Type PG & Type PCG 600/2000 V Portable Mining Power & Control Cable (2/C & 3/C, 8 AWG–500 kcmil)
Type PG & Type PCG 600/2000 V Portable Mining Cable delivers unshielded heavy-duty power, grounding and integrated pilot/control circuits from 8 AWG to 500 kcmil in accordance with ICEA S-75-381 / NEMA WC 58. Built with ASTM B172 and ASTM B33 rope-lay tinned copper conductors, 90 °C EPR insulation and reinforced thermoset CPE or optional TPU outer jackets, Type PG incorporates one bare grounding core while Type PCG adds two insulated control conductors.
Type PG & Type PCG 600/2000 V Portable Mining Power and Control Cable fills the specialized ICEA S-75-381 / NEMA WC 58 slot between standard 2-ground Type G-GC trailing cables and individually phase-shielded Type SHD-PCG cables, spanning 8 AWG through 500 kcmil (O.D. 23.1 mm to 74.2 mm, +40 °C free-air ampacity 72 A to 536 A).
On underground continuous miners, roof bolters, stage loaders, feeder-breakers and face dewatering skids, machine contactors frequently require two dedicated control or interlock conductors alongside three-phase 480 V, 600 V or 995 V power without the stiffer bend radius of metallic phase shields. Type PG arranges two or three rope-lay tinned-copper power cores with one uninsulated stranded copper equipment ground for compact O.D. on unmonitored circuits, whereas Type PCG places one uninsulated ground in one valley and two color-coded EPR-insulated control conductors (12 AWG, 10 AWG or heavy-duty 8 AWG) in the remaining two valleys—keeping the cabled core perfectly round beneath a cord-reinforced thermoset CPE (or optional abrasion-grade TPU) outer sheath.
Specify Type PG when a compact 2/C or 3/C + single-ground 2 kV portable cable is required without pilot cores; specify Type PCG when your 600–2000 V machine needs two integral remote-control or ground-check wires; choose Type G-GC for symmetrical twin-ground + single ground-check service, or step up to Type SHD-PCG where individual phase shielding is mandated above 2 kV. Minimum order quantity 50 m; manufacturing lead time 7 to 45 working days.
Explore the mining and tunneling cable range for related configurations.
Type PG & Type PCG 600/2000 V Cable Construction
Engineered in accordance with ICEA S-75-381 / NEMA WC 58 and CAN/CSA C22.2 No. 96 dimensional rules for 600/2000 V extra-hard-usage underground and surface mining equipment.

| Component | Material and construction |
|---|---|
| 1. Phase Power Conductors (2/C or 3/C) | Flexible rope-lay bunched or concentric stranded annealed tinned copper per ASTM B33 and ASTM B172 (8 AWG through 500 kcmil; bare copper optional). |
| 2. Phase Insulation (90 °C EPR) | Heavy-duty thermosetting Ethylene Propylene Rubber (EPR) rated +90 °C continuous, color-coded Black/White (2/C) or Black/White/Red (3/C) over polyester separator tape. |
| 3. Equipment Grounding Conductor (1 × Bare Tinned Cu) | One flexible rope-stranded uninsulated tinned copper grounding conductor sized to ICEA S-75-381 Table 3-25 (10 AWG up to 4/0 AWG) laid in intimate valley contact. |
| 4. Control / Pilot Conductors (Type PCG Only — 2 × Insulated) | Two flexible tinned copper control/pilot conductors (12 AWG, 10 AWG or reinforced 8 AWG) insulated with 90 °C yellow and blue EPR in the remaining two interstices. |
| 5. Reinforcing Binder & Heavy-Duty Outer Jacket | Open-weave synthetic reinforcing cord/tape bonded into a mold-cured two-layer extra-heavy-duty black Chlorinated Polyethylene (CPE) jacket (optional CSP/PCP or EHD TPU). |
Type PG & Type PCG ICEA S-75-381 Code Breakdown
- P (Power Conductors): Two or three 600/2000 V insulated flexible copper phase conductors carrying machine motor load
- C (Control Conductors — PCG): Two integral insulated control/pilot conductors enabling remote contactor start-stop interlock and ground-continuity monitoring
- G (Grounding Conductor): Single uninsulated flexible tinned-copper equipment grounding conductor laid in the cabled interstice
- 600/2000 V Rating: ICEA S-75-381 dielectric wall schedule supporting 480 V, 600 V, 995 V AC and 300/600 V DC mobile mining machinery
- EPR / CPE (or TPU): 90 °C thermoset EPR primary insulation paired with oil-, acid- and flame-resistant CPE or high-tear polyurethane outer sheathing
Type PG & Type PCG Underground & Surface Mining Applications
Built for mobile and semi-mobile low-voltage mining equipment requiring compact grounding or dual integrated pilot/control circuits.

