2 kV DLO Cable Manufacturer | 12 AWG–1111 kcmil
DLO cable is a 2 kV single-conductor flexible power cable for diesel-electric locomotives, mining equipment, motor and generator leads, battery systems and demanding industrial power connections.
- Voltage: 2 kV DLO/HDFPC and 2 kV RHH/RHW-2; CSA RW90 reference by listed construction.
- Conductor: rope-lay Class I tinned annealed copper.
- Insulation: thermoset EPR for 90°C wet or dry service.
- Jacket: black thermoset XL-CPE.
- Size range: 14 AWG through 1111.1 kcmil in the current TEBAOFLEX data.
- Selection inputs: load, route, ambient temperature, conductor grouping, terminal rating and required cable marking.
Send the AWG/kcmil size, voltage, length, quantity, equipment, installation method and documentation requirements for a technical quotation.
2 kV DLO Cable Manufacturer | 12 AWG–1111 kcmil
TEBAOFLEX manufactures 2 kV DLO cable from 12 AWG to 1111 kcmil for locomotive, mining, motor, generator, battery, UPS and industrial power applications.
Choose the conductor size from the actual load, installation method, ambient temperature, grouping, terminal rating and governing electrical rules. Fine-stranded DLO conductors also require compatible lugs or ferrules and the correct crimp tooling. DLO is not automatically interchangeable with welding cable, and it is not a continuous-reeling cable simply because it is flexible.
- Suitable for: flexible 2 kV single-conductor power links.
- Specify by: AWG/kcmil size, route, current basis, temperature and required marking.
- Confirm: termination system, wet/dry duty, tray or conduit requirements and documentation.
- Choose another cable when: the circuit needs multiple cores, shielding, armour or continuous drum reeling.
Browse the industrial cable range and use the dedicated DLO cable ampacity chart for installation-specific sizing guidance.
DLO Cable Supply Range
| Buyer needs | TEBAOFLEX |
|---|---|
| Voltage | 2 kV |
| Size range | 12 AWG–1111 kcmil |
| Conductor | Tinned copper |
| Insulation | EPDM |
| Jacket | CPE |
| Standard markings | By approved size/scope |
| Jacket colors | Project options |
| Cut lengths | Available |
| Reel packing | Available |
| Custom marking | Available |
| Documentation | By project |
DLO Cable Supply Range
DLO cable price depends on conductor size, copper content, ordered length, certification/marking requirements, packing and destination. For a current quotation, send the required AWG/kcmil size, total length, quantity and destination country.
DLO Cable Construction
The DLO cable build combines a fine-stranded power conductor with separate thermoset insulation and jacket layers. This differs from a single-layer welding lead and gives the buyer a defined 2 kV power-cable construction with size-dependent building-wiring and tray-use markings.| Layer | Verified construction | Buyer value |
|---|---|---|
| Conductor | Flexible rope-lay Class I tinned annealed copper, manufactured using bunch-stranded components | Supports routing through compact locomotive, equipment and power-distribution layouts; tin coating assists corrosion control at the conductor surface. |
| Separator / binder | Non-hygroscopic separator tape over the conductor | Helps prevent the thermoset insulation from penetrating the fine strands and supports clean preparation for termination. |
| Insulation | Black thermoset ethylene propylene diene monomer (EPR) | Provides the primary 2 kV dielectric layer and supports 90°C operation in wet or dry locations. |
| Outer jacket | Thermoset chlorinated polyethylene (XL-CPE), black as standard; other colours by order | Provides resistance to oil, sunlight, abrasion, heat, flame exposure and routine industrial handling. |
| Identification | Surface, indent or sequential marking options showing the ordered model, size, voltage and applicable approval marks | Allows receiving inspectors and installers to verify that the delivered cable matches the approved submittal. |
Termination of the Fine-Stranded Conductor
Use compression lugs, ferrules or connectors specifically qualified for fine-stranded Class I/DLO conductors. A lug intended only for conventional building-wire stranding may not capture every strand or maintain the intended contact pressure. Strip the insulation without nicking or splaying the conductor, follow the connector manufacturer's die and crimp sequence, and verify the completed termination against the project procedure.DLO Cable Applications
DLO cable is selected where a single flexible power conductor must carry substantial current through compact equipment, exposed industrial routes or connections that need easier handling than conventional rigidly stranded power cable.- Diesel-electric locomotives, railway vehicles and transit-car power wiring.
- Mining, drilling, earth-moving and other electrically driven industrial equipment.
- Flexible motor leads, generator leads, transformer connections and switchgear links.
- UPS systems, battery banks, energy-storage equipment and standby-power connections.
- Wind-turbine generator power leads and industrial plant power connections.
- Wet or dry conduit, duct and trough routes when the ordered marking and local electrical rules permit.
- Cable-tray installations for 1/0 AWG and larger when the delivered cable carries the required CT-use and flame-test marking.
