AS/NZS Mining Cables: AS/NZS 1802 vs AS/NZS 2802 Type 209, 241, 245, 275 and 441 Selection Guide

Engineering guide to Australian and New Zealand AS/NZS mining cables, comparing AS/NZS 1802 underground coal 200-series (Type 209, 210, 240, 241, 241SF, 245, 245UF, 260, 275), AS/NZS 2802 surface and metalliferous 400-series (Type 409, 412, 440, 441, 450, 451, 455), and AS/NZS 1972 feeder cables.

AS/NZS mining cables are heavy-duty flexible elastomer power and reeling cables engineered with reference to joint Australian and New Zealand standards AS/NZS 1802, AS/NZS 2802, and AS/NZS 1972 to supply mobile and semi-fixed mining equipment under continuous earth-continuity and earth-fault protection. Selecting the right construction starts by separating the three standards by mine environment and cable duty: AS/NZS 1802 covers 200-series reeling and trailing cables for underground coal mines up to 11 kV, AS/NZS 2802 covers 400-series reeling and trailing cables for surface open-cut mines and underground metalliferous mines up to 33 kV, and AS/NZS 1972 covers Type 1 and Type 2S feeder cables for underground coal mine power distribution.

Within TEBAOFLEX’s mining and tunneling cables manufacturing program, nineteen Australian-standard cable types are built with reference to AS/NZS 1802, AS/NZS 2802, and AS/NZS 1972, pairing AS/NZS 1125 tinned flexible copper conductors with R-EP-90 or XR-EP-90 ethylene-propylene rubber insulation (AS/NZS 3808) and heavy-duty HD-85-PCP, XHD-85-PCP, or HD-90-CPE outer sheaths.

How Australian mining cable standards divide underground coal, open-cut, and feeder duty

Understanding Australian mining cable standards requires checking the regulatory boundary between gassy underground coal seams and non-coal or open-cut operations before comparing individual type numbers. Mine electrical safety frameworks overseen by state authorities such as the NSW Resources Regulator in New South Wales and WorkSafe Western Australia require trailing and reeling cables to match both the explosive-atmosphere classification of the mine and the earth-fault protection relay architecture of the supply substation.

Three core Australian and New Zealand standards govern the electrical and mechanical construction of flexible mining cables, supported by two companion material standards:

  1. AS/NZS 1802 (Underground coal mining reeling and trailing cables): Governs the 200-series flexible elastomer cables (Type 209, Type 210, Type 240, Type 241, Type 241SF, Type 245, Type 245UF, Type 260, and Type 275) from 1.1/1.1 kV up to 11/11 kV. Every AS/NZS 1802 construction is engineered around strict methane and coal-dust ignition mitigation, individual phase earth screening or pliable wire armour, and pilot-circuit interlocking so power is isolated immediately if a cable is crushed or severed.
  2. AS/NZS 2802 (Reeling and trailing cables for surface mines and metalliferous mines): Governs the 400-series elastomer cables (Type 409, Type 412, Type 440, Type 441.1 Class 2, Type 441 Class 1, Type 450, Type 451, and Type 455) from 1.1/1.1 kV up to 33/33 kV. Because open-cut iron ore, coal, bauxite, and hard-rock haul roads subject cables to extreme rock abrasion, high drum tension, and long high-voltage feeder runs for electric rope shovels and draglines, AS/NZS 2802 introduces Class 1 extra-heavy-duty XR-EP-90 / XHD-85-PCP compound pairings and voltage classes up to 22 kV and 33 kV.
  3. AS/NZS 1972 (Electric cables — Underground coal mines — Other than reeling and trailing): Covers semi-flexible feeder, flit-plug interconnection, and road-header or pump distribution cables (Mine Feeder Type 1, Type 2S, and Type 2S.3) that are hung along roadways or relocated periodically rather than wound dynamically onto mobile machine reels.
  4. AS/NZS 1125 and AS/NZS 3808 (Conductors and insulating/sheathing compounds): AS/NZS 1125 specifies the tinned annealed copper wire stranding (including flexible Class 5 and Class 6 constructions aligned with international conductor principles in IEC 60228:2023), while AS/NZS 3808 defines the thermal and mechanical grades for R-EP-90 and XR-EP-90 EPR insulation and HD-85-PCP, XHD-85-PCP, HD-90-CPE, and 5V-90 outer sheaths.
Comparison of AS/NZS 1802, AS/NZS 2802, and AS/NZS 1972 mining cable standards
Standard referenceDesignation seriesPrimary mine environmentVoltage range ($U_0/U$)Key construction and compound features
AS/NZS 1802200-series (Type 209, 210, 240, 241, 241SF, 245, 245UF, 260, 275)Underground coal mining mobile machinery (continuous miners, longwall shearers, shuttle cars, bolters, drills)1.1/1.1 kV to 11/11 kVAS/NZS 1125 tinned flexible copper; R-EP-90 insulation (90 °C continuous, 250 °C short-circuit); composite braid or semi-conductive elastomer screens; HD-85-PCP sheath (85 °C max Jacket)
AS/NZS 2802400-series (Type 409, 412, 440, 441.1, 441, 450, 451, 455)Open-cut surface mines (electric shovels, draglines, drills, mobile crushers) and underground metalliferous mines1.1/1.1 kV to 33/33 kVDivided into Class 2 (R-EP-90 / HD-85-PCP up to 22 kV) and Class 1 (XR-EP-90 / XHD-85-PCP extra-heavy-duty from 3.3 kV to 33 kV); polyaramid or open-weave reinforcement
AS/NZS 1972Mine Feeder Type 1, Type 2S, Type 2S.3Underground coal mine fixed and semi-portable roadway feeders, gate-end interconnects, and pumps1.1/1.1 kV (Type 1, Type 2S) and 3.3/3.3 kV (Type 2S.3)Type 1 uses V-90 PVC insulation and 5V-90 PVC sheath (C3 flame test); Type 2S / 2S.3 use R-EP-90 EPR insulation and black HD-90-CPE sheath (C1 flame test)