- Underground continuous miners, coal cutters, roof bolters, feeder-breakers and armored face conveyor (AFC) stage loaders operating at 480 V, 600 V or 995 V AC.
- Remote-interlocked mine dewatering pump skids, auxiliary ventilation fans and portable power-center branch drops using Type PCG's two built-in control cores.
- DC haulage motors, battery charging stations and twin-pole 2/C Type PG / Type PCG portable power feeds in potash, trona, salt and hard-rock mines.
- Quarry crushers, screening decks and tunnel-boring slurry booster pumps exposed to wet rock abrasion, hydraulic oil and impact.
- Custom reel lengths starting at 50 m MOQ (7 to 45 working days) with optional tinned-copper conductors and yellow/orange TPU jacket upgrades.
Type PG & Type PCG vs. Type G-GC & Type SHD-PCG Selection Matrix
| Designation | Ground & Pilot Layout | Phase Shielding | Primary Mine Equipment Duty |
|---|---|---|---|
| Type PG (this page) | 1 bare ground, 0 pilot/control | Unshielded (600/2000 V) | Compact 2/C or 3/C mobile feeders, pumps & DC skids without ground-check loop |
| Type PCG (this page) | 1 bare ground + 2 insulated control cores | Unshielded (600/2000 V) | Continuous miners, bolters & stage loaders needing start/stop interlock + pilot |
| Type G-GC (WC 1391) | 2 symmetrical grounds + 1 ground-check | Unshielded (2000 V) | Standard AC jumbos, shuttle cars & power-center drops with 1 pilot monitor |
| Type SHD-PCG (WC 3662) | 2 grounds + control group | Individually copper-braid shielded | 995 V–5 kV shearers & continuous miners requiring per-phase fault containment |
Always verify coupler pin count and pilot-relay circuit diagram before choosing between 1-pilot Type G-GC and 2-control-core Type PCG.
Type PG & Type PCG Mining Cable RFQ Checklist
- Designation and core count: Type PG or Type PCG, 2-conductor (DC/1-phase) or 3-conductor (3-phase) plus conductor AWG/kcmil.
- Control conductor gauge (Type PCG): standard 10/8 AWG pair or custom 12 AWG / reinforced 8 AWG control cores.
- Outer jacket polymer and color: standard extra-heavy-duty black CPE, polychloroprene (PCP/CSP), or high-visibility yellow/orange TPU (-40 °C).
- Installation duty: free trailing on mine floor, rib-hook suspension, or motorized reeling drum (state drum barrel diameter and layers).
- Cut length per reel and total project meterage (MOQ 50 m; manufacturing lead time 7 to 45 working days).
Related selection resources
- Mining & Tunneling Cables Full Catalog
- TPU vs. CPE Mining Trailing Cable Jacket Selection Guide
- Mining Cable Selection Guide: 8 Steps for Mobile Equipment
- Type G 2000 V 4-Conductor Portable Mining Power Cable
- Type SHD-PCG 2 kV Shielded Power & Control Mining Cable
Type PG & Type PCG Portable Mining Cable FAQ
What is the difference between Type PG, Type PCG and Type G-GC mining cable?
2 insulated control conductors vs. 1 ground-check wire is the core difference: Type PG contains 2 or 3 power cores plus 1 bare ground (no pilot); Type PCG adds 2 insulated control/pilot conductors alongside 1 bare ground; Type G-GC splits the ground into 2 symmetrical wires plus 1 yellow ground-check core.
Does Type PCG 600/2000 V cable include individual metallic shields over the power phases?
No. Type PCG is an unshielded 600/2000 V portable power and control cable per ICEA S-75-381; if mine regulations or 2.4–5 kV longwall switchgear mandate individual tinned-copper braid shields plus control cores, specify Type SHD-PCG instead.
What size are the control conductors inside Type PCG mining cable?
10 AWG is standard on 8 AWG through 2 AWG Type PCG cables, stepping up to 8 AWG heavy-duty control conductors from 1 AWG through 500 kcmil to resist tensile snapping under continuous-miner and roof-bolter flexing.
Can Type PG and Type PCG be manufactured with an extra-heavy-duty TPU jacket instead of CPE?
Yes. In addition to standard mold-cured black thermoset CPE, TEBAOFLEX extrudes optional high-visibility yellow or orange ether-based polyurethane (TPU) jackets rated down to -40 °C for wet, sharp hard-rock drifts.
What is the minimum order quantity and lead time for Type PG & Type PCG cable?
50 m per size is our minimum order quantity, supplied on export wooden or steel-wood drums with a manufacturing lead time of 7 to 45 working days.
