Welding Cables TEBAOFLEX

0361TQ BS 638 Part 4 100 V EPR/CSP (HOFR) Flexible Arc Welding Cable (16–240 mm²)

0361TQ BS 638 Part 4 Welding Cable is the British-standard two-layer elastomeric arc-welding lead engineered for high-current shipyard, offshore module, automotive assembly and heavy machine-tool welding from 16 mm² to 240 mm². Combining Class 6 (16–95 mm²) and Class 5 (120–240 mm²) tinned or plain annealed copper, neutral GP4 EPR primary insulation and a rugged orange or black EM5 CSP (HOFR) outer sheath, it carries 100 V welding duty (450 V non-welding when mechanically protected).

Product information
SKU
TF-0361TQ-BS638
Brand
TEBAOFLEX
Product overview

0361TQ BS 638 Part 4 EPR/CSP (HOFR) Welding Cable remains the preferred heavy-duty specification across UK, North Sea offshore, Middle Eastern petrochemical and Commonwealth shipyard projects whenever engineers demand two-layer elastomeric protection and tinned-copper corrosion resistance.

Although CENELEC harmonized standard BS EN 50525-2-81 (`H01N2-D / H01N2-E`) formally superseded BS 638 Part 4 for single-layer EM5 leads, engineering contractors continue to specify Type 0361TQ specifically for its superior dual-layer elastomer wall and tinned conductor option: an inner neutral ethylene propylene rubber (EPR Type GP4) layer maintains high dielectric integrity and thermal stability up to +85 °C, while an outer chlorosulphonated polyethylene (CSP / HOFR Type EM5) sheath in high-visibility orange or black shrugs off cutting oils, salt spray, diesel splashes, weld spatter and IEC 60332-1-2 vertical flame propagation. Sizes 16 mm² through 95 mm² utilize Class 6 extra-flexible copper (0.20–0.21 mm strands), stepping to Class 5 (0.50–0.51 mm strands) across 120 mm² to 240 mm² heavy bus-welder feeders.

Choose Orange Tinned-Copper 0361TQ for coastal shipyards, offshore topside maintenance and high-visibility automotive conveyor lines, or Black Plain-Copper 0361TQ for general heavy fabrication; compare `H01N2-E` (`WC 3465`) when ultra-fine 0.15 mm robotic/handheld flexibility is prioritized. Bulk drum MOQ 300 m with optional cold-crimped copper lugs per terminal drawing; lead time 7 to 45 working days.

Explore the welding cable range for related configurations.

Construction

0361TQ BS 638 Part 4 Cable Construction

Concentric two-layer thermoset elastomer construction built in accordance with BS 638 Part 4, BS 7655 and BS EN 50363 in tinned-copper orange CSP and plain-copper black HOFR configurations.

0361TQ BS 638 Part 4 single-core welding cable axial cross-section showing orange CSP HOFR outer sheath, neutral EPR insulation ring and tinned fine copper core
Two-layer axial cross-section of 0361TQ pairing neutral EPR primary insulation with an oil- and flame-retardant CSP/HOFR outer sheath.
0361TQ BS 638 Part 4 100 V EPR/CSP (HOFR) Flexible Arc Welding Cable (16–240 mm²) construction
ComponentMaterial and construction
1. Extra-Flexible Tinned or Plain Copper Conductor16–95 mm²: BS EN 60228 Class 6 extra-flexible tinned or plain copper (0.20–0.21 mm wires). 120–240 mm²: Class 5 flexible tinned or plain copper (0.50–0.51 mm wires).
2. Polyester (PET) Separator TapeClean longitudinal PET film wrap prevents elastomer vulcanization bonding to the tinned or bare copper strands.
3. Neutral GP4 EPR Primary InsulationEthylene propylene rubber (Type GP4 to BS 7655) delivering high dielectric strength, ozone immunity and -20 °C to +85 °C flexing stability.
4. Heavy-Duty CSP / HOFR (Type EM5) Outer SheathHeat- and oil-resistant, flame-retardant (BS EN / IEC 60332-1-2) chlorosulphonated polyethylene / EM5 elastomer sheath in high-visibility orange or black.