Decoding AS/NZS mining cable type numbers, screens, and earth-pilot geometry

Australian mining cable type numbers encode five construction choices: the mine sector (200-series vs 400-series), the phase-screening method (composite metallic/textile braid vs semi-conductive elastomer layer), the protective-earth conductor placement (screen-as-earth vs discrete interstitial earth cores), the number and position of pilot cores (1 central vs 3 interstitial vs 3 central extensible), and the nominal voltage suffix (.1, .3, .6, .11, .22, or .33).

Four-panel cross-section comparison of TEBAOFLEX AS/NZS 1802 Type 209, Type 241, Type 245UF, and AS/NZS 2802 Type 450 mining cables
Cross-sectional comparison across TEBAOFLEX Australian-standard mining cables: Type 209 (composite phase braid screen + 1 central pilot), Type 241/241SF (semi-conductive phase screen + 3 interstitial earths + 1 central pilot), Type 245/245UF (3 interstitial earths + 3 central extensible pilots for longwall shearers), and Type 450/451 (3.3–33 kV Class 1 with 2 interstitial earths + 1 interstitial pilot).

Composite metallic braid screens vs semi-conductive elastomer screens

Every screened AS/NZS 1802 and AS/NZS 2802 reeling or trailing cable surrounds each insulated phase core with a protective earth screen so that any rock crush, roof fall, or insulation breakdown produces a phase-to-earth fault before a high-energy phase-to-phase arc can develop. Australian standard mining cables implement this barrier in two distinct ways:

  • Composite tinned-copper and synthetic-yarn braid screens (Type 209, Type 210, Type 240, Type 260, Type 409, Type 440, Type 450, Type 451): Each R-EP-90 or XR-EP-90 insulated phase core is wrapped in a woven composite braid of tinned annealed copper wires and nylon, polyamide, or polyester filaments (AS/NZS 1802 / AS/NZS 2802). In Type 209, Type 210, Type 240, Type 409, and Type 440, the three metallic phase screens carry the full earth-fault return current directly and eliminate separate interstitial earth cores, keeping the cable outside diameter compact. In Type 450 and Type 451 (3.3–33 kV), composite phase screens work in parallel with two dedicated interstitial earth conductors to meet high-voltage fault ratings.
  • Semi-conductive elastomer phase screens with interstitial earth cores (Type 241, Type 241SF, Type 245, Type 245UF, Type 441.1, Type 441, Type 455): Instead of a metallic wire braid over each phase, the R-EP-90 or XR-EP-90 insulation is enclosed by a semi-conductive elastomeric barrier layer that maintains intimate electrical contact with three interstitial earth conductors laid in the outer interstices (2 interstitial earths in Type 455). Because eliminating the metallic wire braid over the phase cores removes wire-on-wire fretting during tight monospiral or level-wind reeling, semi-conductive screened cables (241, 245, 441, 455) are widely selected where high flexing cycles or broken screen wires would otherwise puncture the insulation.

