60245 IEC 81 (YH) & 60245 IEC 82 (YHF) Class 6 Rubber & Polychloroprene Welding Cable (10–185 mm²)
60245 IEC 81 (YH) & 60245 IEC 82 (YHF) Welding Cable is the international IEC 60245-6 and GB/T 5013.6 single-core arc-welding electrode lead specified across EPC infrastructure, shipyard, pipeline and structural steel tenders from 10 mm² to 185 mm². Built around IEC 60228 Class 6 extra-flexible copper conductors (max 0.21 mm wire diameter) and a 1,000 V / 5 min AC dielectric test, it offers SE3 natural/SBR rubber (60245 IEC 81 / YH) and oil/flame-retardant SE4 polychloroprene elastomer (60245 IEC 82 / YHF).
60245 IEC 81 (YH) & 60245 IEC 82 (YHF) Class 6 Rubber & Polychloroprene Welding Cable fulfills international EPC procurement schedules governed by IEC 60245-6 and Chinese national export standard GB/T 5013.6 across power-plant construction, petrochemical pipe fabrication, bridge erection and shipbuilding.
Overseas project bills of quantities frequently call out IEC code 60245 IEC 81 or 60245 IEC 82 alongside Chinese design-institute designations YH and YHF. Both types utilize IEC 60228 Class 6 extra-flexible copper conductors (maximum individual wire diameter 0.21 mm up to 95 mm²) wrapped in a thermal polyester/paper separator tape, yet their outer coverings target distinct site hazards: 60245 IEC 81 (YH) employs an SE3 natural/styrene-butadiene rubber sheath for dry mechanical resilience, whereas 60245 IEC 82 (YHF) upgrades to an SE4 polychloroprene (chloroprene / neoprene-equivalent) synthetic elastomer that resists mineral oil, weld spatter, ozone, sunlight and vertical flame propagation.
Select 60245 IEC 82 (YHF) whenever leads encounter machinery oil, damp outdoor yards or hot spatter; specify EN 50525-2-81 H01N2-D/E when +85 °C conductor rating (versus +65 °C/+60 °C standard IEC 60245-6 thermal basis) is required, or JIS C 3404 WCT for Japanese-standard replacements. Standard bulk drum MOQ 300 m with optional cold-crimped copper terminal lugs per drawing; lead time 7 to 45 working days.
Explore the welding cable range for related configurations.
60245 IEC 81 & 82 (YH / YHF) Cable Construction
Single-core Class 6 extra-flexible copper arc-welding secondary lead manufactured in accordance with IEC 60245-6 and GB/T 5013.6 in SE3 (YH) and SE4 polychloroprene (YHF) sheath grades.

| Component | Material and construction |
|---|---|
| 1. Class 6 Extra-Flexible Copper Conductor | Rope-bunched annealed bare copper wires per IEC 60228 Class 6 (max wire diameter 0.21 mm for 10–95 mm²; tinned copper optional for marine/humid environments). |
| 2. Polyester Film or Kraft Paper Separator | Heat-resistant separator tape prevents compound adhesion during continuous vulcanization and ensures clean stripping for lug barrels. |
| 3. Option A — SE4 Polychloroprene Elastomer Sheath (60245 IEC 82 / YHF) | Heavy-duty black chloroprene synthetic rubber compound (2.0 to 3.2 mm nominal wall) providing oil resistance, weather/UV stability and flame retardance. |
| 4. Option B — SE3 Rubber Sheath (60245 IEC 81 / YH) | Resilient natural/SBR elastomer covering for dry indoor workshops, structural steel yards and general mobile welder connections. |
60245 IEC 81 & 82 Designation & Compound Guide
- 60245 IEC 81 (Type YH): IEC 60245-6 arc-welding electrode cable with Class 6 copper conductor and SE3 general-purpose rubber covering
- 60245 IEC 82 (Type YHF): IEC 60245-6 arc-welding electrode cable with Class 6 copper conductor and SE4 polychloroprene (chloroprene) oil- and flame-retardant sheath
- SE3 / SE4 Sheath Compounds: IEC 60245 elastomer sheath classifications for normal rubber (SE3) versus polychloroprene or equivalent synthetic elastomer (SE4)
- 6 × D Minimum Bending Radius: Permissible dynamic handling and routing bend radius (6 times actual cable outer diameter)
- 1.0 kV / 5 min Dielectric Test: Mandatory finished-cable AC withstand voltage test applied for 5 minutes (secondary welding operating voltage up to 200 V DC / 100 V AC)
60245 IEC 81 & 82 (YH / YHF) Welding Applications
Designed for secondary electrode-holder and workpiece-return connections on AC/DC arc welders across industrial fabrication and field erection sites.

