
DIRECT FACTORY CATALOG · 31 CONSTRUCTIONS
Oil & Gas Cables (IEEE 1580 Type P, NEK 606 & Wireline)
Oil- and mud-resistant power, control, shielded pair instrumentation, VFD, double-armoured wireline logging, downhole TEC, subsea BOP MUX, and 25 kV flare ignition cables engineered for onshore rigs, offshore platforms, FPSOs, and refineries.

MOQ 50 m (standard & custom) · 7–45 working days · Datasheets & drawings on request
Live Product Catalog


NEK 606 BFOU Cable | P5/P12 Power & Instrumentation

0.6/1kV RFOU Cable for Marine & Offshore NEK 606 Projects

BFOU VFD 1.8/3 kV Offshore Cable — 3C+3E LSZH

Type P Medium Voltage Cable 5kV-15kV Armored and Sheathed

Type P Signal I/O Cable 600V 16 and 14 AWG Armored and Sheathed

Heptacable 7H42, 7J46 & W7 7-Conductor Double-Armoured Wireline Logging Cable (1–1.5 kV DC)

4SSA27 & FIMT-EO Armoured Fiber-Optic & Hybrid Electro-Optical Wireline Logging Cable (DTS / DAS)

TEF, TEC-2C & TEH Tubing-Encapsulated Fiber-Optic & Dual-Core PDHG Downhole Cable (1/4 in)

A304287 & OEH Subsea BOP MUX Control & IWOCS Intervention Electro-Optical Umbilical Cable

TF-TANKCRAWL Cargo Oil Tank (COT), FPSO & Petrochemical Sludge Crawler Antistatic Oil-Resistant Umbilical Cable

Flare Stack Ignition & Igniter Cable 25 kV DC / 10 kV AC, 250°C
ENGINEERING COMPARISON
Oil & Gas Cable Selection Matrix by Environment & Reference Standard
| Construction Family | Reference Standard | Voltage / Temp | Jacket & Armour | Primary Oilfield Duty |
|---|---|---|---|---|
| IEEE 1580 Type P / Type LSX | IEEE 1580 / UL 1309 | 600 V – 15 kV · 110 °C | Mud-resistant thermoset / LSZH, bronze braid | Rig power, top-drive VFD, control & I/O pairs |
| NEK 606 RFOU / BFOU | NEK 606 / IEC 60092 / 60331 | 0.6/1 kV – 1.8/3 kV · 90 °C | SHF2-MUD halogen-free, braided armour (mica on BFOU) | Offshore platforms, FPSOs & mud-exposed decks |
| Wireline Logging (1C / 4C / 7C / FO) | Oilfield double-armoured | 300 V – 1.5 kV DC · up to 260 °C | Counter-helical GIPS / MP35N sour-service armour | Open-hole/cased-hole logging, DTS/DAS & H₂S wells |
| TEC / TEF Downhole Encased | 1/4 in 316L / Alloy 825 tube | Up to 1 kV / Fiber · up to 260 °C | Seamless stainless/Inconel tube + PP/PVDF bumper | Permanent downhole gauges (PDHG) & ESP monitoring |
| Subsea BOP MUX & Tank Crawler | Offshore electro-optical / ATEX | 0.6/1 kV – 3 kV + SM/MM FO | Double steel armour / antistatic oil-resistant PUR | Subsea BOP control, IWOCS & FPSO sludge crawlers |
| 25 kV Flare Stack Ignition | High-temp HV silicone / PTFE | 25 kV DC / 10 kV AC · 250–538 °C | Silicone / glass-braid or fluoropolymer barrier | Refinery & platform flare tips and burner igniters |
VERIFIED EXPORT DELIVERIES
Recent Oil, Gas & Drilling Cable Projects
Documented Taicang factory production, witnessed HV/EPR testing and export shipments (customer names withheld per NDA).