Pilot core layouts (1 central vs 3 interstitial vs 3 central) and voltage suffixes

Pilot cores connect the gate-end box or field switch to a terminating diode or earth-continuity relay inside the mining machine, verifying earth loop integrity and disabling the contactor before power is applied:

  • Single central pilot (Type 209, Type 210, Type 241, Type 241SF, Type 275, Type 409, Type 441.1, Type 441): One extensible R-EP-90-covered pilot conductor sits on the neutral bending axis at the center of the three power cores. Placing the pilot in the center equalizes tension when the cable bends in any direction over sheaves or rollers.
  • Three interstitial pilots (Type 240, Type 440): When the three composite phase screens serve as the earth path and the center cradle is occupied by an elastomer profile, three insulated pilot cores sit in the outer interstices between the phase cores, providing extra control or monitoring channels.
  • Two interstitial earths + one interstitial pilot (Type 450, Type 451, Type 455): In high-voltage open-cut shovel and dragline cables (3.3 kV to 33 kV), three symmetrical outer interstices house two earth conductors and one pilot conductor (Type 451 uses a reduced-size pilot core for smaller pilot-circuit glands).
  • Three central extensible pilots (Type 245 and Type 245UF): Longwall shearers require multiple control and monitoring channels without sacrificing the three interstitial earth cores. Type 245 and Type 245UF group three extensible insulated pilot cores inside a central elastomeric core assembly surrounded by the three power cores and three semi-conductive-covered interstitial earths.
  • Voltage designation suffixes: The decimal number appended to the base type indicates the nominal system voltage in kilovolts ($U_0/U$): .1 = 1.1/1.1 kV, .3 = 3.3/3.3 kV, .6 = 6.6/6.6 kV, .11 = 11/11 kV, .22 = 22/22 kV, and .33 = 33/33 kV (for example, Type 241.1 is rated 1.1/1.1 kV, Type 245.3 UF is rated 3.3/3.3 kV, and Type 450.22 is rated 22/22 kV).

AS/NZS 1802 mining cable selection for underground coal mines (200-series)

Choosing an AS/NZS 1802 mining cable for an underground coal face depends on how the machine moves: handheld drilling, general flitting and trailing, monospiral shuttle-car reeling, or high-cycle longwall shearer cable-handler chains. The table below compares all nine AS/NZS 1802 constructions manufactured by TEBAOFLEX.