0361TQ, GP4 EPR & HOFR Designation Breakdown

  • 0361TQ (BS 638 Part 4): UK CMA cable code for single-core flexible EPR-insulated, CSP/HOFR-sheathed arc-welding cable up to 85 °C
  • GP4 EPR Insulation: British Standard BS 7655 Type GP4 cross-linked ethylene propylene rubber primary dielectric layer
  • CSP / HOFR (Type EM5): Chlorosulphonated polyethylene / Heat, Oil-Resistant and Flame-Retardant thermoset outer sheath per BS EN 50363
  • 100 V Weld / 450 V Protected: Rated 100 V for open shop-floor welding leads, and up to 450 V for non-welding low-voltage equipment leads when mechanically protected
  • I = I100 × sqrt(100 / F): BS 638 Part 4 5-minute duty-cycle current multiplier formula, where F is the loaded percentage of a 5-minute cycle
Applications

0361TQ BS 638 Part 4 Welding Applications

Built for high-amperage manual, semi-automatic (65–85% duty) and fully automatic (100% duty) welding lines in harsh industrial and marine environments.

0361TQ orange BS 638 Part 4 flexible welding cables routed from industrial welding power sources along an offshore steel and automotive fabrication bay
Assembly-line and offshore structural welding station equipped with high-visibility orange 0361TQ BS 638 Part 4 leads.
  • Shipbuilding drydocks, offshore oil-and-gas jacket fabrication and coastal repair yards specifying tinned-copper orange 0361TQ welding leads.
  • Automotive body-in-white assembly lines, conveyor welding stations, machine-tool plants and heavy structural steel workshops.
  • Manual MMA/stick (30–60% duty), semi-automatic MIG/MAG (65–85% duty) and fully automatic submerged-arc / spot-welding power feeds (100% duty).
  • Protected 450 V low-voltage high-current DC/AC flexible equipment interconnections where BS 638-4 0361TQ is specified.
  • Bulk drum supply (MOQ 300 m) with optional custom cold-crimped tinned copper tubular lugs matched to British/metric stud sizes.

0361TQ BS 638-4 vs. H01N2-D/E & IEC 60245 Comparison

0361TQ (BS 638 Part 4) vs. H01N2-D / H01N2-E (EN 50525-2-81) vs. 60245 IEC 82 (YHF)
Cable TypeLayer ArchitectureStandard Conductor FinishSheath ColorsKey Engineering Advantage
0361TQ Orange (BS 638-4)Two-layer: GP4 EPR + CSP (HOFR)Tinned copper (Class 6 / 5)High-visibility OrangeSalt-spray corrosion protection + two-layer dielectric wall
0361TQ Black (BS 638-4)Two-layer: GP4 EPR + EM5 HOFRPlain or tinned copperBlack450 V protected non-welding rating + UK BS 638-4 replacement
H01N2-D / H01N2-E (WC 3465)Single-layer EM5 (or EI7+EM5)Plain copper (0.20 / 0.15 mm)Black (Red optional)Lighter OD & ultra-supple 0.15 mm Class E robotic/whip option
60245 IEC 82 / YHF (NW3)Single-layer SE4 polychloroprenePlain copper Class 6BlackDirect IEC 60245-6 / GB/T 5013.6 tender code match

Although BS 638 Part 4 was withdrawn in favor of BS EN 50525-2-81, 0361TQ remains widely specified in UK/offshore BOQs because its separate EPR primary insulation + CSP outer sheath and tinned copper resist marine oxidation and 450 V protected equipment duty.

0361TQ BS 638 Part 4 Welding Cable RFQ Checklist

  • Variant choice: Orange CSP sheath with tinned copper conductor vs. Black HOFR sheath with plain (or tinned) copper conductor.
  • Nominal cross-section (16 mm² through 240 mm²) and gland entry diameter constraint if entering fixed welder enclosures.
  • Welding duty cycle (100% automatic, 85% semi-auto, 60% manual or 35% intermittent) and ambient temperature.
  • Bulk drum meterage per size (standard MOQ 300 m; manufacturing lead time 7 to 45 working days).
  • Optional custom cold-crimped tinned copper tubular lug dimensions per terminal bolt drawing.

Related selection resources

0361TQ BS 638 Part 4 Welding Cable FAQ

How does 0361TQ BS 638 Part 4 welding cable differ from H01N2-D?

0361TQ uses a two-layer elastomeric wall—neutral GP4 EPR primary insulation beneath a separate orange or black CSP (HOFR) outer sheath—frequently paired with tinned copper conductors, whereas standard H01N2-D uses a single-layer black EM5 rubber covering over bare copper.

Can 0361TQ BS 638 welding cable be used at 450 V in non-welding equipment?