DLO 535 MCM & H07RN-F 16G2.5 Power & Control Bundle for Drilling Rig
Manufactured oil-resistant 2 kV DLO feeder leads alongside flexible 16-core control cables for onshore drilling rig power distribution.
Read Case Study →
Customer Factory Visit: 11 kV & 33 kV EPR Insulation High-Voltage Testing
Client engineers witnessed high-voltage withstand, insulation resistance, and dimensional verification on heavy-duty EPR power cables in Taicang.
Read Case Study →
41.0 mm Offshore Spare Umbilical & Oil-Resistant Deck Cable (300 m)
Custom 300 m offshore composite umbilical engineered to a strict 41.0 mm OD envelope with seawater- and hydrocarbon-resistant outer sheathing.
Read Case Study →ENGINEERING GUIDES & SOLUTIONS
Technical Selection Guides & Industry Solutions
Oil & Gas Cable Selection Guide for Drilling & Offshore
Compare IEEE 1580 Type P, NEK 606 mud resistance, hazardous-area zoning, and fire survival criteria.
ENGINEERING GUIDERFOU vs BFOU Cable: NEK 606 Designations Explained
Decode NEK 606 letter codes, mica fire-barrier differences (IEC 60331), and SHF2-MUD outer jackets.
ENGINEERING GUIDEATEX Cable Requirements for Zone 1 & Zone 2 Areas
Clarify IEC 60079-14 installation rules, gas-tight cable glands, armouring, and what cables actually require.
ENGINEERING GUIDEOil-Resistant Cable Ratings: PR I vs PR II & Mud Exposure
Understand IRM 902/903 oil immersion tests, ester/mineral drilling mud swelling, and thermoset vs PUR jackets.
SOLUTION HUBOil, Gas & Petrochemical Cable Solutions Hub
System-level cable architecture across upstream drilling rigs, midstream pipelines, and downstream refineries.
SOLUTION HUBMarine & Offshore Vessels and Platforms Hub
Coordinated shipboard IEC 60092, NEK 606 offshore, and subsea ROV cable supply from one factory.
DIRECT MANUFACTURER · TAICANG, JIANGSU
Built to Order in Our Taicang Factory — ISO 9001:2015 Quality System
TEBAOFLEX (est. 2014) manufactures oil-resistant power, IEEE 1580 Type P, NEK 606 mud-resistant RFOU/BFOU, double-armoured wireline logging, and downhole TEC cables in Taicang, China (~150,000 km annual capacity, exporting to 20+ countries). ISO 9001:2015 production (244-24-QI-17425-R0-Q); witnessed FAT, spark/HV testing, and third-party inspection available per order. Active product certs: UL 62 ZJCZ (UL-US-2449012-4) & VDE 40060056 on covered cord ranges.



TECHNICAL FAQ
Common Oil & Gas Cable Specification Questions
What is the difference between IEEE 1580 Type P and NEK 606 RFOU/BFOU cables?
IEEE 1580 Type P is the North American / API-aligned flexible thermoset rig cable family (600 V–15 kV, 110 °C EPR/XLPO, bronze braid armour optional) built for oil-drilling rigs and land/offshore platforms. NEK 606 RFOU (flame-retardant) and BFOU (mica-taped fire-resistant to IEC 60331) follow the Norwegian/European halogen-free SHF2-MUD standard engineered specifically for continuous hydrocarbon and synthetic drilling-mud immersion on offshore platforms and FPSOs.
Do oil & gas cables for ATEX Zone 1 or Zone 2 require an ATEX certificate on the cable itself?
No. Under ATEX Directive 2014/34/EU and IEC 60079-14, electrical cables are passive wiring components and are not ATEX-certified individually; compliance depends on certified Ex d/Ex e cable glands, circular/bedding geometry for gas-tight sealing, flame-retardant/mud-resistant jackets, and proper armour grounding.
Can TEBAOFLEX manufacture custom double-armoured wireline logging and sour-service (H₂S) cables?
Yes. We manufacture monoconductor, 4-conductor quad, 7-conductor heptacable, and fiber-optic/electro-optical (DTS/DAS) wireline cables with counter-helical galvanized improved plow steel (GIPS) or corrosion-resistant alloy armour for high-temperature (up to 260 °C) and H₂S sour-service wells.
When should I choose a TEC (Tubing-Encapsulated Cable) over an armoured downhole wireline?
Choose TEC / TEF when the cable is clamped permanently to production tubing for downhole pressure/temperature gauges (PDHG) or ESP monitoring, where a seamless 1/4-inch 316L stainless or Alloy 825 metal tube must block well fluids and gas ingress for years. Choose double-armoured wireline when the cable is repeatedly run on a winch drum under high tensile load.
What are TEBAOFLEX’s MOQ, lead time, and inspection options for oil & gas cable orders?
Standard and custom MOQ starts at 50 m per construction, with typical factory lead times of 7–45 working days depending on armouring, metallic tubing, or compound tooling. Production runs under ISO 9001:2015 (244-24-QI-17425-R0-Q), with routine HV/spark tests and optional witnessed FAT or third-party inspection arranged per order.
DIRECT FACTORY ENGINEERING DESK
Request Datasheet, Cross-Reference or Drum Quote
Send your Type P / NEK 606 designation, wireline OD/breaking strength, voltage, or hazardous-area spec. Our engineers confirm construction, MOQ (from 50 m), and lead time (7–45 working days) in writing.
Helpful details for a faster engineering reply:
- Cable family & reference standard (IEEE 1580 Type P / LSX, NEK 606 RFOU/BFOU, Wireline, TEC, or 25 kV flare)
- Voltage rating, conductor size (AWG/kcmil or mm²), pair/core count, and required armour or metal tube alloy
- Exposure environment (drilling mud, H₂S sour gas, Zone 1/2, subsea pressure, max operating temperature)
- Cut/drum length (MOQ 50 m), witness FAT / inspection requirement, and destination port
Selected constructions (auto-filled in form):
- Click “+ Add to enquiry” on any product card above to attach models automatically.

