MINING & TUNNELING CABLES TEBAOFLEX

SHD-GC Cable 2kV-25kV Mining Power Cable

SHD-GC cable is a shielded round portable mining power cable with grounding and ground-check conductors for heavy mobile equipment.

  • Voltage classes: 2kV, 5kV, 8kV, 15kV and 25kV
  • Construction: Flexible tinned copper, EPR insulation and composite shielding
  • Grounding: Grounding conductors plus an insulated ground-check conductor
  • Jacket options: CPE or TPU by project duty
  • Size references: Voltage-dependent ranges from 6 AWG to 500 kcmil; see Specifications
  • Applications: Miners, loaders, drills, shovels, draglines, dredges, conveyors and pumps
Product information
SKU
SHD-GC Cable 2-25 kV
Brand
TEBAOFLEX
Product overview

SHD-GC Cable for 2kV to 25kV Mining Power

SHD-GC cable is a shielded round portable mining power cable for mobile and semi-mobile equipment that needs power conductors, grounding conductors and a ground-check conductor in one heavy-duty construction. TEBAOFLEX supplies the product family for 2kV, 5kV, 8kV, 15kV and 25kV duties. Cable schedules may also write the name as SHD GC cable, Type SHD-GC, SHD-GC mining cable or cable SHD-GC.

The 2kV construction covers shielded portable power requirements that should not be selected only by comparison with Type G-GC cable or Type W. Higher-voltage configurations serve demanding mining equipment where shielding, grounding continuity, mechanical protection and a rugged jacket are central to the specification. Sizes run from 6 AWG to 500 kcmil at 2kV and 5kV, 4 AWG to 500 kcmil at 8kV, 2 AWG to 4/0 AWG at 15kV, and 1 AWG to 4/0 AWG at 25kV.

Typical construction uses flexible tinned-copper conductors, EPR insulation, conductor and insulation shielding, grounding conductors, an insulated ground-check conductor and an extra-heavy-duty jacket. CPE and TPU jacket options can be reviewed against abrasion, impact, oil, weather, water and low-temperature exposure.

Use this page as the SHD GC cable specs and quotation reference. Before ordering, confirm system voltage, conductor size, cable length, equipment, route movement, bend radius, jacket exposure and required approval documentation. Compare the Mining & Tunneling Cables range or use the SHD-GC vs Type G-GC vs Type W guide when the cable type is not yet fixed.

SHD-GC combines screened mining power, grounding and a ground-check conductor in one portable cable. A flexible single-conductor EPR feeder has a different layout; see Type MV-105 flexible 5 kV and 15 kV cable. Check movement duty, the protection circuit and approval scope before selecting either construction.

Construction

SHD-GC Cable Construction

The exact layer thicknesses and conductor sizes change with voltage and cable size. The following construction describes the consolidated 2kV to 25kV product family and should be checked against the project cable schedule.
SHD-GC cable cross section with shield, grounding and ground-check conductor
SHD-GC cable cross section showing three shielded power conductors, grounding conductors and the yellow ground-check conductor.
LayerTypical constructionSelection purpose
Power conductorsAnnealed, flexible stranded tinned copperSupports repeated handling and corrosion resistance.
Conductor shieldSemi-conductive layer over each power conductorControls the electrical field at the conductor interface.
InsulationEthylene-propylene rubber (EPR), typically rated for 90°C conductor operationProvides dielectric performance with flexibility.
Insulation shieldSemi-conducting layer with composite tinned-copper/polyamide braid; coverage follows the selected designProvides shielding while retaining portable-cable flexibility.
Grounding conductorsFlexible tinned-copper grounding conductors laid in the intersticesProvides the equipment grounding path required by the circuit design.
Ground-check conductorYellow TPE-E or polypropylene insulated flexible tinned copperSupports ground-continuity monitoring; 1x8 AWG in most sizes, 1x10 AWG in 2 kV sizes from 6 AWG to 2 AWG, and 1x6 AWG from 250 to 500 kcmil.
Core assemblyFillers and binder/separator tape as required by the constructionMaintains a round profile and stable core lay.
Outer jacketExtra-heavy-duty CPE or project-specified TPU; two-layer or reinforced options availableSelected for abrasion, impact, oil, weather, water, torsion and temperature exposure.
Construction note: jacket compound, reinforcement, shield coverage and approval markings must be confirmed for the exact voltage, conductor size and order.

