A304287 & OEH Subsea BOP MUX Control & IWOCS Intervention Electro-Optical Umbilical Cable
A304287, A304818, A305532 and OEH-series subsea BOP MUX (Blowout Preventer Multiplex) control and IWOCS (Intervention Workover Control System) umbilicals integrate redundant power conductors, low-attenuation screened signal pairs/quads, laser-welded FIMT optical fibres and optional 345 to 1,035 bar thermoplastic hydraulic/chemical hoses inside armoured HDPE, TPE or polyurethane packages (27.94 to 161 mm OD, 80 to 445 kN).
A304287, A304818, A305532, A305605 and OEH-series subsea BOP MUX control and IWOCS intervention umbilicals deliver sub-second safety-critical valve actuation, subsea control pod power and real-time pressure/temperature diagnostics between semi-submersibles, drillships, light well intervention vessels and deepwater blowout preventer or subsea tree stacks.
Beyond 600 to 1,000 m water depth, purely hydraulic pilot lines suffer unacceptable pressure-wave lag and excessive bundle diameter. Subsea Multiplex (MUX) BOP control replaces pilot hoses with dual redundant Yellow Pod and Blue Pod armoured electro-optical umbilicals (typically 27.94 mm / 1.10 in to 38.10 mm / 1.50 in OD, 80 to 445 kN breaking strength) carrying 8 to 28 power, solenoid and backup instrumentation conductors alongside 62.5/125 µm multimode or 9/125 µm single-mode optical fibres in stainless-steel FIMT tubes—activating subsea solenoid pilot valves instantaneously. For open-water riserless or riser-based well workovers, OEH0117, OEH0227 and OEH0246 IWOCS umbilicals combine 12 to 50 electrical cores and SM FIMTs with 8 to 19 methanol-washed PA11 / fluoropolymer high-pressure hoses (345, 690 and 1,035 bar) inside lightweight synthetic fibre strength braids.
Specify A304287 (38.10 mm, 445 kN TPE), A304818 (38.10 mm, 28C PE, 276 kN) or A305532 (29.97 mm, 22C HDPE, 400 kN) for drillship and semi-submersible BOP MUX reels and topside moonpool jumpers, or select OEH0117 / OEH0227 / OEH0246 for subsea tree installation and IWOCS reeler spreads. For pure ROV lift cables see our RM-Series ROV Main-Lift Umbilicals, or for smaller electro-hydraulic work-pack bundles see our OMB Subsea Hybrid Umbilicals.
Explore the oil, gas and petrochemical cable range for related configurations.
A304287 & OEH Subsea BOP MUX & IWOCS Multi-Layer Umbilical Construction
TEBAOFLEX manufactures both steel-armoured marine-riser BOP MUX electro-optical cables (27.94 to 38.10 mm OD) and synthetic-reinforced IWOCS electro-hydraulic intervention umbilicals (117 to 161 mm OD) with full longitudinal water-blocking against deepwater hydrostatic heads up to 3,000–4,000 m.