TEBAOFLEX AS/NZS 1802 200-series underground coal mining cables
TEBAOFLEX AS/NZS 1802 typeVoltage ratings ($U_0/U$) & power cross-sectionCore & earth-pilot geometryPhase screen & mechanical reinforcementPrimary underground coal mining equipment
Type 209 mining cable (209.1, 209.3, 209.6, 209.11)1.1/1.1 kV to 11/11 kV; 2.5–300 mm² (1.1 kV), 16–300 mm² (3.3–6.6 kV), 25–150 mm² (11 kV)3 power cores + 1 central extensible pilot (6.0–16 mm²); screens serve as earthTinned-copper / polyamide composite braid screen on each phase; open-weave braid under HD-85-PCP sheathGeneral underground coal mobile machines, drills, pumps, and continuous miners (6 × OD min bend radius)
Type 210 flexible rubber mining cable (Type 210.1)1.1/1.1 kV; 1.5 mm² and 2.5 mm² power cores3 power cores + 1 central EPR-covered pilot (1.5 mm² or 2.5 mm²); screens serve as earthComposite tinned-copper / polyester yarn braid screen (6.6 A/mm² fault rating); black HD-85-PCP sheathHand-held rotary boring machines and light underground coal face drills (20.4–22.3 mm OD; 4 × D min bend radius)
Type 240 underground coal mine cable (240.1, 240.3, 240.6, 240.11)1.1/1.1 kV to 11/11 kV; 2.5–300 mm²3 phase cores + 3 interstitial pilot cores; composite screens serve as earthTinned-copper / nylon composite braid screen on each phase; heavy-duty HD-85-PCP elastomer sheathGeneral underground coal mine trailing applications requiring 3 pilot circuits (excludes shuttle cars)
Type 241 mining cable (241.1, 241.3, 241.6, 241.11)1.1/1.1 kV to 11/11 kV; 6–300 mm² (1.1 kV), 16–300 mm² (3.3–6.6 kV), 25–150 mm² (11 kV)3 power cores + 3 interstitial semi-conductive-covered earths + 1 central pilot (6.0–10 mm²)Semi-conductive elastomer phase & earth barriers; open-weave reinforcement in HD-85-PCP sheathContinuous miners, roof bolters, feeder breakers, and mobile coal-face machines (6 × OD min bend radius)
Type 241SF super-flexible mining cable (241.1 SF to 241.11 SF)1.1/1.1 kV to 11/11 kV; 6–300 mm²3 power cores + 3 interstitial semi-conductive-covered earths + 1 central pilot (6.0–10 mm²)Extra-flexible stranding; semi-conductive elastomer barriers; open-weave reinforced HD-85-PCP sheathTight-radius underground coal reeling, compact cable handlers, and continuous miners (6 × OD min bend radius)
Type 245 mining cable (245.1, 245.3, 245.6)1.1/1.1 kV, 3.3/3.3 kV, 6.6/6.6 kV; 16–300 mm²3 power cores + 3 interstitial earths + 3 central extensible pilots (4.1 mm²)Semi-conductive elastomer phase & earth screens; open-weave braid in HD-85-PCP sheathLongwall shearers and multi-pilot underground coal face machines (6 × OD min bend radius)
Type 245UF ultra-flexible mining cable (245.1 UF, 245.3 UF)1.1/1.1 kV and 3.3/3.3 kV; 50–150 mm²3 ultra-flexible power cores + 3 interstitial earths + 3 central extensible pilots (4.1 mm²)Ultra-fine copper stranding; semi-conductive elastomer screens; reinforced HD-85-PCP sheathHigh-cycle Bretby-style longwall shearer cable chains and tight-bend coal face handlers (6 × OD min bend radius)
Type 260 armoured mining cable (260.1, 260.3, 260.6, 260.11)1.1/1.1 kV to 11/11 kV; 16–300 mm²3 screened power cores + interstitial pilot/earth layout under pliable wire armourAS/NZS 1125 Class 6 copper; tinned-copper/nylon phase screens + galvanized steel pliable wire armourSemi-fixed roadway feeders, stage loaders, and high-crush underground zones (excludes shuttle cars)
Type 275 shuttle car mining cable (Type 275.1)1.1/1.1 kV; 10–95 mm²3 phase cores + 3 interstitial earth cores (6–25 mm²) + 1 central pilot (6.0 mm²)Unscreened elastomeric cradle assembly engineered specifically for high-speed reeling tension; HD-85-PCP sheathDedicated to underground coal shuttle car reeling and trailing drums (30.5–57.9 mm OD; 6 × OD min bend radius)

Continuous miners, roof bolters, and longwall shearers (Type 209, Type 241, Type 241SF, Type 245, Type 245UF)

For continuous miners, road headers, and roof bolters operating at 1.1 kV or 3.3 kV, Australian underground coal mines standardize primarily on Type 209 and Type 241. As detailed in TEBAOFLEX’s Type 209 mining cable selection notes, Type 209 uses tinned-copper/polyamide braid screens over the three power cores as the combined earth conductor (2.5 mm² to 300 mm²), whereas Type 241 replaces the metallic wire braid with semi-conductive elastomer screens and three discrete interstitial earth conductors (6 mm² to 300 mm²). Where machine entries or onboard cable reels impose tighter routing radii and constant flexing, Type 241SF (Super Flexible) upgrades conductor and core lay geometry to reduce torsional stiffness.

