NSHXOEU-O / NSHXOEU-J 0.6/1 kV Flexible Mining Cable
Combined O single-core and J multi-core 0.6/1 kV flexible mining cable for tunnel, open-cast, quarry and industrial routes.
NSHXOEU-O / NSHXOEU-J is one combined 0.6/1 kV flexible mining-cable page covering the O single-core and J multi-core configurations. The supplied VDE datasheet positions the family for underground mining, tunnel building, open-cast mining, quarries, construction sites and industrial routes with medium mechanical stress. It describes finely stranded tinned copper conductors to DIN VDE 0295 and IEC 60228, 3GI3 EPR insulation, core identification by colour or black numbering, a GM1B inner sheath for multi-core cables and a yellow 5GM3 outer sheath. The source lists 3 kV main-core testing, 90 °C conductor operation, 250 °C short-circuit temperature, fixed service from −40 °C to +90 °C, fully flexible service from −25 °C to +90 °C and a maximum water temperature of 40 °C. O entries include 300 mm² and 400 mm² single cores; J entries cover the supplied three-, four- and five-core arrangements. The combined page prevents duplicate O/J records while keeping the technical distinction visible for purchasing and engineering review. Confirm whether O or J is required, together with water condition, site classification, conductor size, route, bending radius, current derating and termination before ordering.
NSHXOEU-O and NSHXOEU-J construction
The supplied NSHXOEU family covers an O single-core configuration and J multi-core configurations. Both use finely stranded tinned copper, 3GI3 EPR insulation and a 5GM3 yellow outer sheath; the source specifies a GM1B inner sheath for multi-core construction and identifies the core arrangement by core count.

| Parameter | Source-listed value |
|---|---|
| Conductor | Tinned copper, finely stranded class 5 according to DIN VDE 0295 / IEC 60228 |
| Insulation | EPR rubber compound type 3GI3 |
| Core identification | Up to 5 cores coloured according to DIN VDE 0293-308; from 6 cores light with black numbers |
| Inner sheath | EPR rubber compound type GM1B; not for single-core cables |
| Outer sheath | EVA-based rubber compound type 5GM3, yellow |
| Page structure | O and J configurations remain on one canonical product page |
The O/J distinction changes the core arrangement and ordering data. Do not select a single-core O entry where the equipment requires the multi-core J protective-conductor arrangement.
Applications for NSHXOEU-O / NSHXOEU-J
The supplied application covers flexible use and fixed installation in underground mining, tunnel building, open-cast mining, quarries, construction sites and similar duties with medium mechanical stress. It lists indoor and outdoor use, plus use in explosion-hazard areas subject to the applicable site requirements.

- Underground, tunnelling, open-cast, quarry and construction-site routes with medium mechanical stress
- O single-core configurations and J multi-core configurations listed in the supplied data
- Indoor and outdoor installations, with the source also listing explosion-hazard-area use subject to site rules
- Permanent waste-water service up to 40 °C is listed; groundwater and seawater use is more limited and must be confirmed
- Confirm conductor size, core function, fixed/flexible mode, current derating, water conditions and termination before quotation
The source provides a maximum water temperature but does not make every water environment interchangeable. Send the actual fluid, depth/route and movement conditions with the RFQ.
NSHXOEU-O and NSHXOEU-J specifications
O and J configurations are kept on one canonical page. The supplied tables retain the separate single-core O and multi-core J entries so the buyer can compare construction, diameter, weight and electrical values without creating duplicate size pages.
| Parameter | Source-listed value |
|---|---|
| Rated voltage U₀/U | 0.6/1 kV |
| Maximum permissible AC operating voltage | 0.7/1.2 kV |
| Maximum permissible DC operating voltage | 0.9/1.8 kV |
| AC test voltage — main cores | 3 kV / 5 min |