| Component | Material and construction |
|---|---|
| 1. Redundant Pod Power & Solenoid Feed Conductors | Stranded tinned copper power and earth conductors (1.34 mm², 2.5 mm², 6.0 mm² and 10.0 mm² / 16 to 8 AWG, rated 600/1,000 V to 1.8/3.0 kV) supplying dual subsea MUX pods, subsea electronics modules (SEM) and emergency backup circuits. |
| 2. Individually Screened Low-Delay Telemetry Pairs / Quads | Low-capacitance polyolefin/XLPE-insulated twisted pairs and star-quads (0.50 to 1.5 mm²) with 100% Al/PET foil + tinned copper drain/braid shields preventing power switching transients from corrupting MUX command frames. |
| 3. Laser-Welded FIMT Optical Elements (SMF & 62.5/125 µm MMF) | Gel-filled 316L stainless-steel tubes housing 62.5/125/245 µm graded-index multimode fibres (A304287, A304763, A304862, A305605) or up to 6 x 3 single-mode ITU-T G.652.D/G.657.A1 fibres (OEH0246) for redundant high-speed pod communication. |
| 4. Optional IWOCS High-Pressure Hydraulic & Chemical Hoses (OEH Series) | Collapse-resistant methanol-washed PA11 or co-extruded fluoropolymer core tubes (1/4 in, 3/8 in, 1/2 in, 5/8 in and 1 in ID) reinforced with high-tensile aramid or spiral steel wire for 345 bar (5,000 psi), 690 bar (10,000 psi) and 1,035 bar (15,000 psi) working pressure. |
| 5. Torque-Balanced Steel Wire or Synthetic Aramid Armour + HDPE/TPE/PUR Sheath | Contra-helical galvanized steel wire armour plus abrasion-resistant HDPE, PE or TPE outer jackets on A304/A305 BOP MUX cables (80 to 445 kN), or high-modulus synthetic aramid fibre reinforcement plus cut-resistant marine polyurethane outer sheath on OEH IWOCS umbilicals (100 to 300 kN). |

A304287 / A305532 / OEH BOP MUX & IWOCS Model Code Breakdown
- A304287 / A304818 (1.500 in): 38.10 mm deepwater drillship and semi-submersible BOP MUX control umbilicals rated 445 kN (13C + FIMT, TPE) and 276 kN (28C, PE)
- A305532 / A304485 / A305605: compact 27.94 to 30.99 mm (1.10 to 1.22 in) HDPE-jacketed armoured MUX control cables spanning 8 to 22 conductors and 80 to 400 kN breaking load
- BOP MUX (Yellow / Blue Pod): time-division multiplex electro-optical control architecture replacing slow hydraulic pilot lines with instant subsea solenoid actuation
- OEH0117 / OEH0227 / OEH0246: aramid-reinforced PUR IWOCS well-intervention umbilicals (117 to 161 mm OD) integrating 12–50 electrical cores, SM FIMTs and 345–1,035 bar hoses
A304287 & OEH Deepwater Drillship BOP Pod, Moonpool & IWOCS Applications
Deploy A304/A305 BOP MUX cables and OEH IWOCS umbilicals on 6th/7th-generation drillships, deepwater semi-submersibles, mobile offshore drilling units (MODUs) and light well intervention vessels.

- Dual redundant Yellow Pod and Blue Pod subsea Blowout Preventer (BOP) multiplex electro-optical control cables clamped along marine drilling risers to 3,000+ m water depth.
- Moonpool drag-chain jumpers, BOP reel-to-junction-box topside deck jumpers and short 50 to 500 m rig overhaul/test replacement cables matching existing 1.10 in to 1.50 in clamp and gland ODs.
- Intervention Workover Control System (IWOCS) open-water and in-riser umbilicals (OEH0117, OEH0227, OEH0246) operating subsea test trees, landing strings, stab-plates and chemical methanol/glycol injection.
- Subsea production manifold, PLET/PLEM and subsea boosting instrumentation/control umbilical jumpers requiring high-tensile HDPE/TPE armoured protection.
A304287 BOP MUX vs OEH IWOCS Umbilical vs Direct Hydraulic Bundle
| Subsea Drilling Control Line | Outer Diameter & Media | Command Response Time | Water-Depth & Rig Application |
|---|---|---|---|
| A304287 / A304818 BOP MUX Cable (this page) | 27.94–38.10 mm | Power + Screened Data + FIMT | < 1 second electrical/optical solenoid actuation | Deepwater semi-sub & drillship Yellow/Blue Pod BOP stacks (600–3,600+ m) |
| OEH0117 / OEH0227 / OEH0246 IWOCS (this page) | 117–161 mm | 12–50 Cu + SM FIMT + 8–19 Hoses (up to 1035 bar) | Instant electrical telemetry + direct high-pressure hydraulic supply | Riserless & in-riser subsea tree installation, workover & well intervention |
| Direct Pilot Hydraulic BOP Bundle | 75–140 mm | 40–60 pilot hydraulic tubes only | 15 to 45+ seconds hydraulic pressure-wave lag at depth | Shallow-water jack-up or < 400 m moored rigs where MUX pods are not fitted |
| OMB Compact Electro-Hydraulic Umbilical | 25–85 mm | 1–6 hoses + low-voltage control/video | Direct valve/tooling supply | ROV tooling skids, seabed trenchers, corers & diving work packs |
Always order matched outer-diameter tolerances when replacing one reel of a dual Yellow/Blue Pod BOP MUX pair so existing marine riser clamps and moonpool tensioner shoes grip evenly without jacket slip.