On longwall coal faces, the shearer cable travels back and forth inside an articulated Bretby or chain-type cable handler along the armored face conveyor (AFC) while carrying both high-voltage cutter-motor power (1.1 kV, 3.3 kV, or 6.6 kV) and three pilot/control circuits. Type 245 provides three central extensible pilot cores (4.1 mm²) surrounded by three power cores and three semi-conductive-covered interstitial earths. For 1.1 kV and 3.3 kV longwall shearers in 50–150 mm² sizes where standard stranding fatigues prematurely inside the turnaround loop of the cable chain, Type 245UF (Ultra Flexible) uses finer wire stranding (0.20 mm wire diameter on phase and earth conductors) inside an open-weave reinforced HD-85-PCP jacket.

Shuttle cars, hand-held drills, and roadway armour (Type 275, Type 210, Type 240, Type 260)

Shuttle cars represent the most severe dynamic reeling duty in an underground coal mine: the vehicle accelerates rapidly between the continuous miner and the feeder breaker while paying cable on and off a hydraulic reel via a sheave wheel, reversing tension direction at the central anchor point. Both Type 240 and Type 260 datasheets explicitly exclude shuttle-car duty because metallic phase braids and steel wire armour suffer wire fatigue under rapid bidirectional reeling. Instead, AS/NZS 1802 designates Type 275 (1.1/1.1 kV, 10–95 mm²) specifically for underground coal shuttle cars, combining three R-EP-90 power cores, three interstitial earth cores, and one central pilot inside an anti-torsion HD-85-PCP sheath.

At the opposite end of the cross-section scale under AS/NZS 1802, Type 210.1 (1.5 mm² and 2.5 mm², 20.4–22.3 mm overall diameter) supplies 1.1 kV hand-held boring machines and face drills where operators must handle a lightweight cable with a 4 × D minimum bend radius. Where cables lie along crush-prone gate roads, stage loaders, or drift conveyors rather than reeling onto mobile drums, Type 260 (AS/NZS 1802) adds galvanized steel pliable wire armour over the three screened cores (16–300 mm², 1.1–11 kV) to resist falling rock and mechanical impact.

Reeling and trailing mining cables AS/NZS 2802 for open-cut and metalliferous mines (400-series)

When specifying reeling and trailing mining cables AS/NZS 2802 for surface open-cut mines or underground hard-rock metalliferous mines, engineers move from the 200-series to the 400-series. Surface iron ore, coal, copper, and gold mines operate massive electric rope shovels, walking draglines, rotary blast-hole drills, and mobile in-pit crushers fed at 3.3 kV, 6.6 kV, 11 kV, 22 kV, or 33 kV over long bench trailing paths and large vertical or horizontal cable reels.

Class 1 (XR-EP-90 / XHD-85-PCP) vs Class 2 (R-EP-90 / HD-85-PCP) compound duty

A critical engineering distinction inside AS/NZS 2802 is the split between Class 1 and Class 2 insulation and sheathing systems (AS/NZS 3808):