Type SHD-GC Conductor and Shield Architecture

  • Three Shielded Phase Conductors: Each EPR-insulated tinned-copper phase core incorporates a semiconductive conductor shield, semiconductive insulation shield and composite tinned-copper/polyamide braid shield from 2 kV through 25 kV.
  • Two Interstitial Grounding Conductors: Symmetrical flexible tinned-copper grounding conductors laid in two outer interstices to balance ground-return impedance.
  • Insulated Ground-Check Conductor (GC): Yellow polypropylene or TPE-E insulated pilot conductor in the third interstice for continuous ground-loop monitoring.
  • Selection Boundary: Specify Type SHD-GC when individual phase shielding is required (2–25 kV); select unshielded 2000 V Type G-GC cable only when the 2 kV circuit does not require shielded phase cores.
Applications

SHD-GC Mining Cable Applications

Type SHD-GC is selected when the route needs a shielded portable cable with grounding and ground-check continuity. Match the voltage and mechanical duty to the machine rather than treating every mining cable name as interchangeable.
Equipment or routeTypical selection focusImportant checks
Continuous miners and longwall systems2kV or project-specified shielded portable powerRoute movement, ground-check circuit, water, abrasion and cable handling.
Loaders, drills, jumbos and conveyorsFlexible trailing duty with repeated handlingVoltage, bend radius, pulling tension, run-over risk and jacket compound.
Shovels, draglines and dredgesHigher-voltage heavy mobile mining power8kV, 15kV or 25kV class, conductor size, route length and mechanical protection.
Pumps and temporary mine distributionShielded portable or semi-mobile powerWater exposure, installation method, voltage drop and termination system.
Cranes and shore-to-ship routesProject-specific flexible heavy-duty supplyReeling or suspended movement, torsion, travel speed and local rules.

Where a longwall shearer needs three unshielded control conductors alongside the shielded power cores, compare the Type SHD-PCG 2 kV mining power cable, which combines three shielded power, three control and one grounding conductor in a reinforced CPE jacket.

Selection boundaries

  • Do not substitute Type G-GC or Type W solely because the voltage is 2kV; first confirm whether the circuit requires a shielded SHD-GC construction.
  • Do not treat a standard bend-radius value as a drum-design approval. Send reel, sheave, roller and route data for moving systems.
  • MSHA, CSA or other approval language applies only when the exact supplied construction and marking are documented for the order.
For a broader application path, review Mining Cable Solutions. For a cable-family comparison, use the SHD-GC, Type G-GC and Type W guide.

What size is the ground-check conductor in SHD-GC cable?

The ground-check conductor in SHD-GC cable is 1x8 AWG in most sizes. Two exceptions follow the voltage class and power-conductor size: 2 kV cables from 6 AWG to 2 AWG use a 1x10 AWG ground-check conductor, and 2 kV, 5 kV and 8 kV cables from 250 to 500 kcmil use 1x6 AWG. The insulated ground-check conductor carries the monitoring circuit and is separate from the two grounding conductors, which grow with the power conductors, for example 2x1 AWG on a 3x4/0 AWG cable.

How do I choose between 8 kV and 15 kV SHD-GC cable?

The choice between 8 kV and 15 kV SHD-GC cable follows the system voltage, not the conductor size. The 8 kV class has 150 mils (3.8 mm) EPR insulation in sizes 4 AWG to 500 kcmil; the 15 kV class has 210 mils (5.3 mm) in sizes 2 AWG to 4/0 AWG. At 15 kV the same size is larger: 3x4/0 AWG measures 2.75 in (69.9 mm) at 8 kV and 3.05 in (77.5 mm) at 15 kV.