A304287 & OEH Subsea BOP MUX & IWOCS Umbilical RFQ Checklist
- System duty: marine-riser clamped subsea BOP MUX electro-optical cable (A304287, A304818, A305532), topside moonpool MUX jumper, or OEH IWOCS electro-hydraulic intervention umbilical.
- Target outer diameter & riser clamp / winch groove envelope (for example 1.500 in / 38.10 mm, 1.220 in / 30.99 mm, 1.100 in / 27.94 mm or 117–161 mm IWOCS).
- Electrical conductor schedule: pod power core count, cross-section (mm² or AWG), rated voltage, plus screened twisted pair/quad impedance and capacitance limits.
- Optical & hydraulic schedule: fibre count and mode (62.5/125 µm MMF or 9/125 µm SMF in FIMT) plus hose bore IDs and working pressures (345, 690 or 1,035 bar) for IWOCS.
- Breaking strength (kN or lbf), outer jacket polymer (HDPE, TPE or PUR), maximum water depth and continuous reel length (MOQ 50 m; lead time 7 to 45 working days).
Related selection resources
- Offshore oil, gas and subsea drilling cable product catalog
- Offshore drilling rig, BOP control and downhole cable selection guide
- Custom subsea umbilical and offshore engineering solutions
- OMB Series Subsea Electro-Hydraulic & Hose-Bundle Hybrid Umbilical Cable
- RS726 & RS935 Work-Class ROV, Pontoon & Winch Electro-Optical Umbilical & Deck Cable
- SBD-SWA Seabed Drilling Rig, Vibrocorer & Deep-Sea Mining Armoured Umbilical Cable
- Project record: 300 m / 41.0 mm OD spare offshore electro-optical umbilical & deck cable
- Engineering guide: matching replacement umbilical OD to existing clamps, grooves and sheaves
A304287 & OEH Subsea BOP MUX & IWOCS Umbilical Frequently Asked Questions
Why do deepwater drilling rigs use 1.5 inch (38.10 mm) A304287 or A304818 BOP MUX electro-optical cables instead of pilot hydraulic umbilicals?
38.10 mm (1.500 in) armoured MUX cables transmit time-division multiplexed electrical and optical commands to subsea Yellow/Blue pod solenoid pilot valves in milliseconds over 3,000 m water depths, eliminating the 20 to 60 second hydraulic pilot-fluid lag and massive hose-bundle weight of direct hydraulic BOP lines.
What is the difference between A304287 and A304818 1.500 inch subsea BOP MUX control cables?
445 kN (100,000 lbf) vs 276 kN (62,000 lbf) nominal breaking strength and hybrid electro-optical vs all-electrical core architecture: A304287 combines 13 copper power/signal cores with 62.5/125 µm optical fibres inside a TPE jacket, whereas A304818 houses 28 copper power, solenoid and backup instrumentation cores inside an abrasion-resistant PE jacket at the same 38.10 mm OD.
Why are OEH0117, OEH0227 and OEH0246 IWOCS umbilicals reinforced with synthetic aramid fibres rather than steel wire armour?
65% to 70% lower submerged weight in seawater (for example 3,965 kg/km in seawater vs 13,150 kg/km in air on 117 mm OEH0227) allows large 8-to-19-hose 690–1,035 bar well-intervention umbilicals to deploy from compact vessel reeler decks without exceeding moonpool sheave loads or heave-compensator limits.
Can TEBAOFLEX manufacture 50 m to 500 m BOP MUX deck jumpers and riser replacement sections matching existing 27.94 mm to 38.10 mm clamps?
Yes. TEBAOFLEX produces custom and 1:1 OD-matched BOP MUX cables and moonpool/topside deck jumpers from a 50 m minimum order quantity so existing marine riser clamps, slip-ring junction boxes and mechanical terminations require no hardware modification.
What are the minimum order quantity and manufacturing lead time for BOP MUX and IWOCS umbilical cables?
50 m minimum order quantity (MOQ), with a production lead time of 7 to 45 working days depending on screened MUX quad count, FIMT fibre tubes and 345–1,035 bar hose lay-up.