  • Class 2 duty (Type 409, Type 440, and Type 441.1 Class 2): Uses standard R-EP-90 ethylene-propylene rubber insulation and a heavy-duty HD-85-PCP polychloroprene outer sheath. In TEBAOFLEX’s catalog, Type 409 (1.1–22 kV), Type 440 (1.1–22 kV), and low-voltage Type 441.1 Class 2 (1.1/1.1 kV, 6–300 mm² with three uninsulated interstitial earth conductors) are built to Class 2 specifications for general surface and underground metalliferous trailing and reeling duties.
  • Class 1 extra-heavy duty (Type 441 Class 1, Type 450, Type 451, and Type 455): Uses high-modulus cross-linked XR-EP-90 insulation paired with an extra-heavy-duty XHD-85-PCP outer sheath reinforced by open-weave polyaramid braid. Class 1 constructions are specified from 3.3/3.3 kV up to 22/22 kV (Type 441 Class 1), 11/11 kV (Type 455), and 33/33 kV (Type 450 and Type 451) where heavy high-voltage cables drag over blasted bench rock or wind under high radial pressure on multi-layer shovel and dragline reels.
TEBAOFLEX AS/NZS 2802 400-series surface and metalliferous mining cables
TEBAOFLEX AS/NZS 2802 typeDuty class & voltage range ($U_0/U$)Cross-section rangeCore, earth & pilot configurationPhase screen & outer protectionPrimary surface / metalliferous duty
Type 409 mining cable (409.1 to 409.22)Class 2; 1.1/1.1 kV to 22/22 kV2.5–300 mm² (1.1 kV), 16–300 mm² (3.3–6.6 kV), 25–300 mm² (11–22 kV)3 power cores + 1 central extensible pilot; screens serve as earthTinned-copper / polyester composite braid screen; R-EP-90 / HD-85-PCP (6 × OD min bend radius)Surface and metalliferous reeling/trailing equipment where compact OD without interstitial earths is preferred
Type 412 armoured mining power cable (Type 412.1)Armoured LV; 1.1/1.1 kV1.5–300 mm²3 phase cores + 3 interstitial earth/pilot coresR-EP-90 insulation, elastomeric barrier, flexible galvanized steel wire armour, heavy-duty elastomer sheathOpen-cut and underground metalliferous mine semi-fixed feeders, crushers, and rock-fall zones (not for underground coal)
Type 440 mining cable (440.1 to 440.22)Class 2; 1.1/1.1 kV to 22/22 kV50–300 mm² (1.1–22 kV)3 power cores + 3 interstitial pilot cores (6–16 mm²); screens serve as earthComposite tinned-copper / polyester braid screen; R-EP-90 / polyaramid-reinforced HD-85-PCP (6 × OD min bend)Large surface excavators, stackers, reclaimers, and metalliferous machines requiring 3 control/pilot circuits
Type 441.1 Class 2 mining cable (Type 441.1)Class 2; 1.1/1.1 kV6–300 mm²3 power cores + 3 uninsulated interstitial earths + 1 central pilot (6.0–10 mm²)Semi-conductive elastomer phase screens; R-EP-90 insulation; HD-85-PCP sheath (6 × OD min bend radius)Low-voltage open-cut drills, pumps, jumbo rigs, and underground hard-rock trailing cables
Type 441 Class 1 mining cable (441.3, 441.6, 441.11, 441.22)Class 1; 3.3/3.3 kV to 22/22 kV16–300 mm² (3.3–6.6 kV), 25–300 mm² (11–22 kV)3 power cores + 3 semi-conductive-covered interstitial earths + 1 central pilot (6.0–10 mm²)Semi-conductive elastomer phase screens; XR-EP-90 insulation; extra-heavy XHD-85-PCP sheath (6 × OD min bend)High-voltage open-cut electric rope shovels, draglines, and heavy reel-fed excavators
Type 450 Class 1 mining cable (450.3 to 450.33)Class 1; 3.3/3.3 kV to 33/33 kV16–300 mm² (3.3–6.6 kV), 25–300 mm² (11–22 kV), 35–300 mm² (33 kV)3 power cores + 2 interstitial earths (10–70 mm²) + 1 interstitial pilot (10–70 mm²)Composite tinned-copper / polyester phase screens; XR-EP-90 / XHD-85-PCP sheath (6 × OD min bend radius)High-voltage open-cut draglines, large electric shovels, and mobile substation trailing feeds up to 33 kV
Type 451 Class 1 mining cable (451.3 to 451.33)Class 1; 3.3/3.3 kV to 33/33 kV16–300 mm² (3.3–6.6 kV), 25–300 mm² (11–22 kV), 35–300 mm² (33 kV)3 power cores + 2 interstitial earths (10–70 mm²) + 1 reduced-size interstitial pilot (6.0–10 mm²)Composite tinned-copper / polyester phase screens; XR-EP-90 / XHD-85-PCP sheath (6 × OD min bend radius)Same 3.3–33 kV shovel/dragline duty as Type 450 where coupler pins require a smaller 6–10 mm² pilot conductor
Type 455 Class 1 mining cable (455.3, 455.6, 455.11)Class 1; 3.3/3.3 kV to 11/11 kV16–300 mm² (3.3–6.6 kV), 25–300 mm² (11 kV)3 power cores + 2 semi-conductive-covered interstitial earths + 1 interstitial pilot (6.0–10 mm²)Semi-conductive elastomer phase screens; XR-EP-90 / XHD-85-PCP sheath (6 × OD min bend radius)3.3–11 kV reeling and trailing equipment requiring a 2E + 1P interstitial layout with non-metallic phase screens