How is an SHD-GC cable size written in an RFQ?

An SHD-GC cable size is written as SHD-GC 3x4/0 AWG + 2x1 AWG + 1x8 AWG 8 kV: three 4/0 AWG shielded power conductors, two 1 AWG grounding conductors, one 8 AWG insulated ground-check conductor and the 8 kV voltage class. Rows in the 2 kV to 25 kV SHD-GC size tables follow this form wherever the grounding and ground-check sizes are given, so a row can be copied into a cable schedule or RFQ.

What are the dimensions of 25 kV SHD-GC mining cable?

25 kV SHD-GC mining cable runs from 3x1 AWG to 3x4/0 AWG with 260 mils (6.6 mm) EPR insulation and a 265 to 295 mils (6.7 to 7.5 mm) jacket. Overall diameter is 2.95 in (74.9 mm) to 3.50 in (88.9 mm), and ampacity is 191 A to 327 A at 90°C conductor temperature and 40°C ambient air. The SHD-GC range is suitable for mobile equipment such as shovels, draglines and dredges.

What is the minimum order quantity and lead time for SHD-GC cable?

The minimum order quantity for SHD-GC cable is 50 m, for standard and custom constructions. Typical lead time is 7–45 working days depending on size, construction and order details; the written quotation governs. Send the voltage class, conductor size and required length with the request so the quotation covers the exact construction.

Specifications

SHD GC Cable Specs

Product typeType SHD-GC shielded round portable mining power cable with ground check
Voltage classes2kV, 5kV, 8kV, 15kV and 25kV
Power conductorsThree flexible stranded tinned-copper conductors
InsulationEPR; typical maximum conductor temperature 90°C
ShieldingConductor shield plus insulation shield/composite tinned-copper and polyamide braid according to selected construction
Ground systemGrounding conductors plus one insulated ground-check conductor
JacketExtra-heavy-duty CPE or project-specified TPU
Minimum bend radius6 × overall cable diameter; confirm the moving-route, reel, sheave and roller design separately
Low-temperature reference-40°C for current rubber/CPE selections; TPU options may be reviewed for -50°C service
PackingProject drum length; 1000 ft and 500 m formats can be reviewed with the quotation

Voltage and conductor-size reference

The ranges below are the TEBAOFLEX SHD-GC sizes for each voltage class; availability of each size is confirmed with the quotation.
Voltage classConductor sizesAmpacity range shown
2kV6 AWG to 500 kcmil93 to 536 A
5kV6 AWG to 500 kcmil93 to 536 A
8kV4 AWG to 500 kcmil122 to 536 A
15kV2 AWG to 4/0 AWG164 to 325 A
25kV1 AWG to 4/0 AWG191 to 327 A
Selection note: ampacity, outside diameter, weight, conductor stranding, grounding/ground-check sizes and insulation/jacket thickness are voltage- and size-specific. Confirm the order data sheet and installation conditions before procurement.

2kV electrical data

SizeConductor strandsDC resistance at 25°C (Ω/1000 ft)Inductance (mH/1000 ft)Capacitance (µF/1000 ft)1 s short-circuit current (kA)Ampacity at 40°C ambient (A)
6 AWG1330.4360.1180.091.9093
4 AWG2590.2740.1070.113.03122
2 AWG2590.1720.1010.134.80159
2/0 AWG3230.08680.0920.169.64243
250 MCM6270.04660.0840.2118.16355
500 MCM12210.02330.0780.2836.18536
Data-use note: these are TEBAOFLEX nominal 2kV electrical production values. The order-specific data sheet issued with each quotation states the final resistance, ampacity, dimensions, short-circuit duty and installation limits.