- Secondary welding leads connecting inverter, rectifier and rotary arc welders to manual electrode holders and earth return clamps.
- International EPC power-station, petrochemical refinery, cement-plant and steel-bridge construction projects specifying IEC 60245-6 or GB/T 5013.6 BOQ codes.
- Shipyard hull assembly, pressure-vessel manufacturing, heavy machinery workshops and pipeline welding stations (60245 IEC 82 / YHF recommended for oil & outdoor exposure).
- Bulk drum/coil export supply (MOQ 300 m) with optional custom cold-crimped copper lugs matched to welder DIN-plug or stud terminals.
60245 IEC 81/82 vs. H01N2-D/E & WCT Comparison
| Designation | Governing Standard | Sheath Compound | Max Conductor Temp | Oil & Flame Resistance |
|---|---|---|---|---|
| 60245 IEC 81 / YH | IEC 60245-6 / GB/T 5013.6 | SE3 natural / SBR rubber | +65 °C (+60 °C GB/T) | Dry general shop service (non-oil) |
| 60245 IEC 82 / YHF | IEC 60245-6 / GB/T 5013.6 | SE4 polychloroprene (PCP) | +65 °C (+60 °C GB/T) | Oil-resistant & IEC 60332-1-2 flame-retardant |
| H01N2-D / H01N2-E (WC 3465) | EN 50525-2-81 (HD 22.6) | EM5 cross-linked elastomer | +85 °C | Oil-, UV- & flame-retardant (+85 °C higher ampacity) |
| WCT (WC 2626) | JIS C 3404 | Natural rubber (WNCT = PCP) | +60 °C / +75 °C | Japanese OEM & shipyard secondary replacement |
Notice why 50 mm² YHF is rated 215 A at 100% duty whereas 50 mm² H01N2-D is rated 285 A: IEC 60245-6 / GB/T 5013.6 calculates ampacity at a conservative +60/+65 °C conductor limit rather than EN 50525-2-81's +85 °C EM5 compound limit.
60245 IEC 81 & 82 (YH / YHF) RFQ Checklist
- Exact standard code required on jacket print and tender BOQ: 60245 IEC 82 (YHF polychloroprene) or 60245 IEC 81 (YH general rubber).
- Nominal copper cross-section (10 mm² through 185 mm²) and conductor finish (standard bare Class 6 copper vs. tinned copper).
- Welder output current (A), duty cycle (100%, 80%, 60% or 40%) and single-way lead length if sizing confirmation is requested.
- Total meterage per cross-section (standard MOQ 300 m on export wooden drums or coils; lead time 7 to 45 working days).
- Optional custom cold-crimped copper terminal lug requirements (lug stud diameter and barrel dimensions per drawing).
Related selection resources
- Industrial & Custom Welding Cable Supplier Hub
- H01N2-D / H01N2-E EN 50525-2-81 100/100 V Welding Cable
- WCT JIS C 3404 Arc Welder Secondary Cable
- Welding Cable Size Chart: Amperage, Length & Duty Cycle
- CSP vs. CPE vs. Polychloroprene (CR) Rubber Jacket Selection Guide
60245 IEC 81 & 82 (YH / YHF) Welding Cable FAQ
What is the difference between 60245 IEC 81 (YH) and 60245 IEC 82 (YHF) welding cable?
60245 IEC 81 (YH) uses an SE3 natural/synthetic rubber covering for dry indoor welding, whereas 60245 IEC 82 (YHF) uses an SE4 polychloroprene (chloroprene) elastomer sheath that resists oil, grease, outdoor weathering, weld spatter and IEC 60332-1-2 flame propagation.