Selecting between Type 441, Type 450, Type 451, and Type 455 on high-voltage shovels and draglines

On medium- and high-voltage surface mining circuits (3.3 kV to 33 kV), Australian open-cut operations choose between two structural families inside AS/NZS 2802:

  1. 3E + 1 central pilot with semi-conductive phase screens (Type 441 Class 1): Rated from 3.3 kV to 22 kV, Type 441 places one extensible pilot core in the center cradle and three semi-conductive-covered earth conductors in the outer interstices. Because the phase screen is a non-metallic semi-conductive elastomer, Type 441 avoids metallic braid wire breakage when wound onto motor-driven cable reels on electric shovels and blast-hole drills.
  2. 2E + 1 interstitial pilot (Type 450, Type 451, and Type 455): Instead of a central pilot core, these three cables place two earth conductors and one insulated pilot conductor in the three outer interstices around a solid central cradle profile. Type 450 and Type 451 extend all the way to 33/33 kV (Type 450.33 / Type 451.33) using composite tinned-copper/polyester phase screens: choose Type 450 when the specification calls for a full-size interstitial pilot matching the earth core cross-section (10–70 mm²), or choose Type 451 when bolted couplers and pilot relays require a reduced 6.0–10 mm² pilot conductor. Where the mine engineer prefers the same 2E + 1 interstitial pilot geometry at 3.3–11 kV without metallic braid phase screens, Type 455 substitutes semi-conductive elastomer phase barriers.

For 1.1/1.1 kV metalliferous underground drives, declines, and open-cut crusher plants where cables are clipped or laid along rock walls rather than reeled, Type 412 (1.5–300 mm²) provides flexible galvanized steel wire armour over three phase cores and three interstitial earth/pilot cores.

AS/NZS 1972 underground coal mine feeder cables (Type 1, Type 2S, and Type 2S.3)

Not every flexible cable in an underground coal mine winds onto a reeling drum or trails behind a continuous miner. Substation interconnects, district transformer links, stage-loader supplies, and dewatering pump feeders are suspended from roadway roof bolts or relocated between panel moves under AS/NZS 1972.

TEBAOFLEX manufactures two AS/NZS 1972 feeder families to match roadway voltage and flame-propagation class:

  • Mine Feeder Type 1 cable (1.1/1.1 kV, 1.5–300 mm²): Constructed with AS/NZS 1125 Class 5 tinned annealed copper conductors, V-90 PVC core insulation (AS/NZS 3808), individual tinned-copper and polyester yarn composite braid screens (10.2 A/mm² fault current rating), two insulated interstitial pilot cores (1.5–10 mm²), and a heavy-duty 5V-90 PVC outer sheath meeting C3 flame propagation performance (6 × OD minimum bend radius).
  • Mine Feeder Type 2S & Type 2S.3 cable (1.1/1.1 kV for Type 2S in 1.5–300 mm²; 3.3/3.3 kV for Type 2S.3 in 16–300 mm²): Upgrades the insulation to thermoset R-EP-90 EPR (90 °C continuous, 250 °C short-circuit) and replaces the PVC jacket with a black HD-90-CPE chlorinated polyethylene elastomer sheath rated for C1 flame propagation performance (AS/NZS 1660.5.6), while retaining individual tinned-copper/polyester braid screens and two interstitial pilot cores (6 × OD minimum bend radius).

Thermal limits, minimum bending radius, and factory sheath marking verification

Long service life on reeling drums, shuttle-car sheaves, and longwall cable chains depends on respecting the thermal and mechanical limits built into AS/NZS 1802, AS/NZS 2802, and AS/NZS 1972:

  • Conductor and sheath temperature ceilings (AS/NZS 3808): Across both R-EP-90 (Class 2) and XR-EP-90 (Class 1) EPR-insulated mining cables, the maximum continuous conductor operating temperature is 90 °C and the maximum short-circuit conductor temperature (5 s maximum duration) is 250 °C. However, polychloroprene outer sheaths (HD-85-PCP and XHD-85-PCP) have a maximum surface temperature limit of 85 °C. When multiple layer wraps remain parked on a powered reeling drum (such as a shuttle car or shovel reel), current capacity must be derated so accumulated drum heat never pushes the inner cable layers above the 85 °C PCP jacket limit.
  • Minimum installation and reeling bend radius: Standard AS/NZS 1802 and AS/NZS 2802 reeling and trailing cables (Type 209, 241, 241SF, 245, 245UF, 275, 409, 440, 441, 450, 451, 455) specify a minimum bending radius of 6 × OD (six times the overall cable diameter), while light 1.5–2.5 mm² Type 210.1 hand-held drill cables allow 4 × D. Reeling drums, fairlead rollers, and sheave wheels should exceed 6 × OD wherever space allows to avoid kinking interstitial earth cores or elongating the central pilot.
  • Maximum dynamic pulling tension: Calculate dynamic reeling tension solely from the total cross-sectional area of the three phase copper conductors (commonly capped at 15 N/mm² to 20 N/mm² of phase copper depending on reel kinematics), never from the earth screens or pilot cores.

On TEBAOFLEX factory dispatch drums for AS/NZS 1802 and AS/NZS 2802 orders, each production length receives high-contrast embossed or printed sheath markings identifying the voltage rating, AS/NZS type designation, conductor cross-section, manufacturing year, and sequential meter marks (for example, Cable 1.1kV Type 241.1 Mining Cable 35mm² with progressive meter stamps 020m, 025m, 027m, 032m). Sequential meter marking allows mine electrical tradespeople to track remaining drum length during underground flit-plug termination and quickly isolate damaged sections without unwinding the entire reel.

TEBAOFLEX factory dispatch drum of 1.1 kV Type 241.1 35 mm2 mining cable showing sequential meter markings 020m, 025m, 027m and sheath print
TEBAOFLEX dispatch drum and sheath legend for a 1.1/1.1 kV AS/NZS 1802 Type 241.1 35 mm² mining cable with progressive meter marks (020m, 025m, 027m, 032m) for underground length tracking.

What to specify when ordering AS/NZS mining cables

Preparing a complete technical schedule before submitting an enquiry ensures that the quoted AS/NZS 1802, AS/NZS 2802, or AS/NZS 1972 construction matches your mine’s protection relays, couplers, and reeling hardware. Include these five items in your RFQ:

Where automated longwall shearers, continuous miners, or stacker-reclaimers require integrated optical telemetry alongside 1.1/1.1 kV or 1.9/3.3 kV screened power cores, specify: AS/NZS 1802 Type 245F and 241F Electro-Optic Mining Cable.

  1. Standard and exact type designation: State the governing standard (AS/NZS 1802, AS/NZS 2802, or AS/NZS 1972), the exact type number and voltage suffix (such as Type 209.3, Type 241.1, Type 245.3 UF, Type 275.1, Type 441.11, or Type 450.22), and whether SF (Super Flexible), UF (Ultra Flexible), Class 1, or Class 2 construction is required.
  2. Phase, earth, and pilot cross-sections: Nominal power core size (1.5 mm² to 300 mm²), earth arrangement (composite phase screens vs 3 or 2 interstitial earth cores), and pilot core count and size (1 central, 3 interstitial, 3 central extensible, or Type 451 reduced-size interstitial pilot).
  3. Machine duty and reeling geometry: Equipment type (continuous miner, longwall shearer Bretby chain, shuttle car, roof bolter, open-cut electric shovel, dragline, drill, or roadway feeder), minimum drum barrel or sheave diameter, and maximum cable layer count on the reel.
  4. Jacket colour and sheath marking requirements: Standard heavy-duty black HD-85-PCP / XHD-85-PCP / HD-90-CPE or site-specified high-visibility outer jacket colors, plus any custom print legend or sequential meter-marking format.
  5. Cut lengths, drum packaging, and delivery schedule: Individual cut lengths per reel (for example, 100 m, 250 m, or 500 m per flange drum) and total order meterage. Per TEBAOFLEX’s verified company profile (as of August 2026), the minimum order quantity is 50 m for both standard and custom cable constructions, with typical production lead times of 7–45 working days depending on cable type and customization.

Contact TEBAOFLEX with your AS/NZS mining cable specification to request datasheets, overall diameter and weight tables for coupler sizing, and factory quotation support for underground coal, open-cut, and metalliferous mining projects.