SHD-GC cable sizes by voltage class

Each SHD-GC size below is written the way cable schedules and RFQs give it: three power conductors, two grounding conductors and one insulated ground-check conductor, followed by the voltage class; where the grounding and ground-check cells show a dash, those sizes are confirmed with the quotation. Dimensions are TEBAOFLEX nominal production values; insulation and jacket thickness are in mils (mm) and overall diameter in inches (mm).

To choose between the five voltage classes, compare insulation walls, overall diameter growth and ampacity in the SHD-GC voltage ratings guide.

SHD-GC 2 kV mining cable sizes

SHD-GC 2 kV cable comes in 11 sizes from 3x6 AWG to 3x500 kcmil, with overall diameters of 32.8–81.0 mm (1.29–3.19 in), insulation walls of 70–95 mil (1.8–2.4 mm) and ampacity of 93–536 A at 90°C conductor temperature and 40°C ambient air.

SHD-GC 2 kV cable sizes and dimensions; ampacity at 90°C conductor temperature and 40°C ambient air
Size identifierInsulation mil / mmJacket mil / mmOverall diameter in / mmGrounding conductorsGround-check conductorAmpacity at 40°C ambient (A)Next step
SHD-GC 3x6 AWG + 2x10 AWG + 1x10 AWG 2 kV70 / 1.8155 / 3.91.29 / 32.82x10 AWG1x10 AWG93Request this size
SHD-GC 3x4 AWG + 2x8 AWG + 1x10 AWG 2 kV70 / 1.8155 / 3.91.40 / 35.62x8 AWG1x10 AWG122Request this size
SHD-GC 3x2 AWG + 2x6 AWG + 1x10 AWG 2 kV70 / 1.8170 / 4.31.59 / 40.42x6 AWG1x10 AWG159Request this size
SHD-GC 3x1 AWG + 2x5 AWG + 1x8 AWG 2 kV80 / 2.0190 / 4.81.76 / 44.72x5 AWG1x8 AWG184Request this size
SHD-GC 3x1/0 AWG + 2x4 AWG + 1x8 AWG 2 kV80 / 2.0190 / 4.81.86 / 47.22x4 AWG1x8 AWG211Request this size
SHD-GC 3x2/0 AWG + 2x3 AWG + 1x8 AWG 2 kV80 / 2.0205 / 5.22.00 / 50.82x3 AWG1x8 AWG243Request this size
SHD-GC 3x3/0 AWG + 2x2 AWG + 1x8 AWG 2 kV80 / 2.0205 / 5.22.13 / 54.12x2 AWG1x8 AWG279Request this size
SHD-GC 3x4/0 AWG + 2x1 AWG + 1x8 AWG 2 kV80 / 2.0220 / 5.62.31 / 58.72x1 AWG1x8 AWG321Request this size
SHD-GC 3x250 kcmil + 2x1/0 AWG + 1x6 AWG 2 kV95 / 2.4220 / 5.62.51 / 63.82x1/0 AWG1x6 AWG355Request this size
SHD-GC 3x350 kcmil + 2x2/0 AWG + 1x6 AWG 2 kV95 / 2.4235 / 6.02.81 / 71.42x2/0 AWG1x6 AWG435Request this size
SHD-GC 3x500 kcmil + 2x4/0 AWG + 1x6 AWG 2 kV95 / 2.4265 / 6.73.19 / 81.02x4/0 AWG1x6 AWG536Request this size

The first row of this table, 3x6 AWG + 2x10 AWG + 1x10 AWG with an orange TPU jacket, was produced and shipped to a distributor in Peru in August 2026; see SHD-GC 2 kV 3×6+2×10+1×10 AWG Shielded Mining Cable with an Orange TPU Jacket for a Distributor in Peru.

SHD-GC 5 kV mining cable sizes

SHD-GC 5 kV cable comes in 12 sizes from 3x6 AWG to 3x500 kcmil, with overall diameters of 39.6–84.1 mm (1.56–3.31 in), insulation walls of 110–120 mil (2.8–3.0 mm) and ampacity of 93–536 A at 90°C conductor temperature and 40°C ambient air.