Yes. While rated 100 V for exposed shop-floor arc-welding leads, 0361TQ's dual EPR + HOFR wall permits up to 450 V service in non-welding power connections when the cable is suitably protected against mechanical damage.

Why specify tinned copper on orange 0361TQ BS 638 welding cable?

0.20 mm fine copper strands oxidize rapidly in coastal shipyards, offshore oil rigs and damp workshops, raising crimp-lug contact resistance; tin-plating every strand prevents sulfide/salt tarnishing and keeps voltage drop stable over years of service.

How do I calculate 0361TQ current capacity for a 20% or 50% duty cycle?

Multiply the 100% continuous current rating (I100) from BS 638 Part 4 Table A.5 by sqrt(100 / F), where F is the duty-cycle percentage over a 5-minute period—for example, 50 mm² (I100 = 285 A) carries 285 × sqrt(100 / 50) = 403 A at 50% duty in 25 °C air.

What is the MOQ and lead time for 0361TQ BS 638 welding cable?

300 m per cross-section and sheath color is our standard bulk drum MOQ with a 7 to 45 working days lead time, and matched cold-crimped tinned copper lugs can be supplied to your drawing.

Specifications

0361TQ BS 638 Part 4 Technical Specifications

0361TQ Key Engineering Highlights

  • True two-layer GP4 EPR + EM5 CSP (HOFR) build: Unlike single-layer rubber leads, 0361TQ pairs neutral BS 7655 GP4 EPR dielectric insulation with a separate heat-, oil- and flame-retardant CSP/HOFR sheath
  • Tinned or plain Class 6 / Class 5 copper: Available with corrosion-resistant tinned copper (0.20 mm wires up to 95 mm²) for marine/offshore yards or plain annealed copper per BS EN 60228
  • 100 V welding & 450 V protected non-welding rating: Rated 100 V across occasional to 100% automatic welding cycles, and up to 450 V in non-welding low-voltage applications when protected from mechanical damage
  • BS 638-4 Table A.5 ampacity & gland schedule: Full 16–240 mm² 5-minute duty-cycle current capacities (100% / 85% / 60% / 35%), ambient derating (25–45 °C) and metric cable-gland references (20S–40)
  • 300 m bulk MOQ & matched copper lugs: Manufactured in safety-orange or black sheaths at 300 m MOQ (7 to 45 working days) with optional custom cold-crimped tinned/bare copper lugs per drawing
0361TQ BS 638 Part 4 100 V EPR/CSP (HOFR) Flexible Arc Welding Cable (16–240 mm²) technical data
ParameterValue
Rated voltage100 V AC/DC for arc-welding secondary circuits (up to 450 V for non-welding applications if suitably protected from mechanical damage)
Operating temperature range-20 °C to +85 °C in flexible service (minimum installation temperature 0 °C); +85 °C max continuous conductor temperature
Conductor optionsTinned or plain annealed copper per BS EN 60228: Class 6 extra-flexible (16 to 95 mm²) and Class 5 flexible (120 to 240 mm²)
Insulation and outer sheathNeutral GP4 EPR rubber insulation + orange or black CSP / HOFR (Type EM5) oil-resistant, flame-retardant outer sheath
Minimum bending radius6 × overall cable diameter in flexible welding service; flame retardant to BS EN / IEC 60332-1-2
Minimum order and lead time300 m minimum order quantity per cross-section and sheath color; manufacturing lead time 7 to 45 working days

0361TQ BS 638 Part 4 Exact Dimensional & Gland Schedule (16–240 mm²)

0361TQ BS 638 Part 4 Dimensional, Conductor & Gland Reference Schedule (Black Class 6/5 & Orange Tinned Cu, 16–240 mm²)
Model & Size (mm²)Conductor Class & StrandingCovering Radial Wall (mm)Black HOFR OD / Wt (mm / kg/km)Orange CSP OD / Wt (mm / kg/km)Max Plain Cu R @20 °C (Ω/km)Gland RefBulk MOQNext step
0361TQ BS 638 1×16Class 6 (513 × 0.20 mm)2.09.7 / 21511.5 / 2351.2120S300 mRequest this size
0361TQ BS 638 1×25Class 6 (783 × 0.20 mm)2.011.2 / 30513.0 / 3300.78020300 mRequest this size
0361TQ BS 638 1×35Class 6 (1107 × 0.20 mm)2.012.4 / 40014.5 / 4400.55425300 mRequest this size
0361TQ BS 638 1×50Class 6 (1566 × 0.20 mm)2.214.3 / 58717.0 / 6100.38625300 mRequest this size
0361TQ BS 638 1×70Class 6 (2214 × 0.20 mm)2.416.3 / 77519.5 / 8400.27232300 mRequest this size
0361TQ BS 638 1×95Class 6 (2997 × 0.20 mm)2.618.6 / 104022.0 / 11200.20632300 mRequest this size
0361TQ BS 638 1×120Class 5 (608 × 0.50 mm)2.820.3 / 125624.0 / 14100.16132300 mRequest this size
0361TQ BS 638 1×150Class 5 (760 × 0.50 mm)3.022.6 / 151026.5 / 17300.12940300 mRequest this size
0361TQ BS 638 1×185Class 5 (925 × 0.50 mm)3.224.7 / 187529.0 / 21000.10640300 mRequest this size
0361TQ BS 638 1×240Class 5 (1220 × 0.50 mm)3.427.8 / 253432.0 / 26900.081750S300 mRequest this size

0361TQ BS 638 Part 4 Table A.5 Duty-Cycle Ampacity & Ambient Derating

BS 638 Part 4 Table A.5 Current Carrying Capacity (5-Minute Duty Cycle at 25 °C Ambient) & Table A.7 Ambient Derating
Cross-Section (mm²)100% Auto Duty (A)85% Semi-Auto Duty (A)60% Manual Duty (A)35% Intermittent Duty (A)Derating 30°C / 35°C / 40°C / 45°C
16 mm²1351451752300.96 / 0.91 / 0.87 / 0.82
25 mm²1801952303000.96 / 0.91 / 0.87 / 0.82
35 mm²2252452903750.96 / 0.91 / 0.87 / 0.82
50 mm²2853053654800.96 / 0.91 / 0.87 / 0.82
70 mm²3553854606000.96 / 0.91 / 0.87 / 0.82
95 mm²4304705607300.96 / 0.91 / 0.87 / 0.82
120 mm²5005406508500.96 / 0.91 / 0.87 / 0.82
150 mm²5806307509800.96 / 0.91 / 0.87 / 0.82
185 mm²66572086011200.96 / 0.91 / 0.87 / 0.82
240 mm²78085097512500.96 / 0.91 / 0.87 / 0.82

Sizes 16 mm² through 185 mm² conform directly to BS 638 Part 4; 240 mm² is manufactured generally to BS 638 Part 4 extended geometry. Tinned copper conductors have slightly higher 20 °C DC resistance per BS EN 60228 Class 6/5 tables (e.g., 1.24 Ω/km at 16 mm², 0.393 Ω/km at 50 mm²).

For duty cycles F (%) not tabulated above over a 5-minute period, calculate maximum permissible current as I = I100 × sqrt(100 / F), then multiply by the Table A.7 ambient temperature factor above 25 °C.

ASCII part references for BOM and ERP entry: TF-0361TQ-OR-16, TF-0361TQ-OR-25, TF-0361TQ-OR-35, TF-0361TQ-OR-50, TF-0361TQ-OR-70, TF-0361TQ-OR-95, TF-0361TQ-OR-120, TF-0361TQ-OR-185, TF-0361TQ-BK-16, TF-0361TQ-BK-25, TF-0361TQ-BK-35, TF-0361TQ-BK-50, TF-0361TQ-BK-70, TF-0361TQ-BK-95, TF-0361TQ-BK-120, TF-0361TQ-BK-150, TF-0361TQ-BK-185, TF-0361TQ-BK-240.

Standards

0361TQ BS 638 Part 4 Standards & Test References

0361TQ BS 638 Part 4 100 V EPR/CSP (HOFR) Flexible Arc Welding Cable (16–240 mm²) standards and test references
Standard or specificationApplication
BS 638 Part 4British construction and current-rating specification for flexible arc-welding power source to electrode/gun leads up to 185 mm² (extended to 240 mm²).
BS EN 60228 (formerly BS 6360)Class 6 extra-flexible (16–95 mm²) and Class 5 flexible (120–240 mm²) tinned and plain copper conductor standard.
BS 7655 (GP4) & BS EN 50363 (EM5)Elastomeric EPR primary insulation (Type GP4) and heat-, oil- and flame-retardant CSP/HOFR outer sheath (Type EM5) specifications.
BS EN / IEC 60332-1-2Single vertical cable flame-retardance test compliance.

BS 638-4 Specification for Arc Welding Cables (0361TQ Reference)

BS EN / IEC 60332-1-2 Single-Cable Flame Propagation Test

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.