Type PG & Type PCG Technical Specifications & Size Charts
Type PG & Type PCG Key Engineering Highlights
- Type PG vs Type PCG circuit layout: Type PG pairs 2 or 3 EPR power cores with 1 uninsulated ground; Type PCG adds 2 insulated control/ground-check cores (12, 10 or 8 AWG) in the outer interstices
- 600/2000 V 90 °C EPR dielectric: Ozone-, moisture- and heat-resistant ethylene propylene rubber (EPR) rated +90 °C continuous, +130 °C emergency overload and +250 °C short-circuit
- Rope-lay tinned copper flex life: ASTM B33 and ASTM B172 flexible rope-stranded tinned copper resists acid mine water corrosion and repetitive bending on shuttle sheaves and face reels
- Reinforced CPE or EHD TPU jacket: Mold-cured extra-heavy-duty black CPE jacket over cord reinforcement (optional high-visibility yellow/orange polyurethane TPU for sharp muck piles)
- 50 m MOQ & custom length reels: Manufactured to order from 50 m minimum order quantity per gauge with a 7 to 45 working days lead time
| Parameter | Value |
|---|---|
| Rated voltage | 600/2000 V AC and DC portable mining power service (engineered to ICEA S-75-381 and NEMA WC 58) |
| Operating temperature range | -40 °C to +90 °C continuous conductor temperature (+130 °C overload, +250 °C short-circuit); -40 °C cold-bend TPU option |
| Conductor and core layout | ASTM B33 and ASTM B172 rope-lay tinned copper (8 AWG to 500 kcmil): Type PG (2/C or 3/C + 1 ground) and Type PCG (2/C or 3/C + 1 ground + 2 control) |
| Insulation and outer jacket | 90 °C EPR phase and control insulation under cord-reinforced extra-heavy-duty black CPE jacket (optional PCP, CSP or TPU) |
| Minimum bending radius | 6 × cable overall diameter for fixed/trailing routing; 8 × overall diameter recommended on motorized reeling drums |
| Flame and abrasion compliance | Engineered with reference to 30 CFR Part 7 / FT1 / FT5 flame-retardant jacket criteria; third-party listing is not claimed |
| Minimum order and lead time | 50 m minimum order quantity per configuration; manufacturing lead time 7 to 45 working days |
Type PG 600/2000 V (3 Power + 1 Ground) Dimensional & Ampacity Schedule
| Model & Gauge | Power Stranding | EPR Wall (mm) | Ground Size (AWG) | Nominal OD (mm / in) | Approx. Weight (kg/km) | Ampacity @40 °C (A) | MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| Type PG 3/C 8 AWG | 133 (7×19) | 1.52 | 8 AWG | 23.1 / 0.91 | 775 | 72 | 50 m | Request this size |
| Type PG 3/C 6 AWG | 259 (7×37) | 1.52 | 6 AWG | 25.7 / 1.01 | 1042 | 93 | 50 m | Request this size |
| Type PG 3/C 4 AWG | 259 (7×37) | 1.52 | 6 AWG | 29.2 / 1.15 | 1430 | 122 | 50 m | Request this size |
| Type PG 3/C 2 AWG | 259 (7×37) | 1.52 | 4 AWG | 33.5 / 1.32 | 2040 | 159 | 50 m | Request this size |
| Type PG 3/C 1 AWG | 259 (7×37) | 2.03 | 4 AWG | 38.4 / 1.51 | 2620 | 184 | 50 m | Request this size |
| Type PG 3/C 1/0 AWG | 266 (19×14) | 2.03 | 3 AWG | 41.4 / 1.63 | 3170 | 211 | 50 m | Request this size |
| Type PG 3/C 2/0 AWG | 342 (19×18) | 2.03 | 2 AWG | 44.5 / 1.75 | 3840 | 243 | 50 m | Request this size |
| Type PG 3/C 3/0 AWG | 418 (19×22) | 2.03 | 1 AWG | 48.0 / 1.89 | 4615 | 279 | 50 m | Request this size |
| Type PG 3/C 4/0 AWG | 532 (19×28) | 2.03 | 1/0 AWG | 52.1 / 2.05 | 5625 | 321 | 50 m | Request this size |
| Type PG 3/C 250 kcmil | 627 (19×33) | 2.41 | 1/0 AWG | 59.4 / 2.34 | 6980 | 355 | 50 m | Request this size |
| Type PG 3/C 350 kcmil | 888 (37×24) | 2.41 | 2/0 AWG | 66.8 / 2.63 | 9240 | 435 | 50 m | Request this size |
| Type PG 3/C 500 kcmil | 1221 (37×33) | 2.41 | 4/0 AWG | 73.9 / 2.91 | 12480 | 536 | 50 m | Request this size |