SHD-GC 5 kV cable sizes and dimensions; ampacity at 90°C conductor temperature and 40°C ambient air
Size identifierInsulation mil / mmJacket mil / mmOverall diameter in / mmGrounding conductorsGround-check conductorAmpacity at 40°C ambient (A)Next step
SHD-GC 3x6 AWG + 2x10 AWG + 1x8 AWG 5 kV110 / 2.8185 / 4.71.56 / 39.62x10 AWG1x8 AWG93Request this size
SHD-GC 3x4 AWG + 2x8 AWG + 1x8 AWG 5 kV110 / 2.8185 / 4.71.68 / 42.72x8 AWG1x8 AWG122Request this size
SHD-GC 3x2 AWG + 2x6 AWG + 1x8 AWG 5 kV110 / 2.8205 / 5.21.87 / 47.52x6 AWG1x8 AWG159Request this size
SHD-GC 3x1 AWG + 2x5 AWG + 1x8 AWG 5 kV110 / 2.8205 / 5.21.95 / 49.52x5 AWG1x8 AWG184Request this size
SHD-GC 3x1/0 AWG + 2x4 AWG + 1x8 AWG 5 kV110 / 2.8220 / 5.62.08 / 52.82x4 AWG1x8 AWG211Request this size
SHD-GC 3x2/0 AWG + 2x3 AWG + 1x8 AWG 5 kV110 / 2.8220 / 5.62.20 / 55.92x3 AWG1x8 AWG243Request this size
SHD-GC 3x3/0 AWG + 2x2 AWG + 1x8 AWG 5 kV110 / 2.8235 / 6.02.36 / 59.92x2 AWG1x8 AWG279Request this size
SHD-GC 3x4/0 AWG + 2x1 AWG + 1x8 AWG 5 kV110 / 2.8235 / 6.02.50 / 63.52x1 AWG1x8 AWG321Request this size
SHD-GC 3x250 kcmil + 2x1/0 AWG + 1x6 AWG 5 kV120 / 3.0250 / 6.42.69 / 68.32x1/0 AWG1x6 AWG355Request this size
SHD-GC 3x300 kcmil 5 kV120 / 3.0250 / 6.42.81 / 71.4——398Request this size
SHD-GC 3x350 kcmil + 2x2/0 AWG + 1x6 AWG 5 kV120 / 3.0265 / 6.72.95 / 74.92x2/0 AWG1x6 AWG435Request this size
SHD-GC 3x500 kcmil + 2x4/0 AWG + 1x6 AWG 5 kV120 / 3.0280 / 7.13.31 / 84.12x4/0 AWG1x6 AWG536Request this size

SHD-GC 8 kV mining cable sizes

SHD-GC 8 kV cable comes in 11 sizes from 3x4 AWG to 3x500 kcmil, with overall diameters of 49.3–90.4 mm (1.94–3.56 in), insulation walls of 150 mil (3.8 mm) and ampacity of 122–536 A at 90°C conductor temperature and 40°C ambient air.

