A
500 kcmil copper, 90 °C column430 A

Voltage drop: a worked example

Voltage drop on a three-phase run is √3 × current × conductor resistance × length. Take a 30 hp, 460 V three-phase pump motor, whose full-load current in NEC Table 430.250 is 40 A, on 6 AWG. NEC Chapter 9, Table 8 gives 0.491 Ω per 1000 ft (1.61 Ω/km) for stranded uncoated copper at 75 °C, so each metre drops 1.732 × 40 × 0.00161 = 0.11 V. A 3 % limit, 13.8 V, is reached at about 124 m (about 406 ft) of cable, counting the drop and the horizontal run together. Fine flexible stranding runs slightly above that tabulated resistance, so treat the figure as an upper bound and check it against the pump manufacturer's cable-length tables, which also allow for motor starting.

Weight per standard reel

Cable weight on a standard 300 m (984 ft) reel, excluding the reel
Size, phases + groundCable weight per 300 mCable weight per 984 ft
Flat submersible pump cable 3 x 6 AWG + 1 x 6 AWGCustomCustom
Flat submersible pump cable 3 x 4 AWG + 1 x 6 AWG485 kg1069 lb
Flat submersible pump cable 3 x 2 AWG + 1 x 5 AWG698 kg1540 lb
Flat submersible pump cable 3 x 1 AWG + 1 x 4 AWG862 kg1900 lb
Flat submersible pump cable 3 x 1/0 AWG + 1 x 3 AWG1066 kg2349 lb
Flat submersible pump cable 3 x 2/0 AWG + 1 x 2 AWG1219 kg2688 lb
Flat submersible pump cable 3 x 3/0 AWG + 1 x 1 AWG1515 kg3341 lb
Flat submersible pump cable 3 x 4/0 AWG + 1 x 1/0 AWG1819 kg4011 lb
Flat submersible pump cable 3 x 250 kcmil + 1 x 2/0 AWG2144 kg4728 lb
Flat submersible pump cable 3 x 350 kcmil + 1 x 3/0 AWG2860 kg6304 lb
Flat submersible pump cable 3 x 400 kcmil + 1 x 4/0 AWG3121 kg6881 lb
Flat submersible pump cable 3 x 500 kcmil + 1 x 250 kcmil4242 kg9353 lb
Standards

Standards and Approvals

ReferenceWhat it covers for this cable
UL 44, Section 7Deep-well submersible water-pump cable construction; insulation and grounding-conductor requirements; the 600 V rating
UL 44, Table 35.1Minimum grounding-conductor size for each phase size; the full-size ground on the lead build exceeds it
ICEA S-75-381 / NEMA WC 58Clause 3.21 jacket requirements; the 2,000-volts-or-less portable power cable class; Annex H ampacity basis
ASTM B3Soft or annealed copper wire
ASTM B172Rope-lay stranded copper conductors for flexible cable
NEC Table 400.5(A)(2)30 °C ambient ampacity basis, three current-carrying conductors
NEC Table 310.15(B)(1)(1) and Table 310.16Ambient correction factors, and the alternative Article 310 ampacity basis

UL and MSHA approval details for this construction are provided with the quotation, and routine test reports are supplied with the order documents. The standards above describe the construction and the rating basis; if a project needs a particular listing marked on the cable, state it in the enquiry and we will confirm what is supplied.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.