| AC test voltage — control cores | 2 kV |
| Maximum conductor operating temperature | +90 °C |
| Maximum conductor short-circuit temperature | +250 °C |
| Fixed ambient temperature | −40 °C to +90 °C |
| Fully flexible ambient temperature | −25 °C to +90 °C |
| Maximum water temperature | +40 °C |
| Maximum tensile load on conductor | 15 N/mm² |
| Minimum bending radius | According to DIN VDE 0298 Part 3 |
| Type / core arrangement | Conductor diameter max. (mm) | Outer diameter min. (mm) | Outer diameter max. (mm) | Fixed bending radius min. (mm) | Weight (kg/km) | Tensile force max. (N) |
|---|---|---|---|---|---|---|
| NSHXOEU-O 1 × 300 | 22.9 | 34.5 | 36.8 | 147 | 3330 | 4500 |
| NSHXOEU-O 1 × 400 | 26.2 | 38.5 | 40.5 | 162 | 4210 | 6000 |
| NSHXOEU-J 3 × 2.5 | 2 | 12 | 13.6 | 54 | 250 | 113 |
| NSHXOEU-J 3 × 50/25 | 8.8 | 38.1 | 41.1 | 164 | 2930 | 3000 |
| NSHXOEU-J 3 × 70/35 | 10.6 | 42.3 | 45.3 | 181 | 3790 | 4200 |
| NSHXOEU-J 3 × 95/50 | 12.1 | 48.2 | 52.2 | 209 | 5170 | 5700 |
| NSHXOEU-J 3 × 120/70 | 14.2 | 54.6 | 58.6 | 234 | 6482 | 7200 |
| NSHXOEU-J 3 × 150/70 | 16.1 | 60 | 64 | 256 | 7568 | 9000 |
| NSHXOEU-J 3 × 185/95 | 17.9 | 67.3 | 71.3 | 285 | 9328 | 11100 |
| NSHXOEU-J 4 × 2.5 | 2 | 14.2 | 16 | 64 | 310 | 150 |
| NSHXOEU-J 5 × 1.5 | 1.6 | 12.7 | 14.3 | 57 | 250 | 113 |
| NSHXOEU-J 5 × 2.5 | 2 | 14.7 | 16.7 | 67 | 380 | 188 |
| NSHXOEU-J 5 × 4 | 2.4 | 16.5 | 18.5 | 74 | 500 | 300 |
| NSHXOEU-J 5 × 6 | 2.9 | 18.6 | 20.6 | 82 | 660 | 450 |
| NSHXOEU-J 5 × 10 | 3.9 | 22.5 | 24.5 | 98 | 1000 | 750 |
| NSHXOEU-J 5 × 16 | 5.4 | 26.7 | 29.7 | 119 | 1440 | 1200 |
| NSHXOEU-J 5 × 25 | 6.3 | 31.7 | 34.7 | 139 | 2110 | 1875 |
| NSHXOEU-J 5 × 35 | 7.5 | 36.9 | 39.9 | 160 | 2743 | 2625 |
| Type / core arrangement | Conductor resistance at 20 °C max. (Ω/km) | Operating capacitance nom. (µF/km) | Inductance nom. (mH/km) | Current carrying capacity (A) | Short-circuit current conductor (kA) |
|---|---|---|---|---|---|
| NSHXOEU-O 1 × 300 | 0.0654 | 0.76 | 0.23 | 843 | 42.9 |
| NSHXOEU-O 1 × 400 | 0.0495 | 0.76 | 0.24 | 1024 | 57.2 |
| NSHXOEU-J 3 × 2.5 | 8.21 | 0.23 | 0.32 | 30 | 0.36 |
| NSHXOEU-J 3 × 50/25 | 0.393 | 0.5 | 0.25 | 202 | 7.15 |
| NSHXOEU-J 3 × 70/35 | 0.277 | 0.59 | 0.24 | 250 | 10.01 |
| NSHXOEU-J 3 × 95/50 | 0.21 | 0.6 | 0.24 | 301 | 13.59 |
| NSHXOEU-J 3 × 120/70 | 0.164 | 0.69 | 0.23 | 352 | 17.16 |
| NSHXOEU-J 3 × 150/70 | 0.132 | 0.7 | 0.23 | 404 | 21.45 |
| NSHXOEU-J 3 × 185/95 | 0.108 | 0.71 | 0.23 | 461 | 26.46 |
| NSHXOEU-J 4 × 2.5 | 8.21 | 0.23 | 0.32 | 30 | 0.36 |
| NSHXOEU-J 5 × 1.5 | 13.7 | 0.22 | 0.33 | 23 | 0.21 |
| NSHXOEU-J 5 × 2.5 | 8.21 | 0.23 | 0.32 | 30 | 0.36 |
| NSHXOEU-J 5 × 4 | 5.09 | 0.26 | 0.31 | 41 | 0.57 |
| NSHXOEU-J 5 × 6 | 3.39 | 0.3 | 0.29 | 53 | 0.86 |
| NSHXOEU-J 5 × 10 | 1.95 | 0.32 | 0.28 | 74 | 1.43 |
| NSHXOEU-J 5 × 16 | 1.24 | 0.42 | 0.26 | 99 | 2.29 |
| NSHXOEU-J 5 × 25 | 0.795 | 0.42 | 0.26 | 131 | 3.58 |
| NSHXOEU-J 5 × 35 | 0.565 | 0.49 | 0.25 | 162 | 5.01 |
Nominal current carrying capacity is for rubber cables laid on a surface at 30 °C ambient temperature; apply the applicable technical appendix derating factors.
NSHXOEU-O / NSHXOEU-J standards and tests
The page keeps O and J under one product intent while preserving the supplied construction and test references.
| Parameter | Source-listed value |
|---|---|
| Construction | Based on DIN VDE 0250 Part 812 |
| Flame propagation | DIN EN 60332-1-2 |
| Resistance to oil | DIN EN 60811-2-1 |
| Water resistance | EN 50525-2-21 |
| Source-listed installation | Indoor and outdoor use; site-specific requirements apply |
Confirm the required standard edition, site classification, water-duty documentation and final O/J marking with the quotation request.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
(N)SHOEU 0.6/1kV Mining Rubber Flexible Cable
A related cable option for a different application or duty profile.
View productNTSKCGWÖU 0.6/1 (1.2) kV Mining Loader Cable
A related cable option for a different application or duty profile.
View productNTSWÖU-J 0.6/1kV Flexible Trailing Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.