Selection Boundaries
DLO describes a flexible single-conductor cable family; it does not by itself approve every installation. Confirm the local electrical code, authority having jurisdiction, conductor ampacity, terminal temperature rating, grouping and ambient-temperature derating, and the exact sheath marking before installation. Use a purpose-designed reeling cable for continuous drum duty and a multi-core, screened or armoured cable where the circuit or mechanical risk requires those features.DLO Cable Is Not Automatically Interchangeable with Welding Cable
Welding cable is normally intended for welder secondary circuits. Substitution in either direction must be based on the voltage rating, insulation system, approved use, flame performance, environmental exposure and termination method—not conductor flexibility alone.DLO Cable Specifications
This data sheet describes the TEBAOFLEX 2000 V DLO construction with EPR insulation and an XL-CPE jacket. Dimensions and weights below are nominal or approximate values from the current DLO data sheet; confirm the ordered size, marking and production tolerances with the quotation.| Size | Strand | Conductor OD | Insulation | Jacket | Overall diameter | Approx. weight |
|---|---|---|---|---|---|---|
| 14 AWG | 19/.0147 | 1.8 mm | 1.1 mm | 0.4 mm | 5.1 mm | 45 kg/km |
| 12 AWG | 19/.0185 | 2.2 mm | 1.1 mm | 0.4 mm | 5.6 mm | 58 kg/km |
| 10 AWG | 27/24 | 3.0 mm | 1.1 mm | 0.4 mm | 6.4 mm | 83 kg/km |
| 8 AWG | 37/24 | 3.7 mm | 1.4 mm | 0.8 mm | 8.3 mm | 129 kg/km |
| 6 AWG | 61/24 | 4.8 mm | 1.5 mm | 0.8 mm | 9.7 mm | 195 kg/km |
| 4 AWG | 105/24 | 6.7 mm | 1.5 mm | 0.8 mm | 11.7 mm | 301 kg/km |
| 2 AWG | 158/24 | 8.0 mm | 1.5 mm | 0.8 mm | 13.0 mm | 424 kg/km |
| 1 AWG | 224/24 | 9.5 mm | 2.0 mm | 1.1 mm | 16.3 mm | 621 kg/km |
| 1/0 AWG | 280/24 | 11.0 mm | 2.0 mm | 1.1 mm | 17.8 mm | 735 kg/km |
| 2/0 AWG | 329/24 | 11.8 mm | 2.0 mm | 1.1 mm | 18.5 mm | 874 kg/km |
| 3/0 AWG | 456/24 | 13.6 mm | 2.0 mm | 1.1 mm | 20.3 mm | 1069 kg/km |
| 4/0 AWG | 551/24 | 14.8 mm | 2.0 mm | 1.1 mm | 21.3 mm | 1258 kg/km |
| 262.6 kcmil | 650/24 | 15.7 mm | 2.3 mm | 1.7 mm | 23.9 mm | 1563 kg/km |
| 313.3 kcmil | 777/24 | 17.0 mm | 2.3 mm | 1.7 mm | 25.3 mm | 1778 kg/km |
| 373.7 kcmil | 925/24 | 18.7 mm | 2.3 mm | 1.7 mm | 26.9 mm | 2060 kg/km |
| 444.4 kcmil | 1110/24 | 20.0 mm | 2.3 mm | 1.7 mm | 28.2 mm | 2432 kg/km |
| 535.3 kcmil | 1332/24 | 22.3 mm | 2.3 mm | 1.7 mm | 30.5 mm | 2865 kg/km |
| 646.4 kcmil | 1609/24 | 24.4 mm | 2.3 mm | 1.7 mm | 32.8 mm | 3433 kg/km |
| 777.7 kcmil | 1924/24 | 26.8 mm | 2.3 mm | 1.7 mm | 35.1 mm | 4060 kg/km |
| 929.9 kcmil | 2318/24 | 31.2 mm | 2.3 mm | 1.7 mm | 39.6 mm | 5313 kg/km |
| 1111.1 kcmil | 2745/24 | 33.7 mm | 2.9 mm | 2.4 mm | 44.9 mm | 6298 kg/km |
DLO Cable Standards and Test References
The supplied DLO product data names the following standards, approval and test references for the EPR/XL-CPE construction. Required sheath markings, certificate copies, test reports and inspection documents should be stated in the purchase specification.| Reference | Relationship stated in the supplied product data |
|---|---|
| UL 2806 | Heavy Duty Flexible Power Cable (HDFPC-DLO), 2 kV. |
| UL 44 | Thermoset-insulated RHH/RHW-2 power cable reference. |
| CSA C22.2 No. 38 | RW90 thermoset-insulated cable reference. |
| CSA C22.2 No. 230 | Tray-cable reference for the listed DLO constructions. |
| ASTM B33 and ASTM B172 | Tinned annealed copper wire and rope-lay stranded copper conductor references. |
| ICEA S-95-658 / NEMA WC 70 | Nonshielded power cable rated 2,000 V or less. |
| UL 1685 and IEEE 1202 / FT4 | Vertical-tray flame-test references named for listed constructions. |
| MSHA approval | Flame-resistant mining-cable approval named in the supplied product data. |
Project Documentation
- Confirm the required voltage, size and approval markings on the purchase specification.
- Request routine-test, conductor, insulation, jacket and dimensional inspection records when required.
- State any third-party inspection, witness testing, drum schedule, custom marking or packing requirement before production.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type W Round 4/C 2000V Mining Cable
A related cable option for a different application or duty profile.
View productWCT Welding Cable for Arc Welder Secondary Leads
A related cable option for a different application or duty profile.
View productSOOW Cable 600V for Heavy-Duty Portable Power
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.