Type PCG 600/2000 V (3 Power + 1 Ground + 2 Control) Dimensional & Ampacity Schedule
| Model & Gauge | Power Stranding | Ground Size | Control Cores | Nominal OD (mm / in) | Approx. Weight (kg/km) | Ampacity @40 °C (A) | MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| Type PCG 3/C 8 AWG | 133 (7×19) | 8 AWG | 2 × 10 AWG | 24.6 / 0.97 | 865 | 72 | 50 m | Request this size |
| Type PCG 3/C 6 AWG | 259 (7×37) | 6 AWG | 2 × 10 AWG | 26.7 / 1.05 | 1130 | 93 | 50 m | Request this size |
| Type PCG 3/C 4 AWG | 259 (7×37) | 6 AWG | 2 × 10 AWG | 30.2 / 1.19 | 1525 | 122 | 50 m | Request this size |
| Type PCG 3/C 2 AWG | 259 (7×37) | 4 AWG | 2 × 10 AWG | 34.3 / 1.35 | 2145 | 159 | 50 m | Request this size |
| Type PCG 3/C 1 AWG | 259 (7×37) | 4 AWG | 2 × 8 AWG | 39.1 / 1.54 | 2740 | 184 | 50 m | Request this size |
| Type PCG 3/C 1/0 AWG | 266 (19×14) | 3 AWG | 2 × 8 AWG | 42.2 / 1.66 | 3295 | 211 | 50 m | Request this size |
| Type PCG 3/C 2/0 AWG | 342 (19×18) | 2 AWG | 2 × 8 AWG | 45.2 / 1.78 | 3965 | 243 | 50 m | Request this size |
| Type PCG 3/C 3/0 AWG | 418 (19×22) | 1 AWG | 2 × 8 AWG | 48.8 / 1.92 | 4750 | 279 | 50 m | Request this size |
| Type PCG 3/C 4/0 AWG | 532 (19×28) | 1/0 AWG | 2 × 8 AWG | 52.8 / 2.08 | 5760 | 321 | 50 m | Request this size |
| Type PCG 3/C 250 kcmil | 627 (19×33) | 1/0 AWG | 2 × 8 AWG | 60.2 / 2.37 | 7120 | 355 | 50 m | Request this size |
| Type PCG 3/C 350 kcmil | 888 (37×24) | 2/0 AWG | 2 × 8 AWG | 67.3 / 2.65 | 9390 | 435 | 50 m | Request this size |
| Type PCG 3/C 500 kcmil | 1221 (37×33) | 4/0 AWG | 2 × 8 AWG | 74.4 / 2.93 | 12640 | 536 | 50 m | Request this size |
Ampacity values follow ICEA S-75-381 / NEMA WC 58 single-cable in free air at +40 °C ambient and +90 °C conductor temperature; apply reel-layer derating (0.85 for 1 layer, 0.65 for 2 layers, 0.45 for 3 layers) on cable reels, and final values are confirmed on the quotation drawing.
2-conductor (2/C) Type PG and Type PCG DC/single-phase builds (8 AWG to 4/0 AWG) are manufactured to the same ICEA S-75-381 wall schedule on request.
ASCII part references for BOM and ERP entry: TF-MIN-PG-PCG-2KV, TYPE-PG-3C-2AWG, TYPE-PG-3C-2/0AWG, TYPE-PG-3C-4/0AWG, TYPE-PCG-3C-4AWG, TYPE-PCG-3C-2AWG, TYPE-PCG-3C-2/0AWG, TYPE-PCG-3C-4/0AWG.
Type PG & Type PCG Standards & Test References
| Standard or specification | Application |
|---|---|
| ICEA S-75-381 / NEMA WC 58 | Primary North American construction, dimensional, ground/control sizing and ampacity specification for Type PG and Type PCG portable mining cables. |
| ASTM B33 & ASTM B172 | Tinned soft-annealed copper wire and rope-lay bunch-stranded flexible conductor specifications. |
| CAN/CSA C22.2 No. 96 | Canadian portable power cable dimensional and -40 °C cold-bend / FT1 / FT5 jacket reference where specified on order. |
| 30 CFR Part 7 (Reference) | Engineered with reference to flame-test criteria for underground coal and gassy-mine trailing cables; third-party regulatory listing is not claimed. |
ANSI/NEMA WC 58 / ICEA S-75-381 Portable Mining Cable Standard
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type G 2000 V 4-Conductor Portable Mining Power Cable with Symmetrical Grounds (8 AWG–500 kcmil)
A related cable option for a different application or duty profile.
View productFlat Type G 2/C 2000 V Twin Parallel Portable DC Mining & Shuttle-Car Reeling Cable (6 AWG–4/0 AWG)
A related cable option for a different application or duty profile.
View productType SHD Flat 3/C 2000 V Individually Shielded Portable Mining Reeling & Shuttle-Car Cable (6 AWG–4/0 AWG)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.