A304287, A304818 & OEH Dimensional, Optical, Hose & Breaking-Load Schedule
A304287 & MUX Key Diameter, Pod Channel, Pressure & Tensile Summary
- Yellow & Blue Pod BOP MUX builds: 1.10 in (27.94 mm), 1.18 in (29.97 mm), 1.22 in (30.99 mm) and 1.50 in (38.10 mm A304287 / A304818) marine riser-clamped and moonpool winch MUX cables
- Sub-second solenoid telemetry: Time-division multiplex power cores + low-capacitance individually foil-screened data pairs/quads + 62.5/125 µm MMF or 9/125 µm SMF FIMT tubes
- High-strength armoured HDPE / TPE: Contra-helical galvanized steel wire armour plus seawater-impervious HDPE, PE or TPE jackets delivering 80 kN to 445 kN (100,000 lbf) breaking load
- OEH IWOCS electro-hydraulic reels: OEH0227 (117 mm), OEH0117 (138 mm) and OEH0246 (161 mm) aramid-reinforced well-intervention umbilicals combining 12–50 cores, SM FIMTs and 345–1,035 bar hoses
- Rig spares & deck jumpers from 50 m: Minimum order quantity 50 m (including moonpool deck jumpers, riser test lengths and full 1,500 to 4,000 m deepwater BOP reels) in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 600/1,000 V AC/DC on pod power and control cores (up to 1.8/3.0 kV optional) and 300/500 V on screened MUX telemetry pairs |
| BOP MUX outer diameter and pull | 27.94 mm (1.10 in), 29.97 mm (1.18 in), 30.99 mm (1.22 in) and 38.10 mm (1.50 in) rated 80 kN to 445 kN (100,000 lbf) breaking load |
| IWOCS OEH hose and OD envelope | 117 mm (OEH0227), 138 mm (OEH0117) and 161 mm (OEH0246) integrating 8 to 19 hoses rated 345 bar, 690 bar and 1,035 bar WP |
| Electrical and optical channel mix | 8 to 50 copper power/earth/signal conductors plus 62.5/125 µm MMF or 9/125 µm SMF in laser-welded 316L stainless-steel FIMT units |
| Dynamic bend radius and supply | 12 to 15 x OD on A304/A305 MUX cables and 1,400 to 1,650 mm on OEH IWOCS reels, MOQ 50 m in 7 to 45 working days |
| Outer jacket materials | High-density polyethylene (HDPE), medium/linear PE, thermoplastic elastomer (TPE) or hydrolysis-resistant subsea polyurethane (PUR) |
| Hydrostatic & pressure safety | Water-blocked interstices for 3,000 m subsea immersion; IWOCS hoses proof-tested with 4:1 burst-to-working safety factor where specified |
A304287, A304818 & OEH Subsea BOP MUX & IWOCS Umbilical Specification Schedule
| Model & Subsea Duty | Nominal OD (mm | in) | Electrical Conductors | Optical Fibres / Hydraulic Hoses | Armour & Outer Jacket | Weight Air | Seawater (kg/km) | Breaking Load (kN | lbf) | Next step |
|---|---|---|---|---|---|---|---|
| A304763 / A304862 Compact BOP MUX | 27.94 | 1.100 | 8 Power & Screened MUX Cores | 62.5/125/245 µm MMF FIMT | No Hose | Contra-Helical SWA + HDPE / TPE | 1650–2100 | 1020–1450 | 80–205 | 18,000–45,000 | Request this size |
| A305605 16-Core Electro-Optical BOP MUX | 27.94 | 1.100 | 16 Power & Signal Cores | 62.5/125/245 µm MMF FIMT | No Hose | Contra-Helical SWA + Black HDPE | 1780 | 1150 | 98 | 22,000 | Request this size |
| A305532 High-Strength Drilling MUX | 29.97 | 1.180 | 22 Power, Solenoid & Signal Cores | Electrical MUX (Optional FIMT) | Heavy 2-Layer SWA + HDPE | 2950 | 2200 | 400 | 90,000 | Request this size |
| A304485 / A304739 Semi-Sub BOP MUX | 30.99 | 1.220 | 15 Power & Screened Telemetry Cores | Electrical MUX (Optional FIMT) | Contra-Helical SWA + HDPE | 1950–2480 | 1200–1720 | 107–231 | 24,000–52,000 | Request this size |