SHD-GC 8 kV cable sizes and dimensions; ampacity at 90°C conductor temperature and 40°C ambient air
Size identifierInsulation mil / mmJacket mil / mmOverall diameter in / mmGrounding conductorsGround-check conductorAmpacity at 40°C ambient (A)Next step
SHD-GC 3x4 AWG + 2x8 AWG + 1x8 AWG 8 kV150 / 3.8205 / 5.21.94 / 49.32x8 AWG1x8 AWG122Request this size
SHD-GC 3x2 AWG + 2x6 AWG + 1x8 AWG 8 kV150 / 3.8220 / 5.62.12 / 53.82x6 AWG1x8 AWG159Request this size
SHD-GC 3x1 AWG + 2x5 AWG + 1x8 AWG 8 kV150 / 3.8220 / 5.62.21 / 56.12x5 AWG1x8 AWG184Request this size
SHD-GC 3x1/0 AWG + 2x4 AWG + 1x8 AWG 8 kV150 / 3.8220 / 5.62.32 / 58.92x4 AWG1x8 AWG211Request this size
SHD-GC 3x2/0 AWG + 2x3 AWG + 1x8 AWG 8 kV150 / 3.8235 / 6.02.46 / 62.52x3 AWG1x8 AWG243Request this size
SHD-GC 3x3/0 AWG + 2x2 AWG + 1x8 AWG 8 kV150 / 3.8250 / 6.42.62 / 66.52x2 AWG1x8 AWG279Request this size
SHD-GC 3x4/0 AWG + 2x1 AWG + 1x8 AWG 8 kV150 / 3.8250 / 6.42.75 / 69.92x1 AWG1x8 AWG321Request this size
SHD-GC 3x250 kcmil + 2x1/0 AWG + 1x6 AWG 8 kV150 / 3.8250 / 6.42.89 / 73.42x1/0 AWG1x6 AWG355Request this size
SHD-GC 3x300 kcmil 8 kV150 / 3.8265 / 6.73.04 / 77.2——398Request this size
SHD-GC 3x350 kcmil + 2x2/0 AWG + 1x6 AWG 8 kV150 / 3.8280 / 7.13.21 / 81.52x2/0 AWG1x6 AWG435Request this size
SHD-GC 3x500 kcmil + 2x4/0 AWG + 1x6 AWG 8 kV150 / 3.8295 / 7.53.56 / 90.42x4/0 AWG1x6 AWG536Request this size

The 3x4/0 AWG + 2x1 AWG + 1x8 AWG 8 kV row was produced as a 200 m length for Peru; see SHD-GC 8 kV 3×4/0+2×1+1×8 AWG Class 6 Mining Power Cable (200 m) for Peru.

SHD-GC 15 kV mining cable sizes

SHD-GC 15 kV cable comes in 6 sizes from 3x2 AWG to 3x4/0 AWG, with overall diameters of 61.2–77.5 mm (2.41–3.05 in), insulation walls of 210 mil (5.3 mm) and ampacity of 164–325 A at 90°C conductor temperature and 40°C ambient air.

SHD-GC 15 kV cable sizes and dimensions; ampacity at 90°C conductor temperature and 40°C ambient air
Size identifierInsulation mil / mmJacket mil / mmOverall diameter in / mmGrounding conductorsGround-check conductorAmpacity at 40°C ambient (A)Next step
SHD-GC 3x2 AWG + 2x6 AWG + 1x8 AWG 15 kV210 / 5.3235 / 6.02.41 / 61.22x6 AWG1x8 AWG164Request this size
SHD-GC 3x1 AWG + 2x5 AWG + 1x8 AWG 15 kV210 / 5.3235 / 6.02.52 / 64.02x5 AWG1x8 AWG187Request this size
SHD-GC 3x1/0 AWG + 2x4 AWG + 1x8 AWG 15 kV210 / 5.3250 / 6.42.64 / 67.12x4 AWG1x8 AWG215Request this size
SHD-GC 3x2/0 AWG + 2x3 AWG + 1x8 AWG 15 kV210 / 5.3250 / 6.42.73 / 69.32x3 AWG1x8 AWG246Request this size
SHD-GC 3x3/0 AWG + 2x2 AWG + 1x8 AWG 15 kV210 / 5.3265 / 6.72.90 / 73.72x2 AWG1x8 AWG283Request this size
SHD-GC 3x4/0 AWG + 2x1 AWG + 1x8 AWG 15 kV210 / 5.3265 / 6.73.05 / 77.52x1 AWG1x8 AWG325Request this size

SHD-GC 25 kV mining cable sizes

SHD-GC 25 kV cable comes in 5 sizes from 3x1 AWG to 3x4/0 AWG, with overall diameters of 74.9–88.9 mm (2.95–3.50 in), insulation walls of 260 mil (6.6 mm) and ampacity of 191–327 A at 90°C conductor temperature and 40°C ambient air.