Why are 60245 IEC 82 (YHF) current ratings lower than H01N2-D for the same mm² size?
60 °C to 65 °C is the conservative maximum continuous conductor temperature specified in GB/T 5013.6 and IEC 60245-6 (giving 278 A for 50 mm² at 60% duty), whereas European H01N2-D rates its EM5 compound at +85 °C conductor temperature (365 A for 50 mm² at 60% duty).
What voltage test is performed on 60245 IEC 81 & 82 (YH / YHF) welding cables?
1,000 V AC for 5 minutes is applied to every finished cable length during routine factory inspection per IEC 60245-6; note that 1.0 kV is a dielectric withstand test value for secondary arc-welding leads, not a 1 kV primary power rating.
Can 60245 IEC 82 (YHF) be installed or flexed in sub-zero winter temperatures?
Yes, down to -20 °C in service once installed, provided the cable is preheated above 0 °C prior to uncoiling or dynamic laying when site ambient temperatures drop below freezing.
What is the MOQ for 60245 IEC 81 / 82 (YH / YHF) cable, and can you supply copper lugs?
300 m per cross-section is our standard export MOQ with a 7 to 45 working days lead time, and we can supply matched cold-crimped copper lugs to your terminal bolt drawing.
60245 IEC 81 & 82 Technical Specifications
60245 IEC 81 & 82 Key Engineering Highlights
- Exact IEC 60245-6 & GB/T 5013.6 compliance: Direct code match for international tender BOQs specifying 60245 IEC 81 (YH) or oil- and flame-retardant 60245 IEC 82 (YHF)
- Class 6 extra-fine copper (up to 0.21 mm wires): Multi-bunched annealed bare (or optional tinned YHR/YHFR) copper strands maintain low 6 × D bending radius across shop floors
- SE4 polychloroprene (YHF) vs SE3 rubber (YH): Choose SE4 chloroprene synthetic elastomer (YHF) for oil, grease, weld spatter and outdoor UV, or SE3 rubber (YH) for dry general fabrication
- 1,000 V / 5 min routine AC dielectric test: Every production drum passes 5-minute 1.0 kV AC finished-cable voltage withstand testing and 20 °C DC conductor resistance verification
- 300 m bulk MOQ & matched copper lugs: Supplied in 300 m minimum bulk drums/coils (7 to 45 working days) with optional custom cold-crimped copper lugs per terminal drawing
| Parameter | Value |
|---|---|
| Rated voltage | Secondary arc-welding circuit service up to 100 V AC and 200 V DC peak open-circuit; routine finished-cable test 1,000 V AC for 5 minutes |
| Operating temperature range | -20 °C to +45 °C ambient with +65 °C max continuous conductor temperature per IEC 60245-6 (preheat cable before flexing below 0 °C) |
| Conductor construction | IEC 60228 Class 6 extra-flexible annealed bare copper (maximum single-wire diameter 0.21 mm on 10 to 95 mm²; tinned option available) |
| Outer sheath options | SE4 black polychloroprene oil- and flame-retardant synthetic elastomer (60245 IEC 82 / YHF) or SE3 rubber compound (60245 IEC 81 / YH) |
| Minimum bending radius | 6 × cable outer diameter for mobile shop-floor handling and fixed welder lead routing |
| Minimum order and lead time | 300 m minimum order quantity per cross-section; custom manufacturing lead time 7 to 45 working days (cold-crimped copper lugs optional) |
60245 IEC 81 (YH) & 60245 IEC 82 (YHF) Complete Size & Duty-Cycle Schedule