| A304287 Deepwater Electro-Optical BOP MUX | 38.10 | 1.500 | 13 Power (4P+5S+4 Aux) MUX Cores | 62.5/125 µm MMF or SMF FIMT | No Hose | Heavy Torque-Balanced SWA + TPE | 4460 | 3280 | 445 | 100,000 | Request this size |
| A304818 Drillship 28-Core BOP MUX | 38.10 | 1.500 | 28 Power, Solenoid & Backup Cores | Electrical MUX (Optional FIMT) | Contra-Helical SWA + PE Jacket | 3980 | 2820 | 276 | 62,000 | Request this size |
| OEH0227 IWOCS MUX Intervention Umbilical | 117.0 | 4.606 | 8x10 + 2x10E + 16x2.5 + 24x0.82 mm² | 2x3/8" 1035 bar + 2x1/4" 1035 bar + 4x1/4" 690 bar | High-Tensile Aramid + Subsea PUR | 13150 | 3965 | 100 | 22,500 | Request this size |
| OEH0117 / OEH0246 Deepwater IWOCS MUX | 138.0–161.0 | 5.43–6.34 | 12x2.5 mm² up to 44 Cores (1.34–6 mm²) | 6x3SM FIMT + 18–19 Hoses (1/4"–1", 345–690 bar) | High-Tensile Aramid + Subsea PUR | 18000–27390 | 5500–9730 | 100–300 | 22,500–67,400 | Request this size |
Standard 1.500 in (38.10 mm) A304287 and A304818 BOP MUX cables weigh approximately 4.0 to 4.46 kg/m (~3 lb/ft) in air and fit standard marine drilling riser MUX Saddle Clamps and slip-ring handling winches.
On OEH0117, OEH0227 and OEH0246 IWOCS umbilicals, minimum dynamic bend radius is 1,400 mm (OEH0117), 1,600 mm (OEH0227) and 1,650 mm (OEH0246), using synthetic aramid strength members to cut submerged weight by 65–70% compared with steel-armoured hose bundles.
Minimum order quantity is 50 m with a production lead time of 7 to 45 working days, supporting urgent moonpool deck jumpers, riser test loops, rig recertification spares and full 2,500 to 4,000 m Yellow/Blue Pod MUX reels.
ASCII part references: A304287; A304485; A304739; A304763; A304818; A304862; A305532; A305605; OEH0117; OEH0227; OEH0246; BOP-MUX-150; BOP-MUX-110.
A304287 & MUX Subsea Drilling Control Standards & Factory Test References
| Standard or specification | Application |
|---|---|
| ISO 13628-5 / API Spec 17E Subsea Umbilicals | Design, component lay-up, hydrostatic collapse, cyclic tension-bending and electrical/optical/hydraulic factory verification for MUX and IWOCS umbilicals. |
| ISO 13628-6 & API Spec 16D BOP Control Architecture | Low-latency multiplex electrical and optical command transmission between surface BOP control units and redundant Yellow/Blue subsea pods. |
| ITU-T G.652.D / IEC 60794 Optical & High-Pressure Hose Proofing | OTDR attenuation testing on 62.5/125 µm MMF and 9/125 µm SMF FIMT tubes plus 1.5x hydrostatic proof pressure testing on 345–1,035 bar IWOCS hoses. |
Certifications and document support
ISO 13628-5 — Petroleum and natural gas industries: Subsea umbilicals design and verification
ISO 13628-6 — Subsea production and multiplex control systems specification reference
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
OMB Series Subsea Electro-Hydraulic & Electro-Optical Hybrid Umbilical Cable (16OMB4, 16OMB6, 16OMB11, 19OMB40, 26OMB38, 27OMB24 & 35OMB22)
A related cable option for a different application or duty profile.
View productTF-TANKCRAWL Cargo Oil Tank (COT), FPSO & Petrochemical Sludge Crawler Antistatic Oil-Resistant Umbilical Cable
A related cable option for a different application or duty profile.
View productTF-RT Work-Class ROV TMS Excursion Tether & Subsea Intervention Cable (RT0084–RT0173 & 45XM301 Series)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.