SHD-GC 25 kV cable sizes and dimensions; ampacity at 90°C conductor temperature and 40°C ambient air
Size identifierInsulation mil / mmJacket mil / mmOverall diameter in / mmGrounding conductorsGround-check conductorAmpacity at 40°C ambient (A)Next step
SHD-GC 3x1 AWG + 2x5 AWG + 1x8 AWG 25 kV260 / 6.6265 / 6.72.95 / 74.92x5 AWG1x8 AWG191Request this size
SHD-GC 3x1/0 AWG + 2x4 AWG + 1x8 AWG 25 kV260 / 6.6265 / 6.73.05 / 77.52x4 AWG1x8 AWG218Request this size
SHD-GC 3x2/0 AWG + 2x3 AWG + 1x8 AWG 25 kV260 / 6.6280 / 7.13.20 / 81.32x3 AWG1x8 AWG249Request this size
SHD-GC 3x3/0 AWG + 2x2 AWG + 1x8 AWG 25 kV260 / 6.6280 / 7.13.33 / 84.62x2 AWG1x8 AWG286Request this size
SHD-GC 3x4/0 AWG + 2x1 AWG + 1x8 AWG 25 kV260 / 6.6295 / 7.53.50 / 88.92x1 AWG1x8 AWG327Request this size

Other SHD constructions

Fibre-optic, LED high-visibility, flat and CSA versions of SHD cable have their own pages:

Supply and ordering

  • Minimum order quantity: 50 m, for standard and custom constructions.
  • Typical lead time: 7–45 working days depending on size, construction and order details; the written quotation governs.
Standards

Standards, Testing and Order Documentation

Scope: TEBAOFLEX SHD-GC covers 2kV, 5kV, 8kV, 15kV and 25kV three-conductor constructions. Final markings and approval scope remain order-specific.
ReferenceHow it is usedScope note
ANSI/ICEA S-75-381 / NEMA WC 23058Portable and power-feeder cables for mines and similar applicationsCurrent designation; NEMA WC 58 is the former designation commonly found in existing specifications.
ASTM B33Tin-coated soft or annealed copper wireApplicable when the selected construction uses tin-coated copper covered by the referenced requirement.
ASTM B172Rope-lay-stranded copper conductorsConfirm conductor construction and edition on the order data sheet.
CAN/CSA C22.2 No. 96Canadian portable power cable standard referenceConfirm the exact construction, marking and certification evidence required by the order.
MSHA / CSA optionsProject- or market-specific approval and markingNo blanket approval is claimed. Availability must be confirmed for the exact voltage, size, jacket and supplied marking.

Colombia: RETIE references to SHD-GC cable

Colombia's electrical installation regulation, RETIE, issued by the Ministry of Mines and Energy (Resolution 40284 of 2026, Book 3), refers in Article 3.28.6.1 i to SHD-GC or similar portable power cables, insulated for at least 5 kV, for circuits of 1,000 to 4,600 V inside mines and their escape routes, and to 25 kV insulation for higher voltages.

Article 3.28.6.3 of the same regulation refers to SHD-GC or SHD-CGC cables for mobile mining equipment and requires them to be certified for mining use. Confirm the certification evidence required for a Colombian project before ordering.

Documentation available for review

  • Order-specific technical data sheet and cable construction drawing.
  • Routine electrical test report and agreed inspection records.
  • Cable marking, drum schedule, packing list and project documentation.
  • Applicable approval or compliance evidence only when included in the confirmed order scope.
Procurement note: send the existing cable marking, mine or equipment specification, voltage, conductor size, length, movement pattern and required documentation. TEBAOFLEX will review the requested construction before quotation.
Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.