| Model & Size (mm²) | Max Wire Ø (mm) | Nominal Sheath Wall (mm) | Overall OD Range (mm) | Approx. Weight (kg/km) | Max DC R @20 °C (Ω/km) | Ampacity 100% / 80% / 60% / 40% (A) | Bulk MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| 60245 IEC 82 (YHF) 1×10 | 0.21 | 2.0 | 7.7–9.7 | 165 | 1.91 | 70 / 78 / 90 / 110 | 300 m | Request this size |
| 60245 IEC 82 (YHF) 1×16 | 0.21 | 2.0 | 8.8–11.0 | 236 | 1.16 | 86 / 96 / 111 / 136 | 300 m | Request this size |
| 60245 IEC 82 (YHF) 1×25 | 0.21 | 2.0 | 10.1–12.7 | 322 | 0.758 | 135 / 151 / 174 / 213 | 300 m | Request this size |
| 60245 IEC 82 (YHF) 1×35 | 0.21 | 2.0 | 11.4–14.2 | 432 | 0.536 | 170 / 190 / 220 / 269 | 300 m | Request this size |
| 60245 IEC 82 (YHF) 1×50 | 0.21 | 2.2 | 13.2–16.5 | 593 | 0.379 | 215 / 240 / 278 / 340 | 300 m | Request this size |
| 60245 IEC 82 (YHF) 1×70 | 0.21 | 2.4 | 15.3–19.2 | 817 | 0.268 | 265 / 296 / 342 / 419 | 300 m | Request this size |
| 60245 IEC 82 (YHF) 1×95 | 0.21 | 2.6 | 17.1–21.4 | 1095 | 0.198 | 325 / 363 / 420 / 514 | 300 m | Request this size |
| 60245 IEC 82 (YHF) 1×120 | 0.31 | 2.8 | 19.2–24.0 | 1365 | 0.156 | 385 / 430 / 497 / 608 | 300 m | Request this size |
| 60245 IEC 82 (YHF) 1×150 | 0.31 | 3.0 | 21.1–26.4 | 1680 | 0.126 | 445 / 498 / 574 / 703 | 300 m | Request this size |
| 60245 IEC 82 (YHF) 1×185 | 0.51 | 3.2 | 23.1–28.9 | 2050 | 0.102 | 510 / 570 / 658 / 806 | 300 m | Request this size |
Dimensional ranges and 100%/80%/60%/40% duty-cycle current capacities follow IEC 60245-6 / GB/T 5013.6 (5-minute duty-cycle reference); both 60245 IEC 81 (YH SE3) and 60245 IEC 82 (YHF SE4 polychloroprene) share identical outer diameter envelopes.
Manufactured to IEC 60245-6 and GB/T 5013.6 technical specifications with full factory inspection report (CoC, DC resistance & 1.0 kV/5 min HV test). Sequential meter marking applied as standard.
ASCII part references for BOM and ERP entry: TF-YHF-1x10, TF-YHF-1x16, TF-YHF-1x25, TF-YHF-1x35, TF-YHF-1x50, TF-YHF-1x70, TF-YHF-1x95, TF-YHF-1x120, TF-YHF-1x150, TF-YHF-1x185, TF-YH-1x25, TF-YH-1x35, TF-YH-1x50, TF-YH-1x70, TF-YH-1x95.
60245 IEC 81 & 82 Standards & Test References
| Standard or specification | Application |
|---|---|
| IEC 60245-6 | International standard for rubber insulated arc-welding electrode cables (types 60245 IEC 81 normal rubber and 60245 IEC 82 polychloroprene). |
| GB/T 5013.6 | Equivalent national technical specification for YH (SE3) and YHF (SE4) flexible arc-welding machine cables. |
| IEC 60228 (Class 6) | Extra-flexible annealed copper conductor stranding and maximum 20 °C DC resistance requirements. |
| IEC 60332-1-2 | Single vertical insulated wire/cable flame-propagation test applicable to SE4 polychloroprene 60245 IEC 82 (YHF). |
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
H01N2-D & H01N2-E (NSLFFÖU) 100/100 V Rubber Arc Welding Cable (EN 50525-2-81, 10–240 mm²)
A related cable option for a different application or duty profile.
View productWCT Welding Cable for Arc Welder Secondary Leads (JIS C 3404, 14–200 mm²)
A related cable option for a different application or duty profile.
View product0361TQ BS 638 Part 4 100 V EPR/CSP (HOFR) Flexible Arc Welding Cable (16–